Automatic start control circuit informed by long power outage and incoming call
Source: InternetPublisher:elleny Keywords: Control circuit dynamic control BSP electric motor Updated: 2021/07/13
The circuit for the motor to automatically restart after a long power outage is shown in Figure 4-37. During normal starting, the switch SA on the platform, the power supply passes through
the moving contact of the intermediate relay KA, so that the energization delay time relay KT is electrically closed.
After delay, its delayed closing moving contact closes, causing the contactor to close.
KM gets electrical pull-in, its main contact closes, starts the motor, its auxiliary contact
closes and self-locks, and the other auxiliary contact closes, so that KA gets electrical pull-in.
The dynamic breaking contact of KA is disconnected, causing KT to lose power and release, cutting off the time relay
.
If a power outage occurs while the motor is running, the KM will be released due to loss of power,
its main contacts will be disconnected, the motor will stop, and its auxiliary contacts will also be disconnected. When KA
loses power and is released, its moving contact is reset and closed, that is, the entire circuit except SA
returns to its original static state.
No matter how long the power outage lasts, as long as the next call comes, the time relay
KT will get the electric suction table. After a delay, its delay contact will close, causing the KM to get the electric suction and self-locking, and the motor will start running. Obviously,
after another call, the motor will start automatically as a normal start.
- Manual automatic air compressor control circuit
- Motor control circuit for starting and running without phase loss
- Design and principle analysis of practical electric curtain remote control device
- Design and analysis of wire control circuit
- Do-it-yourself trial production of phase failure protection device
- Homemade short circuit alarm device
- Remote anti-theft alarm via telephone
- An analysis of the working principle of a kg316t time-controlled switch circuit
- CD4017 simple and easy to make zero-crossing power regulation circuit
- Household flower pot automatic watering device
- Set timing circuit when power is on
- Excellent performance household inverter power supply circuit
- Inpatient pager circuit
- High-efficiency speaker circuit for rural stage
- Fish pond oxygenation reminder circuit
- Rural vegetable greenhouse lighting circuit
- Series crystal oscillator
- Differential Amplifier Circuit
- Motorcycle flash light circuit
- Various signal generator circuits