Motor Starting and other intermittent AC applications
Proudly Made In U.S.A.
The MS motor start aluminum electrolytic capacitor is used to provide the torque necessary to start AC motors and can be used in other intermittent
AC applications. The capacitor comes in all popular styles with a variety of terminal configuration choices. Mallory Motor Start Capacitors are
designed in accordance with EIA-463-B. The metal case units are covered with a plastic sleeve (PVC) to provide electrical insulation.
4411 South High School Road
Indianapolis,IN 46241
Phone: (317) 612-1000
(800) 625-4369
Fax: (317) 612-1010
Mal
lo
AC
Capacito
ry
LC
rL
®
IS
O9
0
002
A124
MALLORY AC CAPACITOR LLC
www.mallory-ac.com
Type MS
Case
Code
D
( 0.015)
Standard Terminal Layouts & Resistor Layout
Inches
L
(+0.020, -0.030)
C
(Ref.)
1
/
2
1
/
2
1
/
2
5
/
8
5
/
8
7
/
8
7
/
8
7
/
8
Millimeters
D
( 0.38)
L
(+0.51, -0.76)
C
(Ref.)
1
2
3
4
5
6
7
8
1-
7
/
16
1-
7
/
16
1-
7
/
16
1-
13
/
16
1-
13
/
16
2-
1
/
16
2-
1
/
16
2-
9
/
16
(1.4375)
(1.4375)
(1.4375)
(1.8125)
(1.8125)
(2.0625)
(2.0625)
(2.5625)
2-
3
/
4
3-
3
/
8
4-
3
/
8
3-
3
/
8
4-
3
/
8
3-
3
/
8
4-
3
/
8
4-
3
/
8
(2.750)
(3.375)
(4.375)
(3.375)
(4.375)
(3.375)
(4.375)
(4.375)
(.500)
(.500)
(.500)
(.625)
(.625)
(.875)
(.875)
(.875)
36.51
36.51
36.51
46.04
46.04
52.39
52.39
65.09
69.85
85.73
111.13
85.73
111.13
85.73
111.13
111.13
12.70
12.70
12.70
15.88
15.88
22.23
22.23
22.23
Solder Lug Terminals
(SL)
(All Cases)
.125
(Ref)
C
Single Disconnect Terminals
(SQC)
(All Cases)
C
Standard
Dual Disconnect Terminals
(DQC)
(All Cases)
C
Dual Disconnect Terminals
W/Solder Lug Terminal
(DQCS)
(Case 4, 5, 6, 7 & 8 only)
C
L
.0625
(Ref)
.0625
(Ref)
.0625
(Ref)
D
Mounting Accessories
HB Brackets
EIA
Case Code
Dimensions (Ref.)
PL and PLA End Caps
Catalog Number
A
3-
3
/
8
"
4-
1
/
64
"
5-
1
/
64
"
B
1-
11
/
64
"
1-
13
/
16
"
2-
23
/
32
"
C*
7
/ "
8
1
/ "
1-
2
1-
25
/
32
"
D
1.258
1-
37
/
64
"
2-
5
/
64
"
Wire Hole
Toward Bracket
Wire Hole
Away From Bracket
EIA
Case Code
A
Dimension
HB2
HB4
HB8
1
2-4-6
3-5-7-8
PL3
PL6
PL8
PL10
PLA3
PLA6
PLA8
PLA10
1-2-3
4-5
6-7
8
1-
7
/
16
"
1-
13
/
16
"
2-
1
/
16
"
2-
9
/
16
"
Material: .042 spring steel
with black parkerized finish.
.3125 R
.2188 R
* Center-to-center dimension.
.375
PL
A
.9375 Space
D
.191 R
.750
1.375
*C
.094
.375
PLA
B
A
.230
.234
A
.875
1.1875
HB brackets are used with PL or PLA end caps. The bracket is assembled to the motor or any suitable surface by two screws in line at any convenient position within
the center-to-center dimension (C) shown in the chart. The PL end cap is placed in position and the entire assemby snapped into place with the connecting wires
brought through the bracket hole. Use PLA style caps if the wire is to be direced away from the bracket. (Example: PLA3).
End caps and brackets are shipped loose and should be ordered separately.
Contact the factory for information about wire leads and sub-assemblies.
2
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
Ratings Charts
MSA - Type 2 Standard Duty Ratings
Highlighted case sizes per EIA-463-B
Other case sizes listed are available from Mallory
and also meet EIA-463-B Type 2 test specifications.
MFD
21-25
25-30
30-36
36-43
43-52
47-56
53-64
64-77
72-87
88-106
108-130
124-149
130-156
145-174
161-193
189-227
216-260
233-280
243-292
270-324
324-389
340-408
378-455
400-480
430-516
460-552
540-648
590-708
645-774
708-850
720-864
800-960
815-978
829-995
850-1020
1000-1200
1020-1224
1175-1410
1280-1536
1326-1590
110 Vac
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1 or
2
1 or
2
1 or
2
1 or
2
1 thru
3
1 thru
4
2 thru
4
2 thru
4
2 thru
4
2 thru
4
4 or
5
4 or
5
4 thru
7
4 thru
7
4 thru
7
4 thru
7
4 thru
7
4 thru
8
4 thru
8
5 thru
8
5 thru
8
5 thru
8
5 thru
8
7
125 Vac
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1or
2
1 or
2
1 or
2
1 thru
3
1 thru
3
2 thru
4
2 thru
4
2 thru
4
2 thru
4
2 thru
4
2 thru
4
4 or
5
4 or
5
4 thru
7
4 thru
7
4 thru
7
4 thru
7
4 thru
8
5 thru
8
5 thru
8
5 thru
8
5 thru 8
5 thru 8
7
7
165 Vac
1
1
1
1
1
1
1
1
1
1 or
2
1 or
2
1 or
2
2 thru
4
2 thru
4
2 thru
4
2 thru
4
2 thru
4
2 thru
5
2 thru
5
2 thru
5
4 thru
7
4 thru
7
4 thru
7
4 thru
7
4 thru
8
4 thru
8
4 thru
8
5 thru
8
5 thru
8
5 thru
8
5 thru
8
7 or
8
7 or
8
7 or
8
7 or
8
7 or
8
7
220 Vac
1
1
1
1
1 or
2
1 or
2
1 or
2
1 thru
4
1 thru
4
1 thru
4
1 thru
4
2 thru
5
2 thru
5
2 thru
7
4 thru
7
4 thru
7
4 thru
8
4 thru
8
4 thru
8
4 thru
8
7 or
8
7 or
8
7 or
8
7 or
8
8
8
8
8
8
250 Vac
1
1
1 or
2
1 or
2
1 or
2
1 or
2
1 thru
4
1 thru
4
1 thru
4
2 thru
5
4 or
5
4 or
5
4 or
5
4 thru
7
4 thru
7
4 thru
8
5 thru
8
5 thru
8
5 thru
8
5 thru
8
7 or
8
7 or
8
7 or
8
7 or
8
8
8
8
8
330 Vac
1 or
2
1 or
2
1 thru
4
1 thru
4
2 thru
4
2 thru
4
3 thru
5
4 or
5
4 or
5
4 thru
7
4 thru
8
4 thru
8
5 thru
8
5 thru
8
5 thru
8
7 or
8
7 or
8
7 or
8
7 or
8
7 or
8
8
8
8
8
8
8
MSB - Type 1 Heavy Duty Ratings
EIA-463-B does not specify case sizes for Type 1
Case sizes listed are available from Mallory
and also meet EIA-463-B Type 1 test specifications.
MFD
MFD
110 Vac 115 Vac 125 Vac Vac Vac 220 Vac250 Vac
250 Vac 330 Vac
330 Vac
110 Vac
125 Vac
165 165
220 Vac
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
or
or
or
or
or
or
4
4
5
or
or
or
5
7
7
7
7
7
7
8
8
8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
or
or
or
4
4
4
5
or
or
or
or
7
7
7
7
7
7
8
8
8
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
3 or 4
3 or 4
3 or 4
3 or 4
3 or 4
4 or 5
4 or 5
5 thru 7
5 thru 7
5 thru 7
5 thru 7
5 thru 7
7
7
7
7
8
8
8
8
8
8
8
8
1
1
1
1
1
1
1 or 2
4
4
4
4
5
5
5 thru 7
5 thru 7
7 or 8
7
7
8
8
8
8
8
8
8
8
1
1
1
2
2
2
3 or 4
4
4
4 or 5
5
5
5
5
7
7
7
8
8
8
8
8
8
8
8
1
1 or 2
2
2
4
4
4
4
4 or 5
5
5
5
6
7
8
8
8
8
8
8
21-25
25-30
30-36
36-43
43-52
47-56
53-64
64-77
72-87
88-106
108-130
124-149
130-156
145-174
161-193
189-227
216-260
233-280
243-292
270-324
324-389
340-408
378-455
400-480
430-516
460-552
540-648
590-708
645-774
708-850
720-864
800-960
815-978
829-995
850-1020
1000-1200
1020-1224
1175-1410
1280-1536
1326-1590
2
2
3
3
3
3
3
3
4
4
4
4
3
3
3
4
4
4
5
5
5
6
6
6
5
6
6
6
6
7
7
7
Part Number Nomenclature
Standard Part Number
Mallory Type Designation
Identifies the basic capacitor design;
MS
A
1
R
10
161
N
Performance
A = EIA Type 2
B = EIA Type 1
S = Special
Case Code
(See standard ratings page)
Case Type
R = Recessed (Standard).
Voltage Rating
10 = 110
22 = 220
12 = 125
25 = 250
16 = 165
33 = 330
Minimum Capacitance
Expressed in microfarads.
Always 3 or 4 digits.
Resistor
N = No resistor (Standard)
R = With Resistor (15k , 2 Watt is standard)
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
3
Metal Case AC Motor Start Capacitors
Maximum Capacitance for Aluminum Case Designs
per EIA ratings Type 2
Case Code
A1
A2
A3
B2
B3
C2
C3
C4
D2
D3
D4
E3
E4
D x L
(mm)
25 x 45
25 x 61
25 x 75
30 x 61
30 x 75
35 x 61
35 x 75
35 x 101
40 x 61
40 x 75
40 x 101
45 x 75
45 x 101
C
(mm)
10.16
10.16
10.16
10.16
10.16
12.7
12.7
12.7
15.9
15.9
15.9
15.9
15.9
110 Vac
161
243
324
324
460
460
645
850
590
850
1280
1020
1500
125 Vac
145
189
270
270
400
430
590
850
590
829
1175
1020
1410
165 Vac
108
130
189
189
270
270
378
540
400
540
800
645
1000
108
108
161
161
233
324
216
270
430
378
540
72
108
161
124
161
243
216
270
53
72
108
88
108
161
145
189
220 Vac
250 Vac
330 Vac
Insulation hi-pot test is 2000 Vac between metal case and metal foil
wrapped around sleeve for 1 second.
L
2.0
7.7mm Max.
7.7mm Max.
C
0.5
D
1.0
C 0.5
Solder Lug Terminals
(SL)
(25,30mm Cases)
Standard Dual Disconnect Terminals
(DQC)
(35,40,45mm Cases)
Note: Add 1.0mm maximum to diameter and 1.0mm
maximum to length for PVC insulation sleeve.
Metal Case Part Number Nomenclature
Standard Part Number
Mallory Type Designation
Performance
L = EIA Type II
(Standard)
M = EIA Type I
(Special)
Contact Mallory for size information.
G = Extended Run (Special)
Minimum Capacitance
Expressed in Microfarad
Always in 3 or 4 Digits
Tolerance
D = -0 + 20%
Voltage Rating
3 Digits
Case Code
(See Table)
Resistor
N = No resistor (Standard)
R = With Resistor (15k , 2 Watt is standard)
Sleeve
3 = Blue PVC
MS
L
189
D
110
A2
N
3
4
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
Application Guide for Plastic and Metal Case
Figure A: Type 2 (MSA)
Rated
Voltage Test
Volts AC (rms)
Capacitance Rating
(mfd)
From
To
Duty Cycle
Secs.
(On)
3
/
4
Figure B: Type 1 (MSB)
t
Duration of test
(no. of starts)
Rated
Voltage Test
Volts AC (rms)
Capacitance Rating
(mfd)
From
To
Duty Cycle
Secs.
(On)
3
/
4
3
/
4
3
/
4
3
/
4
3
/
4
3
/
4
3
/
4
3
/
4
3
/
4
3
/
4
3
/
4
3
/
4
Secs.
(Off)
Secs.
(Off)
{
Duration of test
(no. of starts)
110
125
165
220
250
330
21-25
130-156
270-324
400-480
590-708
1000-1200
21-25
108-130
161-193
243-292
400-480
645-774
21-25
108-130
130-156
233-280
378-454
21-25
37-56
88-106
161-193
270-324
21-25
36-43
72-86
108-130
216-259
21-25
25-30
36-43
72-86
108-130
124-149
243-292
378-454
540-648
850-1020
1326-1590
88-106
145-174
233-280
378-454
590-708
1326-1890
88-106
124-149
216-259
340-408
850-1020
43-52
72-86
145-174
243-292
460-552
30-36
64-77
88-106
189-227
430-516
21-25
30-36
64-77
88-106
270-324
1
1
1
1
1
3
/
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
29
1
/
4
59
89
119
179
239
29
1
/
4
59
89
119
179
239
59
89
119
179
239
59
89
119
179
239
59
89
119
179
239
59
89
119
179
239
50,000
50,000
33,500
25,000
16,500
12,500
50,000
50,000
33,500
25,000
16,500
12,500
33,500
33,500
25,000
16,500
12,500
33,500
33,500
25,000
16,500
12,500
33,500
33,500
25,000
16,500
12,500
33,500
33,500
25,000
16,500
12,500
{
110
125
165
220
250
330
21-25
130-156
270-324
400-480
590-708
1000-1200
21-25
108-130
161-193
243-292
400-480
645-774
21-25
108-130
130-156
233-280
378-454
21-25
37-56
88-106
161-193
270-324
21-25
36-43
72-86
108-130
216-259
21-25
25-30
36-43
72-86
108-130
124-149
243-292
378-454
540-648
850-1020
1326-1590
88-106
145-174
233-280
378-454
590-708
1326-1890
88-106
124-149
216-259
340-408
850-1020
43-52
72-86
145-174
243-292
460-552
30-36
64-77
88-106
189-227
430-516
21-25
30-36
64-77
88-106
270-324
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
29
1
/
4
29
1
/
4
29
1
/
4
29
1
/
4
29
1
/
4
29
1
/
4
29
1
/
4
29
1
/
4
29
1
/
4
29
1
/
4
29
1
/
4
29
1
/
4
59
59
59
59
59
59
59
89
89
89
59
59
89
89
119
59
59
59
89
119
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
40,000
40,000
40,000
40,000
40,000
40,000
40,000
33,500
33,500
33,500
40,000
40,000
33,500
33,500
25,000
40,000
40,000
40,000
33,500
25,000
t
The number of starts shown are reduced starts for accelerated
testing so that test time does not exceed 35 days. Type 2 capaci-
tors should be capable of 50,000 starts for ratings to 125 volts
and 40,000 starts for higher voltages. See section 3.0 for testing
procedures.
The number of starts shown are reduced starts for accelerated
testing so that test time does not exceed 35 days. Type 1 capaci-
tors should be capable of 75,000 starts for ratings to 125 volts
and 40,000 starts for higher voltages. See section 3.0 for testing
procedures.
If an application exceeds the duty cycles in Figure B, other meth-
ods of capacitor selection must be used, Contact Mallory for
assistance.
1.1 VOLTAGE RATING
The rated voltage of the capacitor must be greater than or equal
to the average voltage across the capacitor terminals during the
motor starting cycle. This is not necessarily the same as the mo-
tor line voltage. In addition, the cutoff voltage rating of the ca-
pacitor must be greater than or equal to the maximum voltage
attained across the terminals of the capacitor in actual service.
The maximum recommended cut-off voltages for the seven stan-
dard voltage ratings are as follows:
Rated
Maximum
Voltage (rms) Cut-Off Voltage (rms)
110
140
125
160
165
210
220
280
250
300
330
400
These ratings are based on the maximum capacitor temperature
of 65gC.
1.2 CAPACITANCE RATING
The capacitance is chosen to give the necessary starting torque
to the motor. The minimum capacitance value is the minimum
designed capacitance. The maximum capacitance is 20% more
than that value.
1.3 DUTY CYCLE
The duty cycle should be calculated for each application. It is the
ratio of the time the capacitor is on voltage to the total time of one
cycle. The duty cycles for the normal performance of Type 2
(MSA) capacitors are listed in Figure A. Mallory Type MSA
capacitors may be used in any intermittant application within their
temperature and voltage range where the duty cycle does not ex-
ceed that listed in the table in Figure A. This is in accordance
with the standards in EIA-463-B for Type 2 capacitors.
If a particular application exceeds the normal duty cycle, but does
not exceed the values listed in Figure B, an extra performance or
Type 1 (MSB) capacitor is required.
(Continued)
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
At this stage, I think everyone should have prepared for the competition. If you have any experience, please share it with us. If you are not prepared, it is a good opportunity to ask experienced peop...
1) Enable the general purpose input and output port peripheral (GPIO).
2) Configure the corresponding GPIO port as a normal input and output port (select the multiplexing function in I/O multiplexing)...
[i=s]This post was last edited by Jacktang on 2021-3-28 21:46[/i]Pico Explorer Base - Pimoroni's product
特性
Pico Explorer Base
Piezo speaker
1.54" IPS LCD screen (240 x 240)
Four user-controllable swi...
As devices within the Internet of Things (IoT) become more connected, and customer demands make firmware and software upgrades a critical product requirement, architecting for these updates is a criti...
[i=s]This post was last edited by boyk on 2022-4-28 14:15[/i]1. Product Introduction
An industrial control product consists of three parts: power supply, control board, and power board. The radiation ...
MicroPython has added support for STM32L432KC. You can find the previous NUCLEO_L432KC development board. [url]https://github.com/micropython/micropython/tree/master/ports/stm32/boards/NUCLEO_L432KC[/...
As a new type of flow meter product, the Verabar flowmeter is a brand-new average velocity flow probe that can perform high-precision flow measurement of gas, liquid and steam of different pipe diame...[Details]
There are many parameters that need to be measured in the production process of the paper industry, among which temperature is an important parameter. Therefore, it is very important to correctly sele...[Details]
Our Next Energy (ONE), an American energy storage technology company, recently announced that through its Gemini dual-chemistry battery technology, it has successfully enabled a BMW iX to run 608 mil...[Details]
The LED
industry and the traditional lighting industry are closely related to lighting technology. Like any other technology, lighting technology has its own special terms. These special terms...[Details]
PIC32MZ's flash memory supports live update, which is a brand new feature. All previous PIC microcontrollers, whether 8-bit or 16-bit, do not have this feature. I have written many bootloaders for PI...[Details]
Hello everyone, my name is Cristiano Amon, President of Qualcomm. I am honored to be able to give a speech at this year’s World VR Industry Conference. Over the past six months, connected technolog...[Details]
1. Brief introduction:
The ADC12 module is composed of the following parts: 16-channel analog input switches (8 external and 4 internal), ADC internal voltage reference source, ADC12 core, ADC clock ...[Details]
After the popularization of autonomous driving, the role of the driver will become history, and everyone will become a passenger. Every car will drive on the road in an orderly manner and keep a safe...[Details]
In recent years, LED lighting has gradually become familiar to people as a low-carbon, energy-saving and environmentally friendly lighting equipment. LED is favored by the industry for its rich color...[Details]
The control of the servo generally requires a 20ms time base pulse, and the high level part of the pulse is generally the angle control pulse part in the range of 0.5ms~2.5ms. Taking a 180-degree ang...[Details]
In many applications, the frequency conversion stage consists of a buffer, preferably with some additional voltage gain, a mixer, and some filtering. You can simply integrate the mixer functio...[Details]
1. Key points of timer/counter PWM design
According to the characteristics of PWM (Pulse Width Modulation (PWM: (Pulse Width Modulation) is a very effective mode of controlling analog circuits ...[Details]
According to a Gartner survey of 451 senior technology leaders in the second quarter of 2024, 57% of chief information officers (CIOs) said they were responsible for leading their company's artif...[Details]