When using a pointer multimeter to detect DC voltage values, you can use the DC voltage block to detect the DC voltage value. Next, Engineer Chen from Instrument Work Online will introduce how to read the readings when using a pointer multimeter to detect DC voltage.

(1) If the DC voltage 2.5V gear is selected, if the pointer points to the 1.75V gear position, when reading the voltage value, select the 0~250 dial to read the value. Due to the multiple relationship between the gear position and the dial, the measured voltage value is: 175X(2.5/250)=1.75V.

(2) Select the DC voltage 50V position. If the pointer points to the 35V position, when reading the voltage value, select the 0~250 dial to read the value. The measured voltage value is 35V.

(3) Select the DC voltage 25V position. If the pointer points to the 17.5V position, when reading the voltage value, select the 0~250 dial to read the value. Due to the multiple relationship between the position and the dial, the measured voltage value is: 175X(25/250)=17.5V

(4) Select the DC voltage 250V position. If the pointer points to the 175V position, when reading the voltage value, select the 0~250 dial to read the value. The measured voltage value is 175V.

(5) Select the DC voltage 1000V position. If the pointer points to the 700V position, when reading the voltage value, select the 0~10 dial to read the value. Due to the multiple relationship between the position and the dial, the measured voltage value is: 7X(1000/10)=700V. When reading the value, as long as you find the multiple relationship between them, you can read the value accurately.

Reference address:How to read the DC voltage range of a pointer multimeter

Previous article:Precautions before using the megohmmeter
Next article:How to Use a Digital Multimeter?

Latest Test Measurement Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号