Why choose explosion-proof solenoid valve
1. Safety of explosion-proof solenoid valve
1. Corrosive media: Plastic King solenoid valves and all stainless steel are recommended; for highly corrosive media, isolation diaphragm type must be selected. For example, CD-F.Z3CF. For neutral media, it is also recommended to use solenoid valves with copper alloy as the valve shell material, otherwise, rust chips often fall off the valve shell, especially in occasions where the operation is not frequent. Ammonia valves cannot be made of copper.
2. Explosive environment: products with corresponding explosion-proof grade must be selected. Waterproof and dustproof products should be selected for outdoor installation or dusty occasions.
3. The nominal pressure of the solenoid valve should exceed the maximum working pressure in the pipe.
2. Reliability of explosion-proof solenoid valve
1. Working life: This item is not included in the factory test items, but belongs to the type test items. To ensure the quality, you should choose the famous brand products of regular manufacturers.
2. Working mode: divided into three types: long-term working mode, repeated short-time working mode and short-time working mode. Our company's conventional products are all long-term working mode, and the coil is allowed to be powered on for a long time. For the situation where the valve is open for a long time and only closed for a short time, it is advisable to use a normally open solenoid valve. When used in short-time working mode and the batch is large, special orders can be made to reduce power consumption.
3. Working frequency: When the operating frequency requirement is high, the structure should preferably be a direct-acting solenoid valve, and the power supply should preferably be AC.
4. Action reliability
Strictly speaking, this test has not been formally included in the professional standards of solenoid valves in my country. To ensure quality, you should choose brand-name products from regular manufacturers. In some occasions, the number of actions is not large, but the reliability requirements are very high, such as fire protection and emergency protection, so you must not take it lightly. It is particularly important to use two double insurances in succession.
3. Economical performance of explosion-proof solenoid valve
It is one of the criteria for selection, but it must be economical on the basis of safety, applicability and reliability.
Economy is not just about the selling price of the product, but also its function and quality as well as the cost of installation, maintenance and other accessories.
More importantly, the cost of a solenoid valve in the entire automatic control system and even in the production line is negligible. If you try to save a little and make the wrong choice, the damage will be huge.
Selection basis of explosion-proof solenoid valve
1. Select the solenoid valve according to the pressure parameters: principle and structure variety
1) Nominal pressure: This parameter has the same meaning as other common valves and is determined according to the nominal pressure of the pipeline;
2) Working pressure: If the working pressure is low, the direct-acting or step-by-step direct-acting principle must be selected; when the minimum working pressure difference is above 0.04Mpa, the direct-acting, step-by-step direct-acting and pilot-operated types can be selected.
2. Electrical selection: The voltage specifications should preferably be AC220V and DC24, which is more convenient.
3. Choose according to the duration of continuous working: normally closed, normally open, or continuously powered
1) When the solenoid valve needs to be opened for a long time and the duration is longer than the closing time, the normally open type should be selected;
2) If the opening time is short or the opening and closing time is not much, choose the normally closed type;
3) However, for some working conditions used for safety protection, such as furnace and kiln flame monitoring, the normally open type cannot be selected, and the type that can be powered on for a long time should be selected.
4. Select auxiliary functions according to environmental requirements: explosion-proof, non-return, manual, waterproof fog, water spray, diving. Select the solenoid valve according to pipeline parameters: diameter specification (DN)
Previous article:Common parameter setting methods for frequency converter
Next article:Explosion-proof solenoid valve technical parameters_Solenoid valve explosion-proof grade standard
- Popular Resources
- Popular amplifiers
- Huawei's Strategic Department Director Gai Gang: The cumulative installed base of open source Euler operating system exceeds 10 million sets
- Analysis of the application of several common contact parts in high-voltage connectors of new energy vehicles
- Wiring harness durability test and contact voltage drop test method
- Sn-doped CuO nanostructure-based ethanol gas sensor for real-time drunk driving detection in vehicles
- Design considerations for automotive battery wiring harness
- Do you know all the various motors commonly used in automotive electronics?
- What are the functions of the Internet of Vehicles? What are the uses and benefits of the Internet of Vehicles?
- Power Inverter - A critical safety system for electric vehicles
- Analysis of the information security mechanism of AUTOSAR, the automotive embedded software framework
Professor at Beihang University, dedicated to promoting microcontrollers and embedded systems for over 20 years.
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
- Keysight Material Dielectric Constant Test Method - Just Read the Content
- Sound pressure, sound intensity and sound power
- Proteus MSP430 MCU simulation example 8-2-bit digital tube countdown
- The TouchGFX Designer is a real pain
- How to implement analog serial communication with TI MSP430
- ffmpeg port on at91sam9261ek
- How to understand the automatic reload function of the timer
- Things to note when using peelable adhesive
- Last day! TI Live Broadcast with Prizes | Application of Precision ADC in Transmitters
- Renesas CPK-RA6M4 development board evaluation + SHT20 sensor reading data