Packaging glue type:
1. Epoxy Resin
2. Silicone
3、胶饼 Molding Compound
4. Silicone Hybrid
According to the molecular structure, epoxy resins can be roughly divided into five categories:
1. Glycidyl ether epoxy resin
2. Glycidyl ester epoxy resin
3. Glycidylamine epoxy resin
4. Linear aliphatic epoxy resin
5. Cycloaliphatic epoxy resin
Introduction to epoxy resin characteristics:
A glue:
Epoxy resin refers to an organic polymer compound containing two or more epoxy groups in the molecule, generally bisphenol A type epoxy resin
B glue:
Common organic compounds are anhydride compounds, such as: MHHPA
EPOXY:
Ether Bond is a weaker bond in epoxy encapsulation resin, which is prone to yellowing and light decay. A high proportion of A agent leads to more Ether Bond, which is prone to yellowing. Silicon resin replaces it with Si-O bond.
LED requirements for epoxy resin:
1. High reliability
2. High light transmittance.
3. Low viscosity, easy to degas.
4. The heat of hardening reaction is small.
5. Low thermal expansion coefficient and low stress.
6. High thermal stability.
7. Low hygroscopicity.
8. Excellent adhesion to metal, glass, ceramic, plastic and other materials.
9. Resistance to mechanical impact.
10. Low elasticity.
1. Glue cracking caused by poor hardening
Phenomenon: Cracking occurs in the colloid.
Cause: The hardening speed is too fast or the baking temperature is uneven, resulting in excessive internal stress accumulation in the colloid itself or between it and the metal material.
Treatment method:
1. Determine Tg to see if there is any poor hardening phenomenon.
2. Confirm the actual temperature inside the oven.
3. Check whether the temperature inside the oven is uniform.
4. Lower the initial baking temperature and extend the initial baking time.
2. Abnormality caused by poor stirring
Phenomenon: The colloid on the same surface is partially colored or the measured Tg and gelation time are different.
Cause: During stirring, the wall surface and bottom dead corners of the stirring container were not stirred evenly.
Treatment method:
1. Stir again.
2、升高A胶预热温度,藉以降低混合粘度。
3. Vacuum degassing bubble residue
Phenomenon: Bubbles continue to be generated during vacuum degassing.
reason:
1. The resin and hardener are preheated too high, resulting in continuous volatilization of the hardener during the bubbling process.
2. The bubbles that enter the injection molded object after viscosity increase are difficult to degas.
Treatment method:
1. Reduce the resin preheating temperature to 50~80℃, and maintain the bubble temperature at 50℃.
2. The hardener is not preheated.
4. Abnormal occurrence of colorants
Phenomenon: After using the same batch or the same can of colorant, there will be color difference and some cracks in the colloid.
reason:
1. Crystallization occurs in the colorant.
2. Uneven concentration leads to crystallization and sedimentation.
Treatment method:
According to the supplier's recommendations, different colors were given different pre-treatment temperatures and stirred evenly.
5. Abnormalities caused by moisture absorption of hardener
Phenomenon:
1. There are floating or sinking insoluble substances.
2. Opaque to milky white.
reason:
1. The hardener will turn into white crystals after hydrolysis.
2. Leave it for a long time after use.
3. The bottle cap is not locked tightly.
Treatment method:
1. Check whether there is any hydrolysis before use.
2. Anti-moisture measures.
Specific reaction process:
The normal colloid reaction process when B glue does not absorb moisture:
B glue hardener hygroscopic hydrolysis process:
After absorbing moisture, the hardener of glue B reacts with glue A. The reaction performance is poor, which reduces the mechanical and optical properties of the material:
6. Discoloration during long-bake hardening
Phenomenon: After being removed from the mold by short baking, there will be discoloration during long baking and hardening.
reason:
1. The temperature distribution in the oven is uneven.
2. The hardening materials are placed too close together in the oven. In addition to the reaction heat generated by the colloid, uneven heat convection may also cause it.
Treatment method:
Confirm the distribution location and quantity of hardened materials in the oven and the effect of oven heat circulation.
7. Poor quality of release from the mold after initial baking
Phenomenon: Difficult to release from the mold.
reason:
1. Moulding quality.
2. The initial baking hardening is incomplete and the hardening rate is too fast.
3. The mold machine is offset.
Treatment method:
1. Confirm the curing temperature and check the gelling time.
2. Make sure the demoulding machine maintains vertical demoulding.
Phenomenon: After leaving the mold, the surface of the colloid becomes atomized.
reason:
1. Excessive use of release agent.
2. The mold strip is used too many times.
3. Before spraying the demoulding agent, the temperature of the mold strip is too low.
Treatment method:
1. Adjust the amount of release agent used.
2. Pay attention to the number of times the mold strip is used.
8. Hardener discoloration
Phenomenon: The hardener turns yellow-brown.
reason:
1. Caused by thermal oxidation.
2. Caused by oxidation by UV-VIS light.
3. The hardener is left for a long time or in a high temperature place.
Treatment method:
1. The hardener cannot be preheated.
2. Keep in a dark place.
9. Solidification of diffusant
Phenomenon: No fluidity, solid shape.
Reason: After adding inorganic substances, the resin becomes solid.
Treatment method: Heat to melt.
10. Bracket Climbing
Phenomenon: The bracket cannot be tinned when it is glued or passed through the tin furnace.
Cause: The surface of the bracket is uneven, causing capillary phenomena, or it contains release agent.
Treatment method:
1. Confirm the quality of the bracket.
2. Use glue or thinner with low VOC content.
3. Use external spray glue.
11. There are bubbles on the rack after the initial baking
Phenomenon: Bubbles occur continuously around the support in the hardened material.
Cause: The bracket is stored in a place with high humidity, and the operating environment humidity is high.
Treatment method: Pay attention to the humidity of the operating environment.
Previous article:New high-efficiency high-power LED lighting device micro-heat pipe cooling solution
Next article:In-depth analysis of LED street light testing technology, standards and development prospects
- MathWorks and NXP Collaborate to Launch Model-Based Design Toolbox for Battery Management Systems
- STMicroelectronics' advanced galvanically isolated gate driver STGAP3S provides flexible protection for IGBTs and SiC MOSFETs
- New diaphragm-free solid-state lithium battery technology is launched: the distance between the positive and negative electrodes is less than 0.000001 meters
- [“Source” Observe the Autumn Series] Application and testing of the next generation of semiconductor gallium oxide device photodetectors
- 采用自主设计封装,绝缘电阻显著提高!ROHM开发出更高电压xEV系统的SiC肖特基势垒二极管
- Will GaN replace SiC? PI's disruptive 1700V InnoMux2 is here to demonstrate
- From Isolation to the Third and a Half Generation: Understanding Naxinwei's Gate Driver IC in One Article
- The appeal of 48 V technology: importance, benefits and key factors in system-level applications
- Important breakthrough in recycling of used lithium-ion batteries
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
- What are the key points of GaN? Do you know them all?
- 【Application development based on NUCLEO-F746ZG motor】5. Motor operation
- Webench Power Supply Design Training Video Series
- C Language Zone (3) Continuous Printing
- [Synopsys IP Resources] What is multi-die design - and why is it gaining popularity?
- The difference between Sendust magnetic ring in inductance and ferrite inductance
- imx8-cb300 core board
- Embedded Development Engineer
- A question about the power cord
- How to select the conversion method in J1939 fault code DTC?