宋元浩

[Unverified] bm3451-6 to 8 string protection board

 
Overview

bm3451 cascades 6-8 string protection boards, which can be configured into 3+3, 3+4, 3+5 modes by short-circuiting solder joints. Please be careful when building the board without verification.

Correction: When ntc is 100k, the corresponding rtrh is 54k, and when ntc is 10k, the corresponding rtrh is 7k. The schematic diagram is wrong and I didn’t have time to change it. I suggest you be careful.