LME / 60mm
The LME Series indicating light provides the latest in LED
technology
SIZE:
INPUT VOLTAGE
OPTIONS:
FUNCTIONS
AVAILABLE:
60mm diameter
- AC/DC24V
- AC120V
- Continuous only
- Continuous, Flashing, Alarms
MOUNTING OPTIONS:
- Pole mount: with 300mm aluminum pole, plastic circular
bracket
- Direct mount: includes 3 mounting nuts
BODY STYLE:
- Pre-assembled, pre-wired
- Interchangeable and stackable after purchase
BODY COLOR:
TIERS:
MODULE COLORS:
ALARMS (FB STYLE
ONLY):
Beige
1-5 modules can be stacked
Red / Amber / Green / Blue / Clear
- Alarm 1: selectable, single-tone, intermittent (fast beep)
alarm, 85dB (at 1m)
- Alarm 2: selectable, single tone, intermittent (slow beep)
alarm, 85dB (at 1m)
RATINGS:
- CE (24V only)
-
UL
Component Recognition (US)
-
UL Component Recognition (Canada)
- RoHS
1
PROTECTION:
- IP-65 (LME, LME-W)
- IP-54 (LME-FB, LME-FBW)
- Type 4 / 4X / 13 (indoor, direct-mount only)
CONTROL OPTIONS:
- Dry contact closure such as switches or relay contacts
- Open-collector transistor (NPN or PNP for DC24V, NPN for
AC120V)
- Direct voltage control for DC24V, continuous and alarm
functions only
Specifications
Input Voltage
Operating temperature Range
Relative Humidity
Flashing Cycle (“FB” styles only)
Alarm Sound Level (“FB” styles only, measured
from the front direction, characteristic: A)
Alarm Sound Description (“FB” styles only)
Mounting Location Options
Mounting Direction Options
Protection Rating
Vibration
Insulation Resistance
Withstand Voltage (AC/DC24V)
Dielectric Voltage (AC120V)
Luminous Intensity
(mcd = millicandela)
Applicable Standards
CE
UL
RoHS
Red
53
1.3
2.0
Alarm 1
Alarm 2
Options
Rated Voltage
Operating Voltage
LME
AC/DC24V
AC120V
AC/DC24V (50-60 Hz)
AC120V (50-60 Hz)
Rated Voltage + or - 10%
-30
O
C ~ +60
O
C
Less than 90%
60 + or – 12 flashes per minute
Max: 84 + or – 4dB (at 1m)
Min: 64 + or – 4dB (at 1m)
Max: 86 + or – 4dB (at 1m)
Min: 66 + or – 4dB (at 1m)
Intermittent, single-tone; Alarm 1: fast beep, Alarm 2: slow beep
Indoor use only
Upright only
LME, LME-W
IP-65
LME-FB, LME-FBW
IP-54
19.6m/s
2
(30Hz) (2 hours each: front-back, right-left, up-down)
More than 1 Megohm between terminals and chassis at DC500V
AC500V applied between terminals and chassis for 1 minute without breaking insulation
AC1000V applied between terminals and chassis for 1 minute without breaking insulation
Red
Amber
Green
Blue
Clear
350mdc
580mcd
1300mcd
340mcd
1200mcd
EN60958-1: 1993
UL Component Recognition per UL-508 (File No. E215660)
RoHS Directive 2005/95/EC
LED Modules
Amber
Green
53
20
1.3
0.5
2.0
0.8
Alarm 1
Blue
Clear
Steady
Inrush
20
20
40
250
0.5
0.5
1.0
-----
0.8
0.8
1.4
-----
1.7W @ AC120V
Alarm 2
Steady
Inrush
40
250
1.0
-----
1.4
-----
Power Consumption
AC/DC24V
AC120V
Current (mA @ 24V)
Watts
Watts
Standby Power
Contact Capacity (I
S
= current capacity; V
S
= withstand voltage; V
C
= dielectric breakdown voltage; I
L
= leakage current)
LED Light Module
Alarm
Power Supply
LED Light Module (Signal wire)
Alarm (Signal wire)
Power Supply
Leakage Current
Fuse (not included)
Contact Capacity
I
S
>= 100mA; V
S
>= AC35V
I
S
>= 300mA; V
S
>= AC35V
I
S
>= 500mA; V
S
>= AC35V
Contact Capacity
I
S
>= 100mA; V
S
>= AC35V
I
S
>= 300mA; V
S
>= AC35V
I
S
>=150mA; V
S
>= AC125V
I
L
= 0.1mA or less
1A (250V)
Transistor Capacity (NPN and PNP)
I
C
>= 100mA; V
C
>= 35V
I
C
>= 300mA; V
C
>= 35V
Transistor Capacity (NPN)
I
C
>= 100mA; V
C
>= 35V
I
C
>= 300mA; V
C
>= 35V
AC/DC24V
AC120V