HPT DC-DC Series Data Sheet
Triple-Output, 15 Watts
Features
• Triple-output 2” X 2”
• Open-frame packaging
• 2.5 million hours MTBF
• Short-circuit and overvoltage protection
• 500V isolation
• Input undervoltage lockout
• 3-1 wide voltage input
• 100°C baseplate operation
Description
HPT triple output dc-dc converters provide 15 watts of output power in an industry standard package. HPT’s feature
excellent efficiency and industry-leading power density. The HPT has open-frame packaging to provide maximum
useable power with minimal thermal constraints. These units are fully compatible with production board washing
processes.
Technical Specifications
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
48 VDC Wide
Output
Setpoint Accuracy
Auxiliary Setpoint Accuracy
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Ripple and Noise w/ 25 MHz BW, Pk-Pk / RMS
Current Limit Type
Current Limit Threshold Range, % of I
out
Rated
Short Circuit Current Max.
OVP Trip Range
OVP Type
General
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF
†
(Bellcore TR-NWT-000332)
Safety
Weight (approx.)
REV. JUN 04, 2004
200 kHz
500 VDC
500 VDC
500 VDC
0.02 ppm/°C
-40 to +100°C
-40 to +125°C
105 to 115°C
95%
2g
6 hrs
2.5 x 10
Consult Factory
0.85 oz
±1%
5%
±1% V
out
±1% V
out
10 % I
out
Rated
25% I
out
1% V
out
250
µs
1% / 0.3% V
out
Hiccup
110 - 140%
200% I
out
Nom.
110 - 140% V
out
Nom.
Second Control Loop
Notes
1 For negative logic, add suffix “N” to model number.
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
10 - 30 VDC
34 - 75 VDC
20 - 60 VDC
Page 1 of 3
OPTIONS
This page is offered as a reference. Consult factory for actual availability of options. When ordering
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the
model number. Ordering option examples are located below the options table.
OPTION
Negative Logic
Lucent-Compatible Trim
Trim
Enable
Trim and Enable
SUFFIX
N
T
1
2
3
APPLICABLE SERIES
HAS, HBD, HBS, HES, HLS, HLD, LES,
QBS, QES, QLS, TES, TQD
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
IAS, LES
IAD, IAS, LES, SMS
IAS, LES
REMARKS
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Pin Length and Heat Sink Options
0.110" (2.8mm) Pin Length
0.150" (3.8mm) Pin Length
0.24" (6.1mm) Horizontal Heat Sink
0.24" (6.1mm) Vertical Heat Sink
0.45" (11.4mm) Horizontal Heat Sink
0.45" (11.4mm) Vertical Heat Sink
0.95" (24.1mm) Horizontal Heat Sink
0.95" (24.1mm) Vertical Heat Sink
8
9
1H
1V
2H
2V
3H
3V
All Leaded Models
All Leaded Models
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Standard Pin Length is 0.180" (4.6mm)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heat sink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president
of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. JUN 04, 2004