Part Number

Search

247XCXL-0.2F24VAC

Description
Off-Delay Relay, 3PDT, Momentary, 5000mW (Coil), 10A (Contact), 28VDC (Contact), 0.2s, AC Input, AC/DC Output, Through Hole-Straight Mount
CategoryMechanical and electronic products    relay   
File Size447KB,2 Pages
ManufacturerStruthers-Dunn
Download Datasheet Parametric View All

247XCXL-0.2F24VAC Overview

Off-Delay Relay, 3PDT, Momentary, 5000mW (Coil), 10A (Contact), 28VDC (Contact), 0.2s, AC Input, AC/DC Output, Through Hole-Straight Mount

247XCXL-0.2F24VAC Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC):20.4 V
body width37.2 mm
body height95.2 mm
Body length or diameter66.8 mm
Coil current (AC) maximum value0.208 A
Coil power5000 mW
Maximum coil voltage (AC)24 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
timed delay0.2 s
Manufacturer's serial number247
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
physical size66.8mm X 37.2mm X 95.2mm
GuidelineCSA; UL
Relay actionMOMENTARY
Relay function3PDT
Relay typeOFF-DELAY RELAY
surface mountNO
Termination typeSOLDER
Base Number Matches1
246/247 Series - Timer Delay Relay
DPDT, 4PDT,6PST, 10 Amp
Rugged, industrial time delay versions of the popular 219 series. Contacts can be configured up
to four pole double throw or six pole single throw. Time ranges are adjustable over a 1:10 range.
Knob adjustment and integral hold down clip are standard. A large option list makes this product
easily customized for special applications.
E13224
GENERAL SPECIFICATIONS (@ 25° C)
Timing:
Functions Available
Time Range
Timing Adjustment
Timing Repeatability
(Constant voltage and temperature)
Reset Time maximum
Input Pulse Length minimum
Contacts:
Contact Configuration
Contact Material
Contact Rating
120 / 240VAC Resistive
28VDC Resistive
Motor 120VAC
Motor 240VAC
Minimum Contct Load
Contact Resistance, Initial
Coil:
Coils Available
Nominal Coil Power
Input Voltage Tolorance -AC
Input Voltage Tolorance -DC
Transient Protection
Reverse Polarity Protection
Duty
Dielectric Strength:
Across Open Contacts
Between Mutally Insulated Points
Insulation Resistance
Temperature:
Operating
Storage
Life Expectancy:
Electrical (full load operations)
Mechanical (no load operations)
Miscellaneous:
Mounting Position
Mating Socket
Accessories
Enclosure
Weight
On-delay, Off-delay
Up to 10 minutes
Knob
3%
150mS
50mS
DPDT, 4PDT, 6PST
Silver Alloy Gold Diffused
10 Amp / 5 Amp
10 Amp
-
-
500mW
100 milliohms max @ 6VDC, 1A
AC and DC
5VA 2.5W
85% to 110% of nominal
80% to 110% of nominal
Yes
Yes
Continuous
500Vrms
1500Vrms
1,000 Mohms min @ 500VDC
-20 to 70°C (-4 to 158°F)
-40 to 105°C (-40 to 221°F)
100,000
10,000,000
Any
12 pin =27390, 27390D
14 pin = 33377, 33377D
Hold down clip integral to relay
Clear Polycarbonate
8.6oz (244 grams)
with socket
Industrial Pin Out
Note: SM = Single make
DM = Double make
Voltage
Make
Carry
Resistive Inductive
120VAC
30 Amp 10 Amp 10 Amp
3 Amp
240VAC
30 Amp 10 Amp 5 Amp
1 Amp
24VDC
30 Amp 10 Amp 10 Amp
5 Amp
28VDC
30 Amp 10 Amp 10 Amp
3 Amp
125VDC
30 Amp 10 Amp 0.5 Amp
0.1 Amp
For versions with suffix “69” permant magnet blowouts
Voltage
Make
Carry
Resistive Inductive
125VDC (SM) 30 Amp 10 Amp 1.5 Amp
0.5 Amp
125VDC (DM) 30 Amp 10 Amp
4 Amp
1.5 Amp
250VDC (SM) 30 Amp 10 Amp
0.5 Amp 150 mAmp
250VDC (DM) 30 Amp 10 Amp 1.5 Amp
0.5 Amp
246/247 Contact Load Specifications
7/9
www.struthers-dunn.com
(843) 664-3303
Last day! Answer questions to win prizes! Practical sharing | Design a reliable switching power supply from scratch
Is power supply design difficult? I believe the answer is yes. However, as an essential component of electronic products, many people want to learn it well. First, let's take a look at the definition ...
EEWORLD社区 Switching Power Supply Study Group
How to detect whether the switching power supply transformer is good or bad?
[p=30, null, left][color=rgb(34, 34, 34)][font="][size=4][color=#000000]Switching power transformer[/color]Switching power transformer is a power transformer with a switching tube added. In addition t...
灞波儿奔 Analogue and Mixed Signal
micropython update: 2021.4
stm32/boards/pllvalues.py: Relax PLLQ constraints on STM32F413 MCUs. stm32/powerctrl: Support using PLLI2C on STM32F413 as USB clock source. stm32/powerctrl: Allow a board to configure AHB and APB clo...
dcexpert MicroPython Open Source section
The battery voltage is pulled down
The battery voltage is pulled down, the BAT battery voltage is 4.21V, When MCU_CTL is at a low level (short-connected to GND and then released), Q5 and Q1 are turned off, and the BAT_OUT output is alr...
QWE4562009 Discrete Device
Is there any abnormal sound from the common mode inductor?
4V350W dual-tube forward, the customer requires EMI to pass CLASS B with a margin greater than 6dB, two levels of common mode inductors T20_10_10 are added in front, and now both conduction and radiat...
台强陈剑 Switching Power Supply Study Group
bq27411-g1 (single-cell fuel gauge) bq27541 (single-cell fuel gauge) bq27546-g1 (single-cell fuel gauge)
bq27411-g1 (single-cell fuel gauge) bq27541 (single-cell fuel gauge) bq27546-g1 (single-cell fuel gauge) Which of these three fuel gauges from TI are you familiar with? For example, after replacing th...
QWE4562009 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号