SynQor® launches new high-voltage DC adjustable output UPS power supply (UPS-1250W series)


  • 1250 W DC adjustable output voltage UPS (25 V~ 325 V DC, maximum output current 6 A)

  • Full power output voltage 210 ~325 Vdc 

  • Online dual conversion, built-in battery hot-swappable

  • Fully sealed, impact-proof, weatherproof structure

  • 1U rack is ultra-light (about 15KG)


image.png


SynQor announced the launch of a new isolated uninterruptible UPS power supply, which can output adjustable DC high voltage at full power; the UPS can provide 25 V~325 V adjustable DC output through the DC3 port, and the maximum power can reach 210~325V DC output. 1250W (the user can configure the output voltage and current arbitrarily) . Users can increase the output power by connecting the DC3 output of multiple units in parallel or in an N+M redundant configuration. The UPS can also be configured to output high voltage on DC3 while providing 24 V or 28 V DC output (maximum power 1250 W) at the DC2 port, and 12, 15, 24, 28, 40 or 50V DC output (maximum power 500 W) at the DC1 port. W). The input of this UPS power supply can be either a wide-range AC input or a 28 V DC input, and it can provide up to three different fully isolated DC output voltages.


Designed specifically for military and aerospace applications, this UPS is compact, ultra-lightweight, fully isolated, rugged and durable; for battery charging applications, it can be implemented with a constant current function. It is designed to withstand harsh electrical, shock/vibration and other environmental conditions; the power pack is provided by an advanced, efficient, ultra-light, compact, sealed lithium polymer battery pack.


SynQor's new battery pack performs significantly better than other similar solutions on the market. It also has a variety of easy-to-operate functions, such as the SNMP Ethernet basic module, which can be configured through a friendly network interface, and can also realize real-time remote monitoring through email, thereby issuing important system event warnings to users and monitoring stations. Another feature allows wide input AC applications (47-800 Hz). These UPSs feature a droop current sharing option in the DC2 port, allowing load sharing and N+M redundant configurations between multiple UPS units at low output voltages. In addition, an extended battery pack model is also available in a 2U chassis, extending battery runtime from 10 minutes to 24 minutes.


Features:


High voltage DC adjustable output 25 Vdc ~325 Vdc

Adjustable current 0 ~6 A

Built-in load sharing and redundant N+M functions

Battery full power running time >24 minutes

Universal AC input: 80-265 VAC; 47-65 Hz or 47-800 Hz

1U high rack mount unit 431.8x565.15x43.9mm (17” x 22.25” x 1.73”)

Optional DC1 output, 12, 15, 24, 28, 40, 50 Vdc

Optional DC2 output 24, 28 Vdc (replaces DC input)

Optional DC input (replaces DC2 output)


Comply with specifications:


Military Standard-461F

Military Standard-704F

Military Standard-810G

Military Standard-1275D

Military Standard-1399-300B


Keywords:SynQor Reference address:SynQor® launches new high-voltage DC adjustable output UPS power supply (UPS-1250W series)

Previous article:Arita Power Supply • Releases airborne non-isolated three-phase power factor correction module Y- MIPC-270-115-270 FP
Next article:COSEL launches industrial power supply with higher reliability

Recommended ReadingLatest update time:2024-11-16 09:24

Gezhouba Equipment Company successfully developed high-efficiency dynamic UPS power system products
On May 15, the high-efficiency dynamic UPS power system product jointly developed by the Energy Heavy Industry and Gas Turbine Company of China Energy Construction Gezhouba Equipment Company passed the customer's factory inspection, which marked the success of the first high-efficiency dynamic UPS power system produ
[New Energy]
New development trend of UPS system communication in computer room in the future
In the data center, UPS is a necessary power supply safety device. How to monitor the working status of UPS battery wirelessly? This article introduces a new idea. 1. UPS UPS (Uninterruptible Power System/Uninterruptible Power Supply), an uninterruptible power supply system, can quickly convert the stored DC powe
[Power Management]
New development trend of UPS system communication in computer room in the future
Latest Power Management Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号