EEWORLDEEWORLDEEWORLD

Part Number

Search

CO-725G37-VRL2ATFREQ2

Description
Sine Output Oscillator, 75MHz Min, 125MHz Max
CategoryPassive components    oscillator   
File Size102KB,1 Pages
ManufacturerVectron International, Inc.
Websitehttp://www.vectron.com/
Download Datasheet Parametric View All

CO-725G37-VRL2ATFREQ2 Overview

Sine Output Oscillator, 75MHz Min, 125MHz Max

CO-725G37-VRL2ATFREQ2 Parametric

Parameter NameAttribute value
MakerVectron International, Inc.
Reach Compliance Codecompliant
Other featuresOPTIONAL SUPPLY VOLTAGE 12V TO 24V; AT CUT CRYSTAL
Ageing0.3 PPM/YEAR
Frequency Adjustment - MechanicalYES
frequency stability0.3%
input power2.5 W
Manufacturer's serial numberCO-725
Installation featuresTHROUGH HOLE MOUNT
offset frequency1 kHz
Maximum operating frequency125 MHz
Minimum operating frequency75 MHz
Maximum operating temperature75 °C
Minimum operating temperature-55 °C
Oscillator typeSINE
Output impedance50 Ω
Output level2.8284 V
Oven power supply voltage15V
phase noise-135 dBc/Hz
physical size50.8mm x 50.8mm x 31.75mm
Nominal supply voltage15 V
surface mountNO
Preheating power4.5 W
[2022 Digi-Key Innovation Design Competition] CAN Communication Data Display Terminal
1. IntroductionDuring the debugging process of the device, you often need to check some data and operating status of the device. Use the STM32H745 development board to display the main data and status...
TL-LED DigiKey Technology Zone
How to design high frequency (>100K) ultrasonic sensor processing circuit
There are many high-frequency ultrasonic sensors for sale on the Internet, but they do not have the relevant sensor processing circuits. How can we design this kind of circuit? The sensor doesn’t seem...
yichun417 Sensor
A design scheme of smart water meter controlled by NFC
Introducing a national invention patent - a smart water meter with one card. The patent was applied by Zhengzhou Leyuan Electronic Technology Co., Ltd. and was authorized on January 9, 2018.Contents T...
fish001 Microcontroller MCU
Oscilloscope waveform jitter can be turned into stable waveform by setting trigger properly
There are generally two reasons for oscilloscope waveform jitter. One is that the signal is not synchronized, which is a problem with the oscilloscope trigger setting. The other is that the signal its...
Micsig麦科信 Test/Measurement
How to measure the noise floor of an oscilloscope
Signal integrity is the main criterion for measuring signal quality with an oscilloscope, especially when we need to observe small signals or slight changes in large signals, signal integrity becomes ...
Micsig麦科信 Test/Measurement
Xintang M2354 Fault Injection Attack Protection
Abstract Shortly after Arm, a global mobile computing IP giant, launched its new isolation technology TrustZone, the hacker community took the opportunity to launch its own attack against the architec...
火辣西米秀 Domestic Chip Exchange

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号