The four-element infrared detector uses photosensitive elements, and the alarm is triggered only when each detector detects a signal. It has stronger anti-false alarm capabilities and better detection performance than ordinary dual-element infrared and curtain-type detectors. It has the ability to identify the intrusion direction. If the user breaks into the warning area from the inside to the outside, the alarm will not be triggered. Only illegal intrusions from the outside will trigger the alarm, which greatly facilitates the user's activities in the fortified warning area without triggering the alarm system, truly achieving "zero false alarm". And it has very few peripheral devices, saving space, cost and debugging time, and improving the reliability of the whole machine.
l Infrared acquisition module
The infrared detector is a radiation energy converter, which is mainly used to convert the received infrared radiation energy into electrical energy, heat energy and other forms of energy that are easy to measure or observe. The dual-element detector contains two units, which are connected with reverse polarity to the common FET output, but the quad detector contains four units, two outputs, and the two independent channels enable signal processing to avoid false alarms. It is characterized by low noise, high responsiveness, excellent common mode balance, dual unit type, various filter windows for broadband or narrowband applications, single or dual channel devices, and unit devices with thermal compensation. The quad infrared detector model Lhi807 is used here, and its reliability and other indicators are far higher than the dual detector.
2 Signal processing module The
quad infrared detector provides multiple segmented detection areas. An alarm signal is generated by the accumulation of all infrared energy in each area. It divides a human target into 4 to 8 areas to produce clear and strongest signals to achieve stable detection. Local temperature changes, such as those caused by mice and curtains, only affect one or two areas at the same time, thereby generating a smaller detection signal. These signals are then analyzed by the signal processing circuit to obtain more accurate detection and filter out false alarm signals, as shown in Figure 1.
Signal sampling affects the actual application value of the circuit for the accuracy of signal processing. Here, Ni's TI5000 series DSP5402 is used, which is packaged in a 68-pin PLCC package and has a 10-bit A/D converter inside. Therefore, the A/D converter is omitted in the hardware circuit, and a higher resolution can be obtained.
3 Overall hardware circuit
The hardware part of the system is mainly composed of the front-end input circuit, sampler signal processing and peripheral circuits. The overall circuit is shown in Figure 2.
The PIR sensing signal is amplified at the second level, and then compared with the window voltage to determine whether it is triggered. If it is, it outputs a high level. At this time, the timer is controlled to start timing and enter the delay state. When the PIR detection signal time is greater than 768T (clock cycle), it outputs a high level to prevent false triggering. The internal output controller is equivalent to the function of an AND gate. Only when the photoresistor CDS detects the timing output and the zero-crossing detection is high at the same time, it will output a positive pulse to control the thyristor action. The photosensitive element cadmium sulfide CDS is connected to the internal Schmitt trigger. During the day, the CDS resistance is low, the Schmitt output is low, and the output is inhibited; on the contrary, when the PIR works, the CDS does not work, that is, the I/O pin detects that the CDS outputs a low level. Due to the role of RE200B zero-crossing detection, a standard starting point is the zero-crossing voltage. When the l, 2, and 3 pins are high at the same time, the 11th pin outputs a positive pulse to control the operation of the peripheral circuit. The 15-pin TCI is the timing clock, and the 19-pin TB is the system clock. The time setting is: F=(1±0.2)/1.1RCo. The load can continue to work if the human body has a slight movement in the sensing range of the switch. When the human body is stationary for more than the delay time, the switch will automatically turn off. Once the human body moves, the load will automatically turn on again. Since the circuit adopts zero-crossing technology, it is often on and off, which has little effect on the load. When this switch is installed during the day, the light bulb will flash 3 times and then go out, indicating that the initialization is completed and the normal monitoring state is entered. When this switch is installed at night, the load will work immediately, and the load will automatically turn off after the person leaves.
4 Performance test
The simulation software Matlab was used to simulate the day and night conditions respectively, and the simulation diagrams are shown in Figures 3 and 4. Among them, Figure 3 is the simulation result of the binary pyroelectric infrared signal processor, and Figure 4 is the simulation result of the quaternary pyroelectric infrared signal processor. It can be seen from the figure that the quaternary pyroelectric infrared has a better response speed.
5 Conclusion
With the improvement of people's safety awareness, more and more people are investing in the research of safety technology, and the application of multi-element infrared detector sensors has gradually become a hot topic. Based on the comprehensive discussion of pyroelectric infrared sensors, the hardware structure design of the four-element pyroelectric infrared signal processor is given, and finally the detailed data simulation is carried out using Matlab software, so it can be predicted that the development of this type of system will surely promote the industrialization of safety technology faster and have certain economic significance.
Reference address:Design and implementation of a high performance infrared signal detection switch
l Infrared acquisition module
The infrared detector is a radiation energy converter, which is mainly used to convert the received infrared radiation energy into electrical energy, heat energy and other forms of energy that are easy to measure or observe. The dual-element detector contains two units, which are connected with reverse polarity to the common FET output, but the quad detector contains four units, two outputs, and the two independent channels enable signal processing to avoid false alarms. It is characterized by low noise, high responsiveness, excellent common mode balance, dual unit type, various filter windows for broadband or narrowband applications, single or dual channel devices, and unit devices with thermal compensation. The quad infrared detector model Lhi807 is used here, and its reliability and other indicators are far higher than the dual detector.
2 Signal processing module The
quad infrared detector provides multiple segmented detection areas. An alarm signal is generated by the accumulation of all infrared energy in each area. It divides a human target into 4 to 8 areas to produce clear and strongest signals to achieve stable detection. Local temperature changes, such as those caused by mice and curtains, only affect one or two areas at the same time, thereby generating a smaller detection signal. These signals are then analyzed by the signal processing circuit to obtain more accurate detection and filter out false alarm signals, as shown in Figure 1.
Signal sampling affects the actual application value of the circuit for the accuracy of signal processing. Here, Ni's TI5000 series DSP5402 is used, which is packaged in a 68-pin PLCC package and has a 10-bit A/D converter inside. Therefore, the A/D converter is omitted in the hardware circuit, and a higher resolution can be obtained.
3 Overall hardware circuit
The hardware part of the system is mainly composed of the front-end input circuit, sampler signal processing and peripheral circuits. The overall circuit is shown in Figure 2.
The PIR sensing signal is amplified at the second level, and then compared with the window voltage to determine whether it is triggered. If it is, it outputs a high level. At this time, the timer is controlled to start timing and enter the delay state. When the PIR detection signal time is greater than 768T (clock cycle), it outputs a high level to prevent false triggering. The internal output controller is equivalent to the function of an AND gate. Only when the photoresistor CDS detects the timing output and the zero-crossing detection is high at the same time, it will output a positive pulse to control the thyristor action. The photosensitive element cadmium sulfide CDS is connected to the internal Schmitt trigger. During the day, the CDS resistance is low, the Schmitt output is low, and the output is inhibited; on the contrary, when the PIR works, the CDS does not work, that is, the I/O pin detects that the CDS outputs a low level. Due to the role of RE200B zero-crossing detection, a standard starting point is the zero-crossing voltage. When the l, 2, and 3 pins are high at the same time, the 11th pin outputs a positive pulse to control the operation of the peripheral circuit. The 15-pin TCI is the timing clock, and the 19-pin TB is the system clock. The time setting is: F=(1±0.2)/1.1RCo. The load can continue to work if the human body has a slight movement in the sensing range of the switch. When the human body is stationary for more than the delay time, the switch will automatically turn off. Once the human body moves, the load will automatically turn on again. Since the circuit adopts zero-crossing technology, it is often on and off, which has little effect on the load. When this switch is installed during the day, the light bulb will flash 3 times and then go out, indicating that the initialization is completed and the normal monitoring state is entered. When this switch is installed at night, the load will work immediately, and the load will automatically turn off after the person leaves.
4 Performance test
The simulation software Matlab was used to simulate the day and night conditions respectively, and the simulation diagrams are shown in Figures 3 and 4. Among them, Figure 3 is the simulation result of the binary pyroelectric infrared signal processor, and Figure 4 is the simulation result of the quaternary pyroelectric infrared signal processor. It can be seen from the figure that the quaternary pyroelectric infrared has a better response speed.
5 Conclusion
With the improvement of people's safety awareness, more and more people are investing in the research of safety technology, and the application of multi-element infrared detector sensors has gradually become a hot topic. Based on the comprehensive discussion of pyroelectric infrared sensors, the hardware structure design of the four-element pyroelectric infrared signal processor is given, and finally the detailed data simulation is carried out using Matlab software, so it can be predicted that the development of this type of system will surely promote the industrialization of safety technology faster and have certain economic significance.
Previous article:Dual motor wireless remote control circuit
Next article:Thirteen things not to do when replacing a fuse in an electrical circuit
- Popular Resources
- Popular amplifiers
Latest Power Management Articles
- MathWorks and NXP Collaborate to Launch Model-Based Design Toolbox for Battery Management Systems
- STMicroelectronics' advanced galvanically isolated gate driver STGAP3S provides flexible protection for IGBTs and SiC MOSFETs
- New diaphragm-free solid-state lithium battery technology is launched: the distance between the positive and negative electrodes is less than 0.000001 meters
- [“Source” Observe the Autumn Series] Application and testing of the next generation of semiconductor gallium oxide device photodetectors
- 采用自主设计封装,绝缘电阻显著提高!ROHM开发出更高电压xEV系统的SiC肖特基势垒二极管
- Will GaN replace SiC? PI's disruptive 1700V InnoMux2 is here to demonstrate
- From Isolation to the Third and a Half Generation: Understanding Naxinwei's Gate Driver IC in One Article
- The appeal of 48 V technology: importance, benefits and key factors in system-level applications
- Important breakthrough in recycling of used lithium-ion batteries
MoreSelected Circuit Diagrams
MoreDaily News
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
Guess you like
- Free application: ST sensor kit SensorTile.box worth 350 yuan
- EEWorld Circuit Diagram Channel has a new version and is now online, come and experience it now!
- Reduction Operator Introduction
- [SAMR21 New Gameplay] 32. CPU-related functions
- WiFi 7 specs, features and release date
- 【LuatOS-ESP32】Create a new hello world project
- C2000 Power-on Boot Mode Analysis
- Espressif ESP32-S2-Kaluga-1 Review Summary
- EEWORLD University Hall----Electromagnetic Compatibility Principles and Design
- MSP430 realizes access card function (RFID) through RC522