Analysis based on improving the performance of bridgeless PFC high-performance power supply design

Publisher:SerendipityLoveLatest update time:2012-03-18 Source: OFweek Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

As efficiency requirements continue to grow, many power supply manufacturers are turning their attention to bridgeless power factor correction (PFC) topologies. Generally speaking, bridgeless PFC can reduce conduction losses by reducing the number of semiconductor components in the line current path. Although the concept of bridgeless PFC has been proposed for many years, its implementation difficulty and control complexity have prevented it from becoming a mainstream topology.

As some low-cost, high-performance digital controllers designed specifically for power supplies are available, more and more power supply companies are beginning to choose these new digital controllers for PFC design. Compared with traditional analog controllers, digital controllers have many advantages, such as programmable configuration, nonlinear control, lower number of components, and most importantly, the ability to implement complex functions (which are usually difficult to achieve with analog methods).

Most of today's digital power controllers (such as TI's Fusion Digital Power Controller UCD30xx) provide many integrated power control peripherals and a power management core, such as digital loop compensators, fast analog-to-digital converters (ADCs), high-resolution digital pulse width modulators (DPWMs) with built-in dead time, and low-power microcontrollers, etc. They are all beneficial to complex high-performance power designs such as bridgeless PFC.

Digitally controlled bridgeless PFC

Among other bridgeless PFC topologies, Figure 1 is an example of a bridgeless PFC that has been widely adopted in the industry. It has two DC/DC boost circuits, one consisting of L1, D1 and S1, and the other consisting of L2, D2 and S2. D3 and D4 are slow recovery diodes. The input AC voltage is measured by detecting the line and neutral voltages respectively with reference to the internal power ground. By comparing the detected line and neutral signals, the firmware can know whether it is a positive half cycle or a negative half cycle. In a positive half cycle, the first DC/DC boost circuit (L1-S1-D1) is effective, and the boost current returns to the AC neutral point through diode D4; in a negative half cycle, the second DC/DC boost circuit (L2-S2-D2) is effective, and the boost current diode returns to the AC line through D3. A digital controller such as UCD3020 is used to control this bridgeless PFC.

Figure 1 Digitally controlled bridgeless PFC

The bridgeless PFC is basically composed of two phase boost circuits, but only one phase is active at any time. Compared with the traditional single-phase PFC using the same power devices, the switching losses of the bridgeless PFC and the single-phase PFC should be the same. However, the bridgeless PFC current only passes through one slow diode (D4 in the positive half cycle and D3 in the negative half cycle) at any time, not two. Therefore, the efficiency improvement depends on the difference in conduction loss between one diode and two diodes. In addition, the efficiency of the bridgeless PFC can be further improved by fully turning on the non-current switch. For example: in a positive half cycle, S2 can be fully turned on while S1 is controlled by the PWM signal. When the flowing current is lower than a certain value, the voltage drop of MOSFET S2 may be lower than that of diode D4, so the return current partially or completely flows through L1-D1-RL-S2-L2 and then returns to the AC source. In this way, the conduction loss is reduced and the circuit efficiency can be improved (especially under light load conditions). Similarly, in a negative half cycle, S1 is fully turned on when S2 switches. Figure 2 shows the control waveforms of S1 and S2.

Figure 2 PWM waveform of bridgeless PFC

Adaptive bus voltage and switching frequency control

Traditionally, efficiency was specified at full load for both high and low line. Now, most applications such as computing servers and telecom power supplies require that efficiency should meet standard specifications in the 10%-50% load range in addition to full load. In most AC/DC applications, the system has a PFC and a downstream DC/DC stage, so we measure efficiency based on the entire system. If we want to improve the total system efficiency at light load, one way is to reduce the PFC output voltage and switching frequency. This requires knowledge of the load, which is usually done by measuring the output current using some additional circuitry. However, with digital controllers, this additional circuitry is no longer required. When the input AC voltage and DC output voltage are the same, the output current is proportional to the voltage loop output. Therefore, if we know the output of the voltage loop, we can adjust the frequency and output voltage accordingly. With digital controllers, the voltage loop is implemented in firmware. Its output is known, so it is very easy to implement this feature and the cost is much lower than using analog methods.

Current sensing via current transformer

One of the challenges of bridgeless PFC is how to sense the rectified AC current. As mentioned earlier, the AC return current (partially or entirely) may flow through the non-current switch instead of the slow diodes D3/D4. Therefore, the method of using a shunt to sense the current in the ground path (usually used in traditional PFC) is no longer applicable. Instead, a current transformer (CT) is used for sensing, one for each phase (Figure 1). The outputs of the two current transformers are rectified and combined to produce the current feedback signal. Since only one current transformer has a rectified output signal at any time, even if they are combined, there is only one feedback current signal at any time.

Figure 3 Detection current waveform in continuous conduction mode

Figure 4 Detection current waveform in discontinuous conduction mode

As shown in Figures 3 and 4, since the converter is placed directly above the switch, it only detects the switch current (only the rising part of the inductor current). When digital control is implemented, the switch current signal is measured in the middle of the PWM on-time Ta. It is an instantaneous value and is represented by Isense in Figures 3 and 4. The measured switch current Isense is equal to the average PFC inductor current only when the current is a continuous current (Figure 3). When the current becomes a discontinuous state as shown in Figure 4, Isense will no longer be equal to the average PFC inductor current. In order to calculate the average inductor current, the relationship between the midpoint detection current Isense and the average inductor current in a switching cycle should be established, and this relationship should apply to both continuous conduction mode (CCM) and discontinuous conduction mode (DCM).

For a boost converter operating in steady state, the secondary voltage of the boost inductor should be balanced in each switching cycle:

Where Ta is the current rise time (PWM on time), Tb is the current fall time (PWM off time), VIN is the input voltage, VO is the output voltage, and it is assumed that all power devices are in ideal state.

As can be seen from Figures 3 and 4, we can calculate the average inductor current Iave based on Isense:

Where T is the switching period.

Combining equations (1) and (2), we can obtain:

By using equation (3), the average inductor current Iave is expressed as the instantaneous switch current Isense. The desired currents Iave and Isense are the current references for the current control loop. After the actual instantaneous switch current is detected, it is compared with the reference, and the error is sent to a fast error ADC (EADC). Finally, the digitized error signal is sent to a digital compensator to close the current control loop.

Dynamically Adjustable Loop Compensator

Total harmonic distortion (THD) and power factor (PF) are two very important criteria for determining PFC performance. A good loop compensator should have good THD and PF. However, since the input range of PFC is very wide, it can extend from 80Vac to up to 265Vac. Therefore, a compensator with high performance on low-voltage lines may not work well on high-voltage lines. The best way is to adjust the loop compensator accordingly according to the input voltage. This may be an impossible task for analog controllers, but it can be easily achieved for some digital controllers (such as UCD3020).

The digital compensator in this chip is a digital filter that consists of a second-order infinite impulse response (IIR) filter cascaded with a first-order IIR filter. The control parameters, the so-called coefficients, are stored in a set of registers. This register set is called a bank. There are two such banks, and they can store different coefficients. At any time, only one bank's coefficients are valid and used for compensation calculations, while the other is inactive. The firmware can always load new coefficients to the inactive bank. During PFC operation, the coefficient banks can be swapped at any time to allow the compensator to use different control parameters to adapt to different operating conditions.

Figure 5 VIN and IIN waveforms of low-voltage line (VIN=110V, load=1100W, THD=2.23%, PF=0.998)

With this flexibility, we can store two different coefficient sets (one for low line and another for high line) and swap the coefficients based on the input voltage. The loop bandwidth, phase margin, and gain margin can be optimized at both low and high line. Using this dynamically adjusted control loop coefficient and using firmware to compensate for possible converter offsets, THD and PF can be greatly improved. Figures 5 and 6 are based on test results of a 1100W bridgeless PFC, with a THD of 2.23% on low line and 2.27% on high line, while PF is 0.998 and 0.996 respectively.

Figure 6 VIN and IIN waveforms of high voltage line (VIN=220V, load=1100W, THD=2.27%, PF=0.996)

Improve PF at light load

Every PFC has an electromagnetic interference (EMI) filter at the input. The X-capacitors of the EMI filter cause the AC input current to lead the AC voltage, which affects the PF. At light load and high line voltage, the situation becomes even worse: the PF can hardly meet the strict specifications. To increase the PF at light load, we need to force the current to lag accordingly. How can we achieve this?

Figure 7: Measured VIN with no delay

As we know, the PFC current control loop constantly tries to force the current to match its reference. This reference is basically an AC voltage signal, just with a different magnitude. Therefore, if we can delay the voltage sense signal and use the delayed voltage signal for current reference generation, we can delay the current to match the AC voltage signal, thus improving the PF. This is difficult for an analog controller, but can be achieved with digital control in just a few lines of code.

Figure 8 The measured VIN is delayed by 300us

First, the input AC voltage is measured by the ADC. The firmware reads the measured voltage signal, adds some delay, and then uses the delayed signal to generate the current reference. Figures 7 and 8 show the test results of a 1100W bridgeless PFC. In this test, VIN=220V, VOUT=360V, and load=108W (about 10% of full load). Channel 1 is IIN, Channel 2 is VIN, and Channel 4 is the measured VIN signal with delay. In Figure 7, the measured VIN has no delay added, PF=0.86, THD=8.8%. In Figure 8, the measured VIN signal is delayed by 300us, in which case the PF is improved to 0.90. In addition, the PF can be further improved, but this will sacrifice THD because further delaying the current reference will produce more current distortion at the AC voltage crossover point. In Figure 9, the measured VIN is delayed by 500us, and the PF is improved to 0.92. However, the current is distorted at the voltage crossover point. As a result, THD became even worse, reaching 11.3%.

Figure 9 The measured VIN is delayed by 500us

Nonlinear Control

Compared with the current loop, the voltage loop control is less complex. In digital implementation, the output voltage VO is detected by an ADC and then compared with a voltage reference. We can use a simple proportional-integral (PI) controller to close the loop.

Where U is the control output, Kp and Ki are the proportional and integral gains respectively. E[n] is the DC output voltage error sampling value.

As mentioned earlier, one of the benefits of using digital control is that it enables nonlinear control. To improve transient response, nonlinear PI control can be used. Figure 10 is an example of nonlinear PI control. When the error is larger (usually in transients), the Kp gain used is larger. This will speed up the loop response when the error exceeds the set limit, and the recovery time is also shortened. For the integrator, it is another case. As we all know, the integrator is used to eliminate steady-state errors. However, it often causes saturation problems, and its 90° phase lag will also affect the stability of the system. For this reason, a nonlinear integral gain is used (Figure 10). When the error exceeds a certain level, the integral gain Ki is reduced to prevent saturation, overshoot, and instability.

Figure 10 Nonlinear PI control

Another advantage of digital voltage loop control is known as anti-integrator windup, which typically occurs when the AC drops. When the AC drops and the downstream load continues to draw current, the DC output voltage begins to drop while the PFC control loop still attempts to regulate its output. As a result, the integrator integrates and may saturate, a condition known as integrator windup. Once the AC returns, the saturated integrator may cause the DC output voltage to overshoot. To prevent this, the firmware resets the integrator as soon as AC is detected to be restored, and the DC output reaches its regulation point.

Digital controllers can also do more work, such as frequency jitter, system monitoring and communication, and can also provide flexible control, higher integration and higher performance for bridgeless PFC. In some high-end AC/DC designs, more and more designs are using digital controllers.

Reference address:Analysis based on improving the performance of bridgeless PFC high-performance power supply design

Previous article:Research on High Voltage Static VAR Compensator
Next article:ADIADP1053 three-way digital power supply control solution

Recommended ReadingLatest update time:2024-11-16 18:03

STM8S——Analog/digital converter (ADC)
1. ADC1 and ADC2 are 10-bit successive approximation Anolog to Digital Converters. The so-called successive approximation means successive approximation; 2. ADC is divided into ADC1 and ADC2. The function of ADC1 is more powerful than ADC2. We use ADC1. 3. ADC has multiple modes: (1) Single mode (2) Continuous
[Microcontroller]
Interesting talk about STM32 ADC and DMA
Recently, I was working on ADC sampling battery voltage, and sometimes I was a little confused. I can collect the voltage well without DMA, so why should I spend all that effort to use DMA? What if I make a mistake with DMA? The effect of not using DMA has not affected me to the point where I have to use it. Sometimes
[Microcontroller]
Interesting talk about STM32 ADC and DMA
37. Basic principles of STM32ADC
1. What is ADC   2. Characteristics of STM32ADC The number of ADC bits determines the accuracy of ADC, which can be 8-bit, 12-bit, 16-bit, etc. Another very important parameter is the conversion time. STM32f103RBT6 has 2 ADC controllers. 128KFlash, 20KRAM Each ADC controller has multiple channels. For example, A
[Microcontroller]
37. Basic principles of STM32ADC
Designing a power supply that meets European railway standards using DC/DC converter modules
The performance of electrical and electronic equipment for railway applications in Europe is governed by two international standards. In the design specifications, the most commonly used standard is IEC571 - Electronic equipment for railway vehicles, also known as European EN50155 - Electronic equipment for transport e
[Power Management]
Designing a power supply that meets European railway standards using DC/DC converter modules
Apple launches Mac version of developer app to get a more comprehensive understanding of WWDC
      On the morning of June 16, Apple #WWDC20# will be held online at 1 a.m. on June 23. On the eve of the conference, Apple launched the "Apple Developer" app on the Mac version of the App Store for the first time, allowing developers to better understand WWDC.   In the "Apple Developer" developer app, you can not
[Mobile phone portable]
Research on DC/DC Full-bridge Soft-Switching Converter for Photovoltaic Grid-connected System
  At present, most grid-connected inverters on the market use industrial frequency isolation type grid-connected inverters. Due to the disadvantages of industrial frequency transformers that make the system efficiency low, the size large, and the cost high, high-frequency isolation type grid-connected inverters have g
[Power Management]
Research on DC/DC Full-bridge Soft-Switching Converter for Photovoltaic Grid-connected System
Reading of surge overvoltage protection circuit diagram for DCU power port of automobile domain controller
In order to solve these problems of distributed EEA, automotive engineers have gradually begun to integrate many ECU functions with similar and separate functions into a processor hardware platform with stronger performance than ECU, which is the automotive "Domain Controller Unit (DCU)". The vehicle-mounted d
[Embedded]
Reading of surge overvoltage protection circuit diagram for DCU power port of automobile domain controller
Multiphase DC/DC converters provide high efficiency over the entire load range
Overview As demand for Internet services has grown significantly in recent years, electricity consumption in data centers around the world has become a significant issue. Data centers host web pages, enable social networking and streaming services, provide music and video downloads, provide Internet access,
[Power Management]
Multiphase DC/DC converters provide high efficiency over the entire load range
Latest Power Management Articles
Change More Related Popular Components
Guess you like

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号