一、载入不上或通讯不上的原因是什麽?


The reasons for communication failure and loading failure are roughly the same, which may be caused by the following reasons. Please compare the listed items with the operation:


1. Make sure the control system hardware is powered on correctly. (+5V)


2. Check and confirm that the serial cable used to connect to the controller is a straight-through cable, not a crossover cable.


3. Check and confirm that the serial port cable is intact and that both ends are not loose or falling off.


4. Refer to the LED screen control software and the control card you choose to select the correct product model, the correct transmission method, the correct serial port number, the correct serial transmission rate, and refer to the DIP switch diagram provided in the software to correctly set the address bits and serial transmission rate on the control system hardware.


5. Check whether the jumper cap is loose or fallen off; if the jumper cap is not loose, make sure the direction of the jumper cap is correct.


6. If the program still cannot be loaded after the above checks and corrections, please use a multimeter to measure whether the serial port of the connected computer or control system hardware is damaged to confirm whether the computer should be returned to the manufacturer or the control system hardware should be returned for inspection.


2. Why do bright lines appear for a few seconds or the screen becomes blurred when the LED screen is just powered on?


After properly connecting the screen controller to the computer, HUB distribution board and screen, you need to provide the controller with +5V power to make it work properly (do not connect it directly to 220V voltage at this time). At the moment of power-on, bright lines or "flower screen" will appear on the screen for a few seconds. These bright lines or "flower screen" are normal test phenomena, reminding users that the screen will start to work normally. Within 2 seconds, the phenomenon will automatically disappear and the screen will enter normal working state.


三、自动或手动亮度调节是什麽意思?


Brightness adjustment refers to the adjustment between the darkest and brightest that the screen can display, not the photosensitivity adjustment. Automatic brightness adjustment is the automatic adjustment of the LED screen control system to a predetermined brightness according to the different brightness that should appear in different time periods. Manual brightness adjustment means that the end user operates the LED screen control system to make the LED screen reach a specified brightness.


4. Reasons why the entire screen of the unit board is not bright or dim


1. Visually check whether the power connection cable, the 26P cable between the unit boards and the power module indicator light are normal.


2. Use a multimeter to measure whether the unit board has normal voltage, and then measure whether the voltage output of the power module is normal. If not, it is judged that the power module is broken.


3. Measure the voltage of the power module and find it is low. Adjust the fine-tuning (fine-tuning near the indicator light of the power module) to make the voltage reach the standard.


五、LED屏幕出现屏幕全黑的原因是什麽?


In the process of using the control system, we occasionally encounter the phenomenon that the LED screen appears completely black. The same phenomenon may be caused by various reasons, and even the process of the screen turning black may vary depending on different operations or different environments. For example, it may be black at the moment of power-on, or it may turn black during the loading process, or it may turn black after sending, etc.:


1. Please make sure that all hardware including the control system has been properly powered on. (+5V, do not connect it in reverse or incorrectly)


2. Check and re-confirm whether the serial port cable used to connect the controller is loose or detached. (If it turns black during the loading process, it is probably caused by this reason, that is, the communication line is loose and interrupted during the communication process, so the screen turns black. Do not think that the screen body does not move and the cable cannot be loose. Please check it yourself. This is very important if you want to solve the problem quickly.)


3. Check and confirm whether the HUB distribution board connected to the LED screen and the main control card is tightly connected and whether it is inserted reversely.

Keywords:LED Reference address:Five questions about LED screen failure repair

Previous article:How to Optimize LED Lighting Designs Using Buck or Boost Converters
Next article:Several factors to ensure the quality of LED large screen

Recommended ReadingLatest update time:2024-11-17 00:30

STM32_GPIO light up LED experiment
/*  Name: STM32_GPIO light up LED  Note: For STM32, the operation of LED is basically to operate the corresponding IO port.  Unlike 51, STM32 is equipped with a clock tree to take into account various devices, so when using the corresponding  When you start the device, you need to configure the clock tree (configured
[Microcontroller]
A novel LED dynamic display method
LED is often used as a display in single-chip microcomputer application systems. When multiple LED displays are required, in order to simplify the circuit and reduce costs, the selection lines of all gates are often connected in parallel and controlled by an 8-bit I/O port, while the common cathode (positive) I/O li
[Power Management]
A novel LED dynamic display method
A bare metal program about mini2440 - LED and button interrupt
span style="font-size:18px;" deep="5" /*       *File: main.c    *Description: When you press the key,    * the LED will show the key_value of key by the binary     * and produce the buzzer.    *Author: Cong    *Copyright : Cong    *    *    *History    *---------------------    *Rev :0.0    *Date: 2011/11
[Microcontroller]
Intelligent LED lighting control with heat dissipation monitoring
Thermal management is the most difficult, demanding, and expensive design aspect of new LED lamps . Failure to adequately manage thermal management can result in catastrophic consequences such as lighting failure or fire. However, thermal management of LED lamps is the most complex, demanding, and expensive
[Power Management]
Intelligent LED lighting control with heat dissipation monitoring
Nationstar Optoelectronics: The company's Micro LED chips have achieved small-batch supply
Recently, Nationstar Optoelectronics stated in an investor survey that the company focuses on the Mini/Micro LED ultra-high-definition display field and continues to launch core competitive product series: In terms of Mini LED, the company's research and development covers the full range of Mini direct display product
[Mobile phone portable]
Single chip microcomputer stepper motor speed control program (speed LED display)
The microcontroller source program is as follows: //Digital tube high position------low position //Four buttons to control the stepper motor: forward, reverse, plus 1, minus 1 //When the power is on, the motor starts, and the digital tube displays the minimum speed gear 1. The plus and minus gears can be displayed th
[Microcontroller]
Single chip microcomputer stepper motor speed control program (speed LED display)
LED: An industrial era opened by component innovation
LED is entering the traditional lighting field at an accelerating pace. According to Japanese media reports, LED sales accounted for 42.3% of total lighting product sales in the fourth week of May 2011, which is the first time that LED sales have exceeded incandescent lamps. With the follow-up of emerging markets, t
[Power Management]
Application of solar LED lamps in urban lighting
Preface Urban lighting is a science, a culture, and an art. Urban lighting reflects the image of a city, reflects the scientific management of a city, and is a social system project . Solar LED lamps are favored by customers for their superior energy-saving effects and humanistic light source lighting control.
[Power Management]
Latest Power Management Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号