EEWORLDEEWORLDEEWORLD

Part Number

Search

800-010-01ZNU9-19HX

Description
Circular Connector, 19 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size214KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

800-010-01ZNU9-19HX Overview

Circular Connector, 19 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

800-010-01ZNU9-19HX Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH CHROMATE
Shell materialALUMINUM ALLOY
Housing size9
Termination typeCRIMP
Total number of contacts19
Base Number Matches1
A
B
C
In-Line
Rear Panel Jam Nut Mount
Square Flange Mount
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
Series 800
Series 800 “Mighty Mouse”
Original UNF Threaded Coupling
Series 800 Receptacles – Crimp Termination
Integral Band Platform
for direct attachment of a cable
shield using a
BAND-IT®
strap. Install a boot, or overmold
onto the band platform. An accessory thread is available
for attaching strain reliefs and backshells.
Three Shell Options:
Jam nut with o-ring for rear panel
mounting, square flange or in-line receptacle for free-hanging
cables.
HOW TO ORDER
Sample Part Number
80 0- 0 11
Series
-0 1
Shell Style
M
Shell Material /
Finish
C
6-4
Shell Size- Insert
Arrangement
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contacts
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
N
Shell Key
Position
N
Normal
-01
In-Line
800-010
Receptacle with
Banding Platform
-02
Square Flange
for Front or Rear
Mounting
5-3
Aluminum / Black
6-1
Anodize
6-4
M
6-7
Aluminum / Electroless
7-1
Nickel
7-10
NF
8-13
Aluminum / Cadmium
9-4
with Olive Drab
9-19
Chromate
10-26
ZN
12-2
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
12-37
X
Pos. X
P
Pin
Y
Pos. Y
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
Z
Pos. Z
800-011
Receptacle with
Accessory Thread
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
-07
Jam Nut for Rear
Panel Mounting
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
C-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
About posting and replying prestige
Are the rules for posting and replying on mobile and PC different? Following the same rules, it seems that there is no prestige value on the mobile, only point value?...
UUC Talking
[Domestic RISC-V Linux board Fang·Starlight VisionFive trial report] C language programming to control WS2812B colorful lamp beads
The RISC-V single-board computer used in this trial provides us with 40 pin interfaces, including the SPI interface. WhatI want to share today is how to use SPI to drive the ws2812B colorful lamp bead...
HonestQiao Domestic Chip Exchange
The AD voltage check has been completed, how to connect it to the LED
1. Battery voltage detection . 2. Voltage displayed on LCD1602 3. When the voltage is lower than 2.6V, the indicator light flashes. 4. When the voltage is higher than 3.3V, the indicator light flashes...
新晋电子发廋友 51mcu
Mechanical and electrical system testing and control from entry to mastery
"Electromechanical System Testing and Control from Entry to Mastery" is aimed at the professional knowledge background of undergraduate graduates majoring in electromechanical engineering. First, in t...
arui1999 Download Centre
I would like to ask a question about LCD power supply circuit.
The picture shows an LCD power supply circuit. Boosting 5V to 9.6V is a normal boost circuit. I would like to ask about the generation principle of +18V and -7.5V....
Kkk- Power technology
Tektronix TDS7254 Oscilloscope Trigger Failure Repair Case
An example of troubleshooting a trigger failure on a Tektronix TDS7254 oscilloscope1. Instrument model:Tektronix oscilloscope TDS72542. Fault phenomenon:The customer reported that after the oscillosco...
agitek2019 Integrated technical exchanges

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号