UPM SERIES - NON-ISOLATED, 40 WATT
DESCRIPTION
UPM non-isolated DC/DC buck converters deliver high
power and excellent transient response in a compact
1.0” x 2.0” x 0.475” package. The UPM can provide up
to 40 Watts of output power at 12A output current, and
output voltages from 1.2 to 3.3V. Featuring open-
frame, 100% surface-mount construction and high
efficiency, the UPM excels in difficult thermal
environments.
FEATURES
• High Power Converter
• High Efficiency
• Excellent Transient
Response
• Sense Pins
• Surface-Mount
Construction
• Voltage Trim
• Low Profile
• Water Washable
TECHNICAL SPECIFICATIONS
Input
Voltage Range
3.3 VDC Nominal
5.0 VDC Nominal
3.0 - 3.6 VDC
4.5 - 5.5 VDC
Output
Setpoint Accuracy
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
Load Regulation I
out
Min.- I
out
Max., V
in
Nom.
Ripple and Noise, DC - 200 MHz
Remote Sense Headroom
Current Limit Protection Type
Current Limit Threshold Range, % of I
out
Rated
Short Circuit Protection Type
V
out
Ramp Up Rate, Minimum
±1%
1% V
out
1% V
out
50 mV Pk-Pk
0.25 V
Hiccup
130%
Latching
0.5V/ms
Efficiency vs. Load (5V Input)
94
92
90
EFFICIENCY %
88
86
84
82
EFF. (4.5V)
EFF. (5V)
EFF. (5.5V)
General
Switching Frequency
Temperature Coefficient
Baseplate Operating Temperature
Storage Range
Internal Input Capacitance
Recommended External Capacitance
Input
Output
Load Capacitance Compensation
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF
†
(Bellcore TR-NWT-000332)
Safety
Weight (approx.)
200 kHz
50 ppm/°C
0 to +100°C
-40 to +100°C
500
µF
Max.
200
µF/A
I
out
80
78
10
20
30
40
50
60
70
80
90
100
LOAD %
200
µF/A
I
out
User Selectable
95%
5 g, 10 - 55 Hz
2.9 x 10
6
hrs
UL, CSA, EN60950
0.9 oz
Notes
†
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
C-96
UPM SERIES - NON-ISOLATED, 40 WATT
MODELS - (See the last page of this file for options.)
Vin
(Volts)
3.3
3.3
3.3
3.3
5
5
5
5
5
5
Vin Range
(Volts)
3.0 - 3.6
3.0 - 3.6
3.0 - 3.6
3.0 - 3.6
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
Iin Max.*
(Amps)
5.2
6.3
7.5
8.5
4.1
5.1
6.0
6.8
7.9
10.0
Vout
(Volts)
1.2
1.5
1.8
2.1
1.2
1.5
1.8
2.1
2.5
3.3
Iout Rated
(Amps)
12
12
12
12
12
12
12
12
12
12
Efficiency
Typ. **
78%
79%
81%
82%
78%
79%
81%
82%
84%
88%
Model
UPM301.2
UPM301.5
UPM301.8
UPM302.1
UPM501.2
UPM501.5
UPM501.8
UPM502.1
UPM502.5
UPM503.3
Denotes advanced product release. Consult factory for product availability.
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
2.00"
(50.8mm)
0.025" SQ.
(0.6mm)
0.750"(19.0mm)
1
5
6
3
1.00"
(25.4mm)
BOTTOM VIEW
7
8
9
10
0.625"(15.9mm)
0.525"(13.3mm)
0.425"(10.8mm)
0.325"(8.3mm)
0.225"(5.7mm)
0.125"(3.2mm)
4
0
2
DIA 0.060"
(1.5mm)
0.12"
0.475"
(12.1mm)
-0.125"(-3.2mm)
-0.125" 0
(-3.2mm)
1.475"
(37.5mm)
1.750"
(44.5mm)
(3.0mm)
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
9.4
6.6
4.3
3.2
2.7
°C/W
°C/W
°C/W
°C/W
°C/W
Pin
1
2
3
4
5
6
7
8
9
10
Function
-V
in
+V
in
-V
out
+V
out
-Vsense
Ground
Loop Comp.
No Conn.
Trim
+Vsense
Tolerances
Inches:
.XX ± 0.020
.XXX ± 0.010
Pin:
± 0.002
(Millimeters)
.X ± 0.5
.XX ± 0.25
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
± 0.05
(Dimensions as listed unless otherwise
specified.)
C-97
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
Negative Logic
Lucent Compatible Trim
Terminal Strip
Trim
Enable
Trim and Enable
Current Share
Headerless
SUFFIX
N
T
TS
1
2
3
4
Y
APPLICABLE SERIES
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
HAS, HBD, HBS, HES, QBS, QES
XWS, XWD, XWT
IAS, LES
IAD, IAS, LES, SMS
IAS, LES
SMS
Encapsulated EWS, IWS, OWS
REMARKS
TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
PIN LENGTH AND HEATSINK
OPTIONS
0.110” (2.8mm) Pin Length
0.150” (3.8mm) Pin Length
0.24” (6.1mm) Horizontal Heatsink
0.24” (6.1mm) Vertical Heatsink
0.45” (11.4mm) Horizontal
Heatsink
0.45” (11.4mm) Vertical Heatsink
0.95” (24.1mm) Horizontal
Heatsink
0.95” (24.1mm) Vertical Heatsink
8
9
1H
1V
2H
2V
3H
3V
All Units (Except SMS)
All Units (Except SMS)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
Standard Pin Length is 0.180”
(4.6mm)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS
Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS
The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
C105