How to prevent oscilloscope current probe damage?

Publisher:温馨家园Latest update time:2021-12-02 Source: eefocusKeywords:Oscilloscope Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

The oscilloscope probe is crucial to the accuracy and correctness of the measurement results. It is an electronic component that connects the circuit under test to the input terminal of the oscilloscope and is an indispensable accessory for the oscilloscope. The oscilloscope current probe is a magnetic ring designed based on the Faraday principle to measure the interference current signal in the wire. It is essentially a transformer with 1 turn. The current probe can be used to measure the current flowing through the wire.

Although the oscilloscope current probe is just a small accessory, it is indeed indispensable for electronic engineers. Moreover, the probe is a consumable item and is easily damaged. Antai Testing has found that the parts of the probe that are easily damaged are roughly as follows through the fault analysis of damaged oscilloscope current probes:

1. Circuit board connected to the current amplifier;

2. The magnetic ring of the current probe is broken;

3. Magnetic ring coil of current probe;

4. The appearance of the sliding clip of the current probe is damaged;

5. The cable is broken.


Causes of damage to oscilloscope current probes, methods to prevent damage and instructions for use The causes of damage to the above five parts can be summarized as follows:

1. After the current amplifier is powered on, the circuit board is damaged by plugging and unplugging the current probe.

Remember not to plug or unplug the current probe while it is powered on.

2. The magnetic ring is a fragile material. It is easy to break if it is dropped or used with excessive force. A damaged magnetic ring will cause inaccurate testing or no current can be measured.

Avoid dropping or applying excessive force when using

3. The magnetic ring coil is relatively thin, and overcurrent will cause the coil to burn out.

Avoid overcurrent when using

4. If the current clamp is not aligned or has cracks, the test will be inaccurate or the current cannot be measured. Note that you should be careful when pushing the clamp.

The current clamp should be aligned when in use. Pay attention and be careful when pushing the clamp.

5. The cable will be easily damaged if it is pulled or twisted too hard.

Do not pull or twist the cable too hard when using it.


The operation method provided above is relatively simple and can be done with a little attention. However, operators are often prone to neglect it in their tense and busy work. We hope that users will pay attention to reduce unnecessary damage to the oscilloscope current probe.


The probe is a precision accessory instrument and an indispensable accessory of the oscilloscope. Without the probe, the oscilloscope cannot work. Antai Testing specializes in repairing various oscilloscope probe models:

Current probe series:

A621 A622 CT2 CT1 TRCP0300 TCP305A P6021A TRCP3000 P6022 TCP312A TCPA400 TCP2020 TCPA300 TCP0020 TCP303 TCP0030A TCP404XL TCP0150;

High voltage split probe series:

P5200A P5202A P5205A THDP0200 TMDP0200 P5210A THDP0100 TDP0500 TDP1000 P6251;

Passive probe series:

P2220 P2221 P6101B P3010 TPP0250 P36139B P5050B;

High Voltage Single-Ended Probes:

P5122 P5100A P5150 TPP0850 P6015A;

Low voltage single-ended probe:

P6243 P6245 TAP1500 TAP2500 TAP3500 P7240;

Oscilloscope probe repairable faults:

It does not work properly, and the customer confirms that the host is normal.


Keywords:Oscilloscope Reference address:How to prevent oscilloscope current probe damage?

Previous article:Brief introduction to the functional classification and application fields of handheld oscilloscopes
Next article:How to choose a suitable probe for your oscilloscope

Latest Test Measurement Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号