Mechanical mud density meters need to be tested for discrimination, which is also called sensitivity limit. It mainly checks the integrity of the knife edge and knife bearing of the mechanical mud density meter. Because the pressure on the knife edge and knife bearing is the largest at full scale, the instrument's discrimination value is the largest, so the discrimination should be tested at full scale. The smaller the discrimination value is, the worse the durability of the instrument is, and it cannot meet the harsh environmental conditions of the construction site. Since electronic mud density meters do not have knife edges and knife bearings. Therefore, electronic mud density meters do not perform discrimination tests.
The zero point adjustment of the mechanical mud density meter is very important for the mud density meter. The accuracy of the zero point will affect the indication errors of other points. Since the density of the zero point is traced back to pure water, it is necessary to use clean pure water; the sample cup should be prevented from tilting during operation, as bubbles are easily retained in the tilted sample cup, which will cause the zero point to produce error errors; when adjusting the counterweight of the adjustment chamber, the zero point adjustment should be performed with the adjustment chamber cover covered; the zero point adjustment of the pressurized mud density meter should be paid more attention to, and it must be performed when the sample cup is pressurized, otherwise, if the pressurization valve is not closed, there will be a large error in the zero point adjustment.
If the zero point adjustment of the mud density meter is accurate, but the indication error of the instrument increases or decreases linearly with the increase of the measurement point, then the mass of the mud density meter's sliding weight changes due to wear and other reasons and does not match the scale. It can be adjusted by adjusting the mass of the sliding weight, and this work should be performed by the manufacturer.
The adsorption of water by the inner wall of the sample cup will cause the mud density meter to produce systematic errors, especially for the pressurized mud density meter, the inner wall of the metal sample cup and the cup cover of the pressurized air hole will absorb a lot of water, increasing the measurement error. For this reason, the procedure adds a method for handling liquid residues to improve the accuracy of the measurement.
Whether the position of the substitute is evenly placed has a great influence on the measurement results. Therefore, attention should be paid to the uniformity of the placement of the substitute to eliminate the influence of eccentric load on the indication of the mud density meter.
Reference address:How to measure the mud density meter
The zero point adjustment of the mechanical mud density meter is very important for the mud density meter. The accuracy of the zero point will affect the indication errors of other points. Since the density of the zero point is traced back to pure water, it is necessary to use clean pure water; the sample cup should be prevented from tilting during operation, as bubbles are easily retained in the tilted sample cup, which will cause the zero point to produce error errors; when adjusting the counterweight of the adjustment chamber, the zero point adjustment should be performed with the adjustment chamber cover covered; the zero point adjustment of the pressurized mud density meter should be paid more attention to, and it must be performed when the sample cup is pressurized, otherwise, if the pressurization valve is not closed, there will be a large error in the zero point adjustment.
If the zero point adjustment of the mud density meter is accurate, but the indication error of the instrument increases or decreases linearly with the increase of the measurement point, then the mass of the mud density meter's sliding weight changes due to wear and other reasons and does not match the scale. It can be adjusted by adjusting the mass of the sliding weight, and this work should be performed by the manufacturer.
The adsorption of water by the inner wall of the sample cup will cause the mud density meter to produce systematic errors, especially for the pressurized mud density meter, the inner wall of the metal sample cup and the cup cover of the pressurized air hole will absorb a lot of water, increasing the measurement error. For this reason, the procedure adds a method for handling liquid residues to improve the accuracy of the measurement.
Whether the position of the substitute is evenly placed has a great influence on the measurement results. Therefore, attention should be paid to the uniformity of the placement of the substitute to eliminate the influence of eccentric load on the indication of the mud density meter.
Previous article:Make the online tester really work
Next article:Leak detection and classification of vacuum gauges
- Popular Resources
- Popular amplifiers
Latest Test Measurement Articles
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
MoreSelected Circuit Diagrams
MorePopular Articles
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
MoreDaily News
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
Guess you like
- What is the highest sampling rate that the McASP of TMS320C6748 can support?
- [McQueen Trial] The fourth post is delayed - Try the Arduino IDE development environment & timer interrupt
- [Zero-knowledge ESP8266 tutorial] Quick Start 8-Reading analog values
- Invitation | Visit the Avnet Artificial Intelligence Cloud Exhibition, read useful information online, and win gifts!
- In this circuit, why does the PMOS turn on as soon as it is powered on?
- !!! Help "Does anyone know how to solder SIM900A on the perf board?"
- Watch Shuige's video for a reward | How to save oscilloscope data and pictures to a remote PC
- LOTO virtual oscilloscope software function demonstration - FIR digital filtering
- How to compile the image for SINA33 development board
- CalcToolBox 2 based on micropython