There are no moving parts in the sensor, the structure is simple and the operation is reliable.
The plug-in structure can be easily installed and disassembled without stopping water under low pressure or pressure. Therefore, it is very suitable for fluid measurement in existing pipelines and is convenient for maintenance and repair of instruments.
The measurement accuracy is not affected by changes in physical parameters such as temperature, pressure, density, viscosity, conductivity (as long as the conductivity is greater than 5µs/cm) of the measured medium.
The sensor has almost no pressure loss and extremely low energy loss.
The manufacturing cost and installation cost are lower than those of general electromagnetic flowmeters. It is particularly suitable for flow measurement in large and medium diameter pipelines.
It adopts advanced low-frequency square wave excitation. It has stable zero point, strong anti-interference ability and reliable operation.
The flow measurement range is large. The full-scale flow velocity in the measured pipeline can be set arbitrarily from 1m/s to 10m/s, and the output signal is linearly related to the flow rate.
The flowmeter not only has 0~10mA DC or 4~20mA DC standard current output, but also 1~5kHz frequency output
Reference address:Insertion type electromagnetic flowmeter sensor has the following features
The plug-in structure can be easily installed and disassembled without stopping water under low pressure or pressure. Therefore, it is very suitable for fluid measurement in existing pipelines and is convenient for maintenance and repair of instruments.
The measurement accuracy is not affected by changes in physical parameters such as temperature, pressure, density, viscosity, conductivity (as long as the conductivity is greater than 5µs/cm) of the measured medium.
The sensor has almost no pressure loss and extremely low energy loss.
The manufacturing cost and installation cost are lower than those of general electromagnetic flowmeters. It is particularly suitable for flow measurement in large and medium diameter pipelines.
It adopts advanced low-frequency square wave excitation. It has stable zero point, strong anti-interference ability and reliable operation.
The flow measurement range is large. The full-scale flow velocity in the measured pipeline can be set arbitrarily from 1m/s to 10m/s, and the output signal is linearly related to the flow rate.
The flowmeter not only has 0~10mA DC or 4~20mA DC standard current output, but also 1~5kHz frequency output
Previous article:Working principle of Roots flowmeter
Next article:Roots flowmeter product features and application range
- Popular Resources
- Popular amplifiers
Recommended Content
Latest Test Measurement Articles
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
MoreSelected Circuit Diagrams
MorePopular Articles
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
MoreDaily News
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
Guess you like
- TechTest Elite Development Program - Answer questions and win gifts!
- Big summary! All sensor types are here
- A Bluetooth brake pedal monitor designed for Tesla owners
- NXP Rapid IoT Review】+④NXP Rapid IoT Operation Time Synchronization
- [Evaluation of EVAL-M3-TS6-665PN development board] 1. Hardware circuit
- What issues should be paid attention to when designing MCU for low power consumption
- AM335X GPIO Register Operation
- Overview of IoT Communication Technologies
- ESD Request Assistance
- How to compensate for the unbalanced output of a strain gauge bridge?