EEWORLDEEWORLDEEWORLD

Part Number

Search

T2-613-1-X65+

Description
RF Transformer, 0.07MHz Min, 200MHz Max, ROHS COMPLIANT
CategoryPower management    transformer   
File Size88KB,1 Pages
ManufacturerMini-Circuits
Websitehttps://www.minicircuits.com
Environmental Compliance  
Download Datasheet Parametric View All

T2-613-1-X65+ Overview

RF Transformer, 0.07MHz Min, 200MHz Max, ROHS COMPLIANT

T2-613-1-X65+ Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerMini-Circuits
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresOHMS RATIO IS 1:1:2
maximum cutoff frequency200 MHz
minimum cutoff frequency0.07 MHz
high5.84 mm
Insertion loss3 dB
JESD-609 codee3
length7.62 mm
Installation featuresTHROUGH HOLE MOUNTED
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
physical sizeL7.62XB6.86XH5.84 (mm)
surface mountNO
Terminal surfaceTin (Sn) - with Nickel (Ni) barrier
Transformer typeRF TRANSFORMER
width6.86 mm

T2-613-1-X65+ Preview

Plug-In
50Ω
RF Transformer
0.07 to 200 MHz
Maximum Ratings
Operating Temperature
Storage Temperature
RF Power
DC Current
-20°C to 85°C
55°C to 100°C
0.25W
30mA
T2-613-1-X65+
T2-613-1-X65
Features
• wideband, 0.07 to 200 MHz
• single ended to balanced with impedance ratio selection
• also available with flat pack (W38)
& surface mount gull-wing (KK81) leads
CASE STYLE: X65
PRICE: $1.95 ea. QTY (1-9)
Pin Connections
PRIMARY DOT
PRIMARY
X1,Y5,Z3
X2,Y6,Z4
Applications
• HF/VHF
• test equipment
+ RoHS compliant in accordance
with EU Directive (2002/95/EC)
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications.
Transformer Electrical Specifications
RATIO
FREQUENCY
(MHz)
3 dB
MHz
1:1:2
0.07-200
0.07-200
INSERTION LOSS*
2 dB
MHz
0.1-100
1 dB
MHz
0.5-50
Outline Drawing
* Insertion Loss is referenced to mid-band loss, 0.4 dB typ.
Typical Performance Data
FREQUENCY
(MHz)
INSERTION
LOSS
(dB)
1.48
1.34
0.68
0.47
0.42
0.49
0.58
0.77
1.06
1.45
INPUT
R. LOSS
(dB)
8.88
15.76
20.56
25.22
27.19
23.67
18.52
15.39
13.44
13.77
Outline Dimensions (
A
.30
7.62
B
.27
6.86
C
.23
5.84
D
.010
0.25
E
.042
1.07
inch
mm
)
G
.100
2.54
F
.020
0.51
H
.05
1.27
J
.04
1.02
K
.11
2.79
L
.300
7.62
M
.35
8.89
wt
grams
0.50
0.07
0.20
0.63
2.00
9.20
29.09
63.25
100.24
149.06
200.00
T2-613-1-X65
INSERTION LOSS
3.0
Config. F
INSERTION LOSS (dB)
2.4
1.8
1.2
0.6
0.0
0.01
0.1
1
10
100
1000
FREQUENCY (MHz)
Distribution Centers
NORTH AMERICA 800-654-7949 • 417-335-5935 • Fax 417-335-5945 • EUROPE 44-1252-832600 • Fax 44-1252-837010
Mini-Circuits
®
INTERNET
http://www.minicircuits.com
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661
Mini-Circuits
ISO 9001 & ISO 14001
Certified
REV. A
M98898
T2-613-1-X65
IG/TD/CP
060807
What is this error?
Thu Nov 11, 2021 16:40:49: Failed to set configuration with MCU name STM8S105C6: SWIM error [30004]: Comm timeoutThu Nov 11, 2021 16:41:11: Failed to write chunk with size 128 at address 0x8000: SWIM ...
zhang520 stm32/stm8
I want to use CD4051 as the RX expansion of USART serial port, but how to calculate the baud rate that CD4051 can meet...
I want to use CD4051 as the RX expansion of USART serial port, but how to calculate what baud rate communication the CD4051 speed can meet?...
chuzhaonan Analogue and Mixed Signal
TI analog temperature sensor lmt88
[i=s]This post was last edited by qwqwqw2088 on 2020-2-20 11:47[/i]TI's, measurement range -55 ~ 130 ℃, wide voltage supply 2.4-5.5V, quiescent current less than 10uA, high precision, analog output.Th...
qwqwqw2088 Analogue and Mixed Signal
A 39-year-old single programmer moves into a nursing home? The happiness of a programmer is beyond your imagination!
[Source: Changsha Evening News] According to @Phoenix Weekly, a nursing home in Chongqing recently welcomed its youngest resident - Mr. Gu, who is only 39 years old. Living in a nursing home at the ag...
eric_wang Talking
Recruiting part-time MCU engineers (Dalian area)
Recruiting 1-2 part-time MCU engineers, familiar with STM32 and RTOS preferred, preferably students of Dalian University of Technology, WeChat/Tel: 13478402712...
reayfei Talking about work
Import HFSS devices into AD to generate PCB files
After designing and simulating the device in HFSS, physical processing is required. Most PCB manufacturers do not accept HFSS files. You can export DXF CAD files to the manufacturers, but if the devic...
btty038 RF/Wirelessly

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号