SXE15 Series
DC-DC CONVERTERS
Single output
10.8-15 W High Efficiency DC-DC Converters
1
•
High efficiency topology, 87% typical at 5 V
•
Wide operating temperature, up to and exceeding 70 ˚C
(natural convection)
•
90% to 110% output trim
•
No minimum load
•
Overvoltage protection
•
Remote ON/OFF control
•
Available RoHS compliant
The SXE15 is a new high efficiency open frame isolated 15 Watt converter series in
an industry standard footprint. All models in the series feature an input voltage range
of 33 Vdc to 75 Vdc and are available in output voltages of 12 V, 5 V, 3.3 V, 2.5 V
and 1.8 V. The output voltage on each model is adjustable from 90% to 110% of the
nominal value. Typical efficiencies for the models are 87% for the 5 V, 86% for the
3.3 V, 85% for the 2.5 V and 12 V and 83% for the 1.8 V version. The SXE15 series
also has a remote ON/OFF capability with active high or active low logic.
Overcurrent and overvoltage protection features are included as standard. With full
international safety approval including EN60950 and cUL1950, the SXE15 reduces
compliance costs and time to market.
TÜV
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
Total error band
Line regulation
Low line to high line
Load regulation
Full load to min. load
Minimum load
Overshoot
At turn-on and turn-off
Undershoot
Ripple and noise
(See Note 1)
5 Hz to 20 MHz
Transient response
(See Note 2)
Typical deviation
INPUT SPECIFICATIONS
Input voltage range
Input current
Input current (max.)
Input reflected ripple
48 Vin nominal
No load
Remote OFF
(See Note 4)
(See Note 6)
33-75 Vdc
35 mA max.
25 mA max.
0.55 A max. @ Io max.
and Vin = 33-75 Vdc
5 mA (pk-pk) typ.
(See Note 8)
Open collector ref to -input
Open circuit or >2 Vdc
<1.2 Vdc
33 V (typ.)
30 V (typ.)
1.5 ms (typ.)
2.5 ms (typ.)
1.8 V and 2.5 V models
3.3 V and 5 V models
(See Note 13)
1.8 V and 2.5 V models
3.3 V and 5 V models
1.8 V model
2.5 V model
3.3 V and 5 V models
(See Note 12)
1.8 V and 2.5 V models
3.3 V and 5 V models
90% to 110%
±4% max.
0.5% max.
0.1% max.
2.0% max.
1.5% max.
0.5% max.
0%
4% max.
None
None
40 mV pk-pk
14 mV rms
70 mV pk-p
20 mV rms
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (dc power)
Conducted (signal)
Input transients
EN55022 (See Note 3)
Level A
EN55022 (See Note 3)
Level B
EN55022 (See Longform Datasheet) Level B
EN61000-4-2 8 kV, 15 kV
EN61000-4-2 6 kV, 8 kV
EN61000-4-3 10 V/m
EN61000-4-6 10 V
EN61000-4-6 10 V
(See Note 11)
ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency
Operational insulation
Switching frequency
Approvals and
standards
Material flammability
Weight
Coplanarity
MTBF
Representative model:
Input/output
Fixed
(See Notes 5)
See table
1500 Vdc
265 kHz typ.
UL/cUL1950, EN60950
TÜV Rheinland
UL94V-0
12 g (0.42 oz)
150 µm
MIL-HDBK-217F
1,790,000 hours
48S05J @ 48 Vin, 40 °C,
100% load ground benign
BELLCORE 332
>1,500,000 hours
1.8 V and 2.5 V models
150 mV
3.3 V and 5 V models
100 mV
400 µs recovery to
within total error band
ENVIRONMENTAL
SPECIFICATIONS
Thermal performance
(See Note 9)
Operating ambient
temp. (3.3 V and 5 V)
Operating ambient
temp. (1.8 V, 2.5 V
and 12 V)
Non-operating
(All models)
-40 °C to +65 °C
-40 °C to +70 °C
Active high remote ON/OFF
Logic compatibility
ON
OFF
Undervoltage lockout
Start-up time
(See Note 7)
Power up
Power down
-40 °C to +120 °C
Power up
Remote ON/OFF
File Name: sxe15s.pdf Rev (02): 08 Dec 2005
SXE15 Series
DC-DC CONVERTERS
OUTPUT
POWER
(MAX.)
10.8 W
15 W
15 W
15 W
15 W
Notes
1
2
3
Single output
10.8-15 W High Efficiency DC-DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
33-75 Vdc
33-75 Vdc
33-75 Vdc
33-75 Vdc
33-75 Vdc
OVP
2.3 Vdc
3.2 Vdc
4 Vdc
6 Vdc
15 Vdc
(10)
OUTPUT
VOLTAGE
1.8 V
2.5 V
3.3 V
5V
12 V
OUTPUT
CURRENT
(MIN.)
0A
0A
0A
0A
0A
OUTPUT
CURRENT
(MAX.)
6A
6A
4.5 A
3A
1.25 A
EFFICIENCY
(TYP.)
83%
85%
86%
87%
85%
REGULATION
LINE
0.3%
0.3%
0.1%
0.1%
0.1%
LOAD
2.0%
1.5%
0.5%
0.5%
0.5%
MODEL
NUMBER
(8,14,15)
SXE15-48S1V8J
SXE15-48S2V5J
SXE15-48S3V3J
SXE15-48S05J
SXE15-48S12J
4
5
6
7
8
9
10
11
12
13
14
15
Measured as per recommended set-up. See Application Note 116 for details.
di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
The SXE15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for details.
Recommended input fusing is a 2 A HRC 200 V rated fuse.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Measured with external Pi filter. See Application Note 116 for further details.
Start-up into resistive load.
Active low remote on/off is available. Standard product is active high.
Designate with the Suffix ‘-R’ e.g. SXE15-48S05-RJ.
Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow.
See Application Note 116 for further details.
SXE15-48S12J below 0.2 A loading. OVP is TVS and 17 V typical.
Signal line assumed < 3 m in length.
A 5% minimum load is required to maintain the output voltage regulation
over all operating conditions for the SXE15-48S12J.
This parameter is calculated at worst case line, load,
temperature and initial settings.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
1.905 (48.39)
overall length
1.150 (29.21)
TOP VIEW
1.390 (35.31)
1.885 (47.88)
leadframe length
0.070 (1.78) MAX
SIDE VIEW
1.812 (46.03)
0.010 (0.25) MIN
0.335 (8.51) MAX
Tolerence:
±.015
(±.38)
Recommended Land & Hole Pattern
1.575 (40.01)
0.197 (5.00)
0.394 (10.01)
1.812 (46.02)
BOTTOM VIEW
0.047 (1.18)
ø.050 (ø1.27)
Non-Skid Retaining Pins,
2 Places
ø0.063 (ø1.60)
1.812 (46.02)
0.477 (12.11)
0.502 (12.75)
1
0.130 (3.30)
0.053 (1.36)
1.181 (30.00)
0.069 (1.74)
0.197 (5.00)
0.394 (10.01)
1.181 (30.00)
1.378 (35.00)
1.575 (40.01)
0.100 (2.54)
12 places
0.125 (3.18)
0.161 (4.09)
0.063 (1.60)
1.200 (30.48)
1.378 (35.00)
All Dimensions in Inches [mm]
PIN CONNECTIONS
PIN NUMBER
1
FEATURE
Vout +
Vout -
N/C
Trim
N/C
N/C
N/C
On/Off
N/C
N/C
Vin -
Vin +
PROTECTION
Short circuit
Overvoltage
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2, input voltage
and current requirements
Continuous
Latching clamp
2
3
4
5
6
7
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
8
9
International Safety Standard Approvals
10
UL/cUL 1950 3rd edition. File No. E135734
TÜV
11
TÜV Rheinland. File No. 10401-3336-35841. Licence No. 40004290
12
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items:
Application Note
Longform Data Sheet
www.artesyn.com
File Name: sxe15s.pdf Rev (02): 08 Dec 2005