Home > Control Circuits >Motor Control > Intermittent cycle control start and stop circuit 7b

Intermittent cycle control start and stop circuit 7b

Source: InternetPublisher:ohahaha Keywords: potentiometer power saving Updated: 2021/04/24

82. Intermittent cycle<strong>control</strong> start and stop<strong>circuit</strong> Part 7b.gif

The circuit is shown in Figure 3-82. It uses 555 time base integrated circuit A to realize automatic control of start, stop and cycle of the motor.
Adjust the potentiometers RPi and RPz to change the motor running and stopping time respectively.