What are the applicable modes of external triggering of the function generator? How to set the triggering mode?

Publisher:码农闲散人Latest update time:2021-07-30 Source: eefocus Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

The external trigger of the function generator only supports two output modes: sweep and burst. The trigger source is divided into internal and external.


Triggering can only be selected in sweep and burst modes.


Let's take Keysight's 33220A as an example. If you set Trigger source to EXTERNAL, the 33220A will receive input signals from an external trigger source. If you set TRIGGER SOURCE to INTERNAL or MANUAL, the 33220A can also output trigger signals to external instruments. The types of these trigger signals are optional and are divided into rising edge and falling edge.


Related question: What is the minimum delay time that can be set for external triggering of 33500 and 33600 series function generators?


The minimum time for the 33500 series is 135ns; the minimum time for the 33600 series is 140ns.


From the data indicators, we can see that when the trigger delay is set to 0, the delay between receiving the trigger input and the waveform synthesizer inside the 33600A starting to generate output is less than 135 or 140ns. Regardless of the trigger delay setting value, the trigger delay needs to be increased.


That is, actual delay = delay setting + trigger delay (<140ns)


Reference address:What are the applicable modes of external triggering of the function generator? How to set the triggering mode?

Previous article:How to perform passive probe bandwidth compensation
Next article:Oscilloscope trigger mode selection

Latest Test Measurement Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号