RESISTORS
RESISTORS
METAL FILM
EXTEnDED POWER RATIng
MFS 1/2
STRUCTURE
1
2
3
4
5
6
7
Ceramic core
Trimmed metal film
Steel cap
(Cu, Sn plated)
Lead wire
Welding joint
Expoxy resin overcoating
Marking
IDEnTIFICATIOn
PRODUCT CODE
MFS 1/2
COATIng COLOR
Light Grey
MARKIng
Color Code
(R-value and
tolerance)
All these products have Pb-free terminations and
meet EU-RoHS and China-RoHS requirements
TYPE DESIgnATIOn (HOW TO ORDER)
MFS
PRODUCT
CODE
1/2
POWER RATING
0.6 Watt
T .C .R .
C: ±50ppm/K
D: ±100ppm/K (new)
TERMINATION
SURFACE
MATERIAL
C: SnCu
TAPING &
FORMING
PACKAGING
A: Ammo
R: Reel
NOMINAL
RESISTANCE
D, F: 4 digits
G, J: 3 digits
RESISTANCE
TOLERANCE
D, F, G, J
*Please see “PACKAGING”
FEATURES
■
■
■
■
■
■
■
■
Size 0207 with 0.6 Watt power rating
High precision and low T .C .R . metal film resistor
Automatic insertion is applicable
Variable formings are available
Excellent long term stability
Meets or exceeds IEC 60 115-8, JIS C 5201-1
Rated ambient temperature: +70°C
Operating temperature range: -55°C ... +155°C
DIMEnSIOnS (mm)
TYPE
MFS 1/2
L
6.3 ± 0.5
C Max.
7.1
D
2.3 ± 0.3
d (nominal)
0.6
l
30 ± 3
DERATIng CURVE
Ambient temperature (°C)
RATIng
DIn
SIZE
0207
TYPE
T.C.R.
(ppm/K)
POWER
RATIng*
0.6 W
MAX.
WORKIng
VOLTAgE
350 V
MAX.
OVERLOAD
VOLTAgE
DIELECTRIC
WITH-
STAnDIng
VOLTAgE
RESISTAnCE RAngE
E24 • E96
D (±0.5%)
10 Ω ... 1 MΩ
E24 • E96
F (±1%)
g (±2%)
2.2 Ω ... 2.2 MΩ
E24
J (±5%)
MFS 1/2 C C
C (± 50)
MFS 1/2 D C
D (± 100)
700 V
500 V
* For resistors operated in ambient temperature over +70°C, power rating shall be derated like shown in above „DERATING CURVE“.
Rated voltage = Power rating x resistance value or max . working voltage, whichever is lower .
z
Preferred
TOLerANCe
EUROPE GmbH • Kaddenbusch 6 • D-25578 Dägeling / ITZEHOE • PHONE: +49 (0) 48 21 / 89 89-0 • FAX: +49 (0) 48 21/ 89 89 89 • Internet: www.koaeurope.de
112
Revision: 05. Nov. 2008
Specifications given herein may be changed at any time without prior notice .
Please confirm technical specifications before you order/or use .
Contact our sales representatives before you use our products for applications including
automotives, medical equipment and aerospace equipment . Malfunction or failure of the
products in such applications may cause loss of human life or serious damage .
D
C
T52
A
*
1002
F
Contact us when you have
control request for environmental
hazardous material other
than the substance specified by
EU-RoHS