EEWORLDEEWORLDEEWORLD

Part Number

Search

EXA40-48S3V3J

Description
40 W High Efficiency DC-DC Converters
File Size131KB,3 Pages
ManufacturerEmerson
Download Datasheet View All

EXA40-48S3V3J Overview

40 W High Efficiency DC-DC Converters

EXA40 Series
DC-DC CONVERTERS
Single output
40 W High Efficiency DC-DC Converters
1
High efficiency topology, 91% typical at 5 V
Approved to EN60950, UL1950, CSA C22.2 No. 950
Operating ambient temperature of -40 °C to +70 °C
(natural convection)
Complies with ETS 300 019-1-3/2-3
Complies with ETS 300 132-2 input voltage and current
requirements
Fully compliant with ETS 300 386-1
RoHS Compliant
The EXA40 Series, comprising 8 different models is targeted specifically at the
telecommunications, industrial electronics, mobile Telecommunications and distributed
power markets. The series offers two wide input voltage ranges of 18 Vdc to 36 Vdc and
36 Vdc to 75 Vdc. Typical efficiencies are 91% for the 5 V output, 88% for the 3.3 V, 86%
for the 2.75 V and 84% for the 1.8 V. The series has been designed primarily for
Telecommunications applications and complies with ETS 300 386-1 immunity and emission
standards for high priority of service class. In addition the series complies with ETS 300
019-1-3 environmental standards (all classes) including shock, vibration, humidity and
thermal performance. A high level of reliability has been designed into all models through
the extensive use of conservative derating criteria. Remote enable and overtemperature
shutdown are included as standard while true latching OVP is available as an option.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
(See Note 10)
Voltage accuracy
Line regulation
Load regulation
Minimum load
Ripple and noise
20 MHz bandwidth
Temperature coefficient
Transient response
Peak dev. settling time
Short circuit protection
(See Note 5)
INPUT SPECIFICATIONS
Input voltage range
Input current
UVLO turn ON voltage
UVLO turn OFF voltage
Start-up time
24 Vin nominal
48 Vin nominal
No load
Remote OFF
All inputs (See Note 4)
All inputs (See Note 4)
Nominal line
18-36 Vdc
36-75 Vdc
100 mA max.
4 mA max.
94%
86%
50 ms
Open Collector
ref. to -input
4.5 Vdc
<1.0 Vdc
50% to 75% and back
to 1.0%, no external cap.
Low line to high line
Full load to no load
2.75 V, 3.3 V, 5 V
1.8 V output
±10% min.
+12/-17% min.
±1.0%
+0.05%
+0.20%
0%
100 mV pk-pk max.
20 mV rms max.
±0.01%/°C
100 mV
250 µs
EMC CHARACTERISTICS (Cont.)
Radiated emissions
ESD air
ESD contact
Surge (500 V)
Fast transients
Radiated immunity
Conducted immunity
EN55022 (See Design Note 102) Level B
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3, 4
EN61000-4-4, level 3, 4
EN61000-4-3, level 3
EN61000-4-6, level 3
GENERAL SPECIFICATIONS
Efficiency
Basic insulation
Input fuse 24 V
Input fuse 48 V
Switching frequency
Approvals and
standards
(See Notes 7, 8, 9)
Weight
MTBF
(See Design Note 102)
Input/output
(See Note 8)
Fixed
See table
1500 Vdc
3.5 A slow blow
2.0 A slow blow
300 kHz
EN60950
UL1950
CSA C22.2 No. 950
25 g (0.88 oz)
250,000 hours
Continuous
automatic recovery
MIL-HDBK-217
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
temperature
Non-operating
Loss of Function
Self-Recovery (LFS)
-40 °C to +70 °C,
See curves
-55 °C to +105 °C
75 °C to +85 °C
Over temperature
shutdown
ETS 300 019-2-3
Air temperature
Active high remote ON/OFF
Logic compatibility
ON
OFF
INPUT SPECIFICATIONS
ETS 300 386-1 table 5
Conducted emissions
(See Design Note 102)
Open circuit voltage
Relative humidity
Vibration, Class 3M5
EN55022, internal filter and
two 4 µF film capacitors
EN55022, external filter
Level A
Level B
Shock, Class 3M5
Classes T3.1 to T3.5
Low: IEC 68-2-1
-40 °C
High: IEC 68-2-2
+70 °C
Change: IEC 68-2-1
-40 °C to +70 °C
IEC 68-2-56
10% to 100% RH
IEC 68-2-30
Condensation
IEC68-2-6
2-9 Hz, 3 mm disp.
9-200 Hz 1 g
MIL-STD-202F
Method 204 cond. A
IEC-68-2-29
MIL-STD-202F
Method 213B cond. A
File Name: exa40.pdf Rev (02): 09 Dec 2005
How to Place an Inductor on a Switch Mode Power Supply PCB
Question: Where should the coil be placed?answer:Switching regulators for voltage conversion use inductors to temporarily store energy. These inductors are usually very large and must be located in th...
eric_wang Power technology
FPGA implementation of audio embedded in SDI.pdf
FPGA implementation of audio embedded in SDI.pdf...
zxopenljx EE_FPGA Learning Park
GPRS network structure
BTS (Base Transceiver Station) BTS can be regarded as a wireless modem, responsible for receiving and sending mobile signals BSC (Base Station Controller) MSC (Mobile Switching Center) is the core of ...
fish001 RF/Wirelessly
[UFUN Learning] The first program download and PWMLED test
It has been a while since I got the UFUN board. As I have been busy with work recently, I have not found time to take a look at this board. Overall, the UFUN development board is relatively small, eas...
常见泽1 Integrated technical exchanges
Does the color of the PCB affect the SMT patch?
Recently I found on the Jiali Chuang forum that Jiali Chuang only posts green boards, so I was wondering if the color of the board has an effect on the patch, or if Jiali Chuang only posts green for c...
PCB我不会 PCB Design
Today at 10:00 AM, live broadcast with prizes: Cytech & ADI - Gigabit digital isolators for video, converters, and communications
Click to enter the live broadcast Live broadcast time: October 22, 2020, 10:00-11:30 amLive broadcast topic: Gigabit Digital Isolators for Video, Converters, CommunicationsLive Introduction:Various re...
dancerzj Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号