LCR tester usage diagram_LCR tester usage guide

Publisher:千变万化Latest update time:2020-02-17 Source: elecfans Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

  How to use LCR tester

  1. Prepare the LCR tester. The white button is the switch.

How to use LCR tester


  2. The commonly used buttons are ZLCR to change the main measurement function, and DQe to change the auxiliary measurement function.

How to use LCR tester

  3. Prepare the peripheral connector

How to use LCR tester

  4. Connect the computer and LCR as shown in the figure

How to use LCR tester

  5. The tester screen will display the measurement data.

How to use LCR tester

  6. Start measuring


  How to correct the error of LCR tester

  To reduce measurement errors, LCR meters have several correction functions. The correction values ​​vary depending on the frequency and impedance range, so it takes a lot of time to perform full range correction.


  Here, zero point calibration and load calibration are explained.


  Zero calibration: When the zero drift of the LCR meter is not negligible for the measured value, a zero calibration is required. Because the zero drift varies with the physical configuration of the cables and electrodes, the cable routing and electrode spacing must be the same when connecting the components when performing open and closed circuit zero calibration.


  Load correction: In addition to the zero drift caused by different measuring fixtures, if there are measurement errors that cannot be ignored, load correction can be performed to improve measurement accuracy. Even for LCR testers without load correction function, correction coefficients can be obtained for each impedance range and frequency, and correction can be performed by itself.


  In order to perform load calibration, you first need to prepare standard instruments or parts with known accurate values. After performing zero point calibration, measure the standard impedance Zstd with known accurate value. If the measured value is Zms, then calculate the correction factor according to the following formula.

Reference address:LCR tester usage diagram_LCR tester usage guide

Previous article:Understand the testing principle and main functions of LCR tester in one article
Next article:Application of FLIR thermal imaging camera in the exploration of spontaneous combustion of coal

Latest Test Measurement Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号