MPB125 Single-Output AC-DC Series Data Sheet
Features
•
RoHS lead free and lead-solder-exempt products are
available
• High power density in an industry-standard 3" x 5"
footprint
• Power Factor Correction (PFC) meets EN61000-3-2
• CE marked to Low Voltage Directive (Pending)
• Input transient & ESD compliance to
EN61000-4-2/-3/-4/-5
• MTBF In excess of 1M hours based upon field data
• Output adjustment potentiometer
Description
The MPB125 Series incorporates patented high efficiency circuitry, high power density and active Power Factor
Correction (PFC) to meet the requirements of networking and data communications systems, as well as commercial
and industrial configurations.
MPB125 single-output models deliver a fully-regulated output. The MPB125 is rated for convection as well as forced-
air cooling. Full output power is available with as few as 5 Cubic Feet per Minute (CFM) forced-air cooling.
The MPB125 product line is approved to the latest international regulatory standards and displays the CE Mark.
Single Output Model Selection
MODEL
OUTPUT
VOLTAGE
(VOLTS)
MAXIMUM OUTPUT
CURRENT (AMPS),
130 LFM
TOTAL
REGULATION
%
RIPPLE & NOISE
1
% pk-pk
ADJUSTMENT RANGE
MPB125-1012
2, 3
12V
10.5A
±1%
1%
11.76 to 12.24V
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage- AC
Input Frequency
Brownout Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor Circuitry
Operating Frequency
NOTES:
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
90 VAC at full rated load.
Non-user serviceable internally located AC input line fuse, 3.15A.
Internally limited by thermistor,
110VAC:
one cycle, 25° C.
220VAC:
Active PFC meets requirements of EN61000-3-2.
Switching frequency of main transformer.
90
47
90
17
264
63
1.8
23
46
45
VAC
Hz
VAC
ms
A
RMS
A
PK
kHz
1
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2
Maximum forced-air output power is 125 watts with 5 CFM airflow.
3
Maximum convection output power is 70 watts.
Ordering Information:
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
RoHS lead solder exempt 1
No RoHS suffix character required.
RoHS compliant for all 6 substances
Add “G” as the last character of the part number.
1 The solder exemption refers to all the restricted materials except lead in solder.
MCD10155 Rev. 1.0, 15-Apr-10
Page 1 of 4
www.power-one.com
MPB125 Single-Output AC-DC Series Data Sheet
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Minimum Loads
Ripple and Noise
Output Power (Note 1)
Overshoot /Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
Full Load, 230VAC.
No Minimum Load is Required
Full load, 20 MHz bandwidth.
At 5 CFM forced-air cooling. See Application Note #M3 for details.
Convection:
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes from 85-132 VAC
or 170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Maximum deviation due to a 25% load change with unit at 75% load.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
80
See Model Selection Chart
125
70
10
See Model Selection Chart
3
0.2
0.2
1.5
20
%
Amps
Watts
%
%
Sec
ms
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Overload Protection
Thermal Shutdown
MPB125-1012
Fully protected against output short circuit or overload. Automatic recovery upon
removal of overload condition.
Protected against overtemperature conditions.
Unit recovers when overtemperature condition is removed.
13.5
16.5
VDC
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Flicker
Radiated Susceptibility
EFT/Burst
Input Transient Protection
RF Immunity
Magnetic Fields
Voltage Dips
Insulation Resistance
Leakage Current
UL60950-1.
CSA 22.2 No. 60950-1.
EN60950 (TÜV).
IEC60950-1
AC to chassis.
1500
Input to output.
3000
EN55022 Conducted.
B
Per EN61000-4-2, Level 4
8
Per EN61000-3-3.
Per EN61000-4-3.
Per EN61000-4-4.
1
Per EN61000-4-5, Level 3, 2 kV (Line-to-Gnd) minimum, 1 kV (Line-to-Line) minimum.
Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave)
Per EN61000-4-8.
Per EN61000-4-11.
Input to output.
Per EN60950 (264 VAC)
APPROVED
VAC
VDC
Class
kV
3
V/m
kV
V/m
A/m
M
mA
3
1
10
1.0
MCD10155 Rev. 1.0, 15-Apr-10
Page 2 of 4
www.power-one.com
MPB125 Single-Output AC-DC Series Data Sheet
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating Temperature
Storage Temperature
Forced-Air Cooling
Operating
Non-Operating
Derate linearly from 50 to 70°C to 50% power at 70°C
At 100% load:
0
-40
10K
50K
50
85
ASL Feet
°C
°C
Temperature Coefficient
Relative Humidity
Shock
Vibration
Forced-air cooling of 5 CFM is required for full output power. Air velocity
is measured with power supply mounted on 0.375" (9.5mm) standoffs. Airflow
direction is from the input section to the output section. See Application Note for details.
Included in total regulation of outputs.
Non-Condensing.
5
Operating: 11 ±3ms, 3 axes, Half Sine.
Non-operating: 11 ±3ms, 3 axes, Half Sine.
Operating:
Random vibration, 5-500 Hz, 10 minutes each axis.
Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis.
95
15
40
2.4
6.0
%RH
Gpk
G
RMS
G
RMS
MCD10155 Rev. 1.0, 15-Apr-10
Page 3 of 4
www.power-one.com
MPB125 Single-Output AC-DC Series Data Sheet
Mechanical Drawing (MPB125-1012 Model)
WEIGHT:
J 1 - A C INPUT CONNECTOR
Pin 1
Pin 2
Pin 3
NEUTRAL
N O PIN
LINE
5.00"
(127.0)
4.55"
(115.57)
0.63 lb. (0.3 kg)
OUTPUT VOLTAGE
ADJUSTMENT POTENTIOMETER
Ø 0.16" (4 PL)
(4.06)
J2 -
Pin
Pin
Pin
Pin
Pin
Pin
1
2
3
4
5
6
J 2 - V 1 DC OUTPUT
CONNECTOR
TOP VIEW
PIN #1
MPB125
-1012
+12V
+12V
+12V
RTN
RTN
RTN
3.00" 2.78"
(76.2) (70.6)
2.56"
(65.02)
PIN #1
PIN #1
J4-
CONNECTOR
FASTENER
CLEARANCE
AREA (4 PL)
CAUTION
DO NOT USE CONNECTOR J4. THE J4 CONNECTOR
IS FOR INTERNAL TESTING OF THE POWER SUPPLY BY
POWER-ONE ONLY. PINOUT IS FOR REFERENCE ONLY.
SAFETY GROUND
CONNECTION POINT
SCREWS SHOWN
FOR REFERENCE
ONLY
0.06"
(1.5)
1.25"
(31.75)
1.00"
(25.4)
PRINTED
CIRCUIT
BOARD
SIDE VIEW
0.19"
(4.8)
END VIEW
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125
-1012
09-50-8033
08-52-0113
09-50-8063
08-52-0113
J1
J2
Housing
Pins
Housing
Pins
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
MCD10155 Rev. 1.0, 15-Apr-10
Page 4 of 4
www.power-one.com