Transformer Principle PPT

  • 2013-09-22
  • 875.5KB
  • Points it Requires : 1

Classification and models of transformers 1. Classification by voltage rise and fall: there are two types: step-up transformers and step-down transformers. 2. Classification by number of phases: there are single-phase transformers, three-phase transformers and multi-phase transformers. 3. Classification by purpose: there are power transformers used in power supply and distribution systems; there are instrument transformers (voltage transformers and current transformers) used for measurement and relay protection; there are test transformers for withstand voltage tests of high-voltage power supply equipment; there are transformers for special purposes such as electric furnace transformers, welding transformers and rectifier transformers. 4. Classification by cooling method and cooling medium: there are dry-type transformers cooled by air; there are oil-immersed transformers cooled by oil; there are water-cooled transformers cooled by water. At present, the small and medium-sized transformers produced in my country mainly include S5, SL5, SF5, SZ5, SZL5 and other series. The meanings of these symbols are: S-three-phase; D-single-phase; F-air cooling; W-water cooling; Z-on-load voltage regulation; L-aluminum coil transformer. For example, a transformer model is 2. Transformer structure 3. Transformer rating The transformer rating is the technical limit to ensure that the transformer can operate reliably for a long time and has good working performance. It is also the basis for manufacturers to design, manufacture and test transformers. Its contents include the following aspects: 1. Rated voltage U1N/U2N U1N and U2N are the rated voltages of the primary and secondary sides respectively, which refers to the guaranteed value of the terminal voltage when the transformer is unloaded, expressed in effective value. For three-phase transformers, they all refer to line voltage, the unit is V or kV. 2. Rated current I1N/I2N I1N and I2N are the rated currents of the primary and secondary sides respectively, which refers to the maximum effective value of the current allowed to pass through the primary and secondary windings when the transformer is running continuously. The rated current of a three-phase transformer refers to the line current, the unit is A. 3. Rated capacity SNSN is the power output capacity of the transformer under rated conditions. The unit is V·A or kV·A. For a single-phase transformer SN=U1NI1N=U2NI2N (1) For a three-phase transformer SN= U1NI1N= U2NI2N (2) 4. Rated frequency fN refers to the power frequency that the transformer should be connected to. The standard frequency of my country\'s power system is 50Hz. [Example 1] The rated capacity of a lighting transformer is 500V·A, and the rated voltage is 220V/36V. Find: (1) The rated current of the primary and secondary sides; (2) How many 36V, 100W incandescent lamps can be connected to the secondary side at most? IV. Working principle 1. Magnetomotive force F F=N1i1 (3) Magnetic flux is generated by it, and its unit is ampere (A). 2. Magnetic flux  Magnetic flux refers to the total number of magnetic lines of force passing through a certain area perpendicular to the direction of the magnetic field. Its international unit is Wb. In the past, the electromagnetic unit MX was sometimes used in engineering. The conversion formula between them is 1Wb=108MX =F/Rm (4) Formula (4) is similar to Ohm\'s law in the circuit in form, where Rm is the magnetic resistance. Table 1 Comparison of magnetic circuit and circuit 3. Magnetic induction intensity BB=/S (5) If the magnetic induction intensity B at each point in the magnetic field is equal in magnitude and direction, such a magnetic field is called a uniform magnetic field. 4. Magnetic permeability  Magnetic permeability  is a physical quantity that characterizes the magnetic conductivity of a material. It indicates the degree of influence of the material on the magnetic field. 5. Magnetic field intensity H Magnetic field intensity H is also a physical quantity that characterizes the strength and direction of the magnetic field, but it does not include the magnetic field generated by the magnetization of the magnetic medium. Its international unit is A/m. Therefore, H=B/ (7)

unfold

You Might Like

Uploader
hellopinkgirls
 

Recommended ContentMore

Popular Components

Just Take a LookMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号
×