pdf

Conducted EMC Testing Guide!

  • 2013-09-29
  • 108.43KB
  • Points it Requires : 2

              Conducted EMC test guidance GSM dual-band digital mobile phone EMC test guidance Reference standards and scope of application a. YD 1032-2000 900/1800MHz TDMA digital cellular mobile communication system Electromagnetic compatibility limits and measurement methods Method 1.2 Scope of application This regulation applies to the mid-term test and inspection of new products of mobile stations (MS) of 900/1800MHz TDMA digital cellular mobile communication network general packet radio service (GPRS). 2. Test conditions Temperature: 15℃-35℃ Relative humidity: 45%-75% Atmospheric pressure: 86-106kPa Ambient noise: no more than 60dB (A) 2.2 Electromagnetic environment conditions: A 90dB isolation shielded room and power filter should be used to ensure that the electromagnetic environment does not affect the test results 2.3 Test power supply: mobile phone lithium battery 3. Test instruments Spectrum analyzer, comprehensive tester, notch filter, RF attenuator 4. Measurement method and limit of stray interference DC 4.2V~3.3V 2.1 Climate conditions: Part 1: Mobile station and its auxiliary equipment b. YD/T 884-1996 900/1800MHz TDMA digital cellular mobile communication network mobile station equipment technical indicators and measurements 11.1 Reference standards 4.1 Conducted stray interference 4.1.1 Definition Conducted stray interference is a discrete interference signal on a 50Ω load. 4.1.2 Measurement method (dedicated mode) a. Instrument connection as shown in Figure 1 b. Use 6G signal source to calibrate the attenuation of each channel at the frequency to be tested. c. Initialize the mobile phone under test according to 4.8.1.1 (YD 1032); on the channel corresponding to the central ARFCN, SS establishes communication with EUT according to the general calling process. For example, for GSM 900MHZ, the value of ARFCN is between 60-65. At the same time, SS commands EUT to work with the maximum output power level. That is, PCL 5. d. Set the parameters of the receiver or spectrum analyzer. For bandwidth settings, please refer to Table 1 (national regulations). The center frequency is set at the frequency of the harmonic to be tested. Other settings (Span, Ref Level, Attenuation, ...             

unfold

You Might Like

Uploader
nkyqsl
 

Recommended ContentMore

Popular Components

Just Take a LookMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号
×