The oscilloscope displays the signal on the screen, and the results displayed on the screen can be used to study the device under test. Most people usually encounter some problems when using an oscilloscope, such as the screen is not lit, there is no signal display, etc. For some common problems, we can determine the cause of the fault through simple detection:
1. After pressing the switch and turning on the power, the oscilloscope screen is not lit, and there is no display. When we encounter this kind of fault, don't worry, you can perform self-tests through the following points:
1) First check whether the power connector is connected properly. If it is not plugged in or loose, and there is no power, the screen will definitely not display.
2) Check whether the power switch is pressed
3) If you have completed the above checks, you can restart the oscilloscope.
4) The product will not display if it is not triggered to scan.
If the above tests still do not display normally, you can restart. If it still does not display normally, there may be a problem inside the oscilloscope. You should consult the corresponding supplier or send it for repair.
2. During use, signal acquisition is performed, but no wave appears. In this case, we can find the cause through 4-point detection:
1) Is the product probe connected to the signal connection line?
2) Is the signal connection line normally connected to the BNC?
3) Is the probe normally connected to the measured object
? 4) Is the object being detected generating a signal?
5) If there are no problems with the above, we can collect again. If it still does not display, you can consult the personnel.
3. The measured voltage amplitude value is 10 times larger than the actual value or 1/10 of the actual value.
Check whether the attenuation coefficient of the channel is consistent with the attenuation ratio of the probe actually used.
4. There is a waveform display, but it cannot be stabilized
1) Check whether the signal source option on the trigger panel matches the actual signal channel used.
2) Check the trigger type. Only when the appropriate trigger mode is applied can the waveform be displayed stably.
3) Try changing the "coupling" to "high frequency suppression" or low frequency suppression display to filter out the high frequency or low frequency noise that interferes with the trigger.
5. Press the RUN/STOP button but nothing is displayed. The troubleshooting method is as follows: Check whether the trigger mode of the trigger panel is normal or word mode, and the trigger level exceeds the waveform range. If it is, center the trigger level. Or set the trigger mode to automatic mode. In addition, press the AUTO button to automatically complete the above settings.
Previous article:Common faults and repair methods of ultrasonic generators
Next article:Where do the brilliant colors come from? LOTO oscilloscope measures WS2812B LED light source
- New IsoVu™ Isolated Current Probes: Bringing a New Dimension to Current Measurements
- Modern manufacturing strategies drive continuous improvement in ICT online testing
- Methods for Correlation of Contact and Non-Contact Measurements
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- Intel promotes AI with multi-dimensional efforts in technology, application, and ecology
- ChinaJoy Qualcomm Snapdragon Theme Pavilion takes you to experience the new changes in digital entertainment in the 5G era
- Infineon's latest generation IGBT technology platform enables precise control of speed and position
- Two test methods for LED lighting life
- Don't Let Lightning Induced Surges Scare You
- Application of brushless motor controller ML4425/4426
- Easy identification of LED power supply quality
- World's first integrated photovoltaic solar system completed in Israel
- Sliding window mean filter for avr microcontroller AD conversion
- What does call mean in the detailed explanation of ABB robot programming instructions?
- STMicroelectronics discloses its 2027-2028 financial model and path to achieve its 2030 goals
- 2024 China Automotive Charging and Battery Swapping Ecosystem Conference held in Taiyuan
- State-owned enterprises team up to invest in solid-state battery giant
- The evolution of electronic and electrical architecture is accelerating
- The first! National Automotive Chip Quality Inspection Center established
- BYD releases self-developed automotive chip using 4nm process, with a running score of up to 1.15 million
- GEODNET launches GEO-PULSE, a car GPS navigation device
- Should Chinese car companies develop their own high-computing chips?
- Infineon and Siemens combine embedded automotive software platform with microcontrollers to provide the necessary functions for next-generation SDVs
- Continental launches invisible biometric sensor display to monitor passengers' vital signs
- Application Notes on Flash Serial Programming for HuaDa MCU F003/F005/L110 Series
- A DSP Processor Design Based on Power Consumption Management
- MSP430 timer output PWM
- MSP430 register detailed classification
- EEWORLD University Hall----Open Source PWM Robotic Arm (Arduion Version)
- Design of Data Acquisition System Based on ARM7+μCOSII
- Next week, we will start learning about ESP32
- 1MHz square wave double frequency
- CC3200 Modify the sprinkler routine of Out of Box
- Upgrading the embedded RISC-V compiler