FEATURES
Multiple Case Sizes
-
High Voltage
–
High Current
APPLICATIONS
Filtering
–
Switching Power Supplies
Operating Temperature
Range
Capacitance Tolerance
Surge Voltage
Dissipation
Factor
tan δ
(120 Hz)
WVDC
SVDC
WVDC
D<30
D=35
D>40
-40°C to +85°C
+20% at 120 Hz, 20°C
16
25
35
50
63
80
100 160 200 250 350
400
20
32
44
63
79
100
120 200 250 300 400
450
16
25
35
50
63
80
100 160 200 250 350
400
.4
.3
.25
.2
.15
.15
.15
.1
.1
.1
.15
.15
.4
.3
.25
.2
.15
.15
.15
.15
.15
.15
.15
.15
.5
.45
.4
.35
.3
.25
.2
--
--
--
--
--
For capacitances above 33000uF, add to DF value (Capacitance-33000) *0.1
10000
450
500
450
.15
.15
--
Leakage Current
@20C, Rated WVDC applied
Time
16
4
15
25
3
10
35
3
8
50
2
6
63
2
6
80
2
5
5 Minutes
3√CV
100
2
5
160
6
9
200
6
9
250
6
9
350
8
12
400
8
12
450
8
12
Impedance
Ratio
(120 Hz)
WVDC
-25°C/+20°C
-40°C/+20°C
3000 hours with rated voltage and rated ripple current applied at 85°C
Load Life
Shelf Life
Ripple Current
Multipliers
WVDC
<100
>160
Capacitance Change
Dissipation Factor
Leakage Current
Capacitance Change
Dissipation Factor
Leakage Current
60
0.8
0.8
120
1.0
1.0
400
1.1
1.1
<20% of initial measured value
<200% of maximum specified value
<100% of maximum specified value
<20% of initial measured value
<200% of maximum specified value
<100% of maximum specified value
1000 hours at 85°C with no voltage applied
Frequency (Hz)
1k
1.15
1.15
10k+
1.25
1.47
40
1.8
1.8
Temperature (°C)
60
1.4
1.4
70
1.2
1.2
85
1.2
1.2
Feb-17