RMB962
miniature relays
BISTABLE
2-COILS
1
• Height 15 mm • IP 67
• For PCB
• Insulation 4 kV / 8 mm
• High switching capacity, low power consumption
• Bistable relays with two coils • DC coils
• Terminals raster: type A - 3,2 mm for version 1 C/O,
type A - 5,0 mm for version 1 NO
❶
• Recognitions, certifications, directives: RoHS,
1 C/O, 1 NO
AgSnO
2
, AgCdO, AgCdO/Au 3,5 µm
400 V / 300 V
24 V
AgSnO
2
,
24 V
AgCdO
AgCdO/Au 3,5 µm - contact Relpol S.A.
Contact data
Number and type of contacts
Contact material
Max. switching voltage
Min. switching voltage
Rated load
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
Contact resistance
Max. operating frequency
• at rated load
• no load
AC/DC
AC1
8 A / 250 V AC
100 mA
AgSnO
2
,
100 mA
AgCdO
AgCdO/Au 3,5 µm - contact Relpol S.A.
AC1
10 A
8A
2 000 VA
2,4 W
AgSnO
2
,
2,4 W
AgCdO
AgCdO/Au 3,5 µm - contact Relpol S.A.
≤
100 mΩ
AC1
3 600 cycles/hour
20 000 cycles/hour
3...24 V
❷
see Table 1
min. 10 ms;
Coil data
Rated voltage
Operating range of supply voltage
Duration of supply voltage pulse
DC
max. 5 s
Insulation
Insulation category
Insulation rated voltage
Insulation max. voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
• between coil and contacts
• contact clearance
Contact - coil distance
• clearance
• creepage
C250
250 V AC
400 V AC
4 000 V AC
III
PN-EN 60664-1
3
4 000 V AC
1 000 V AC
≥
8 mm
≥
8 mm
10 ms
7 ms
8 A, 250 V AC
> 10
5
5
> 10
5 A, 250 V AC
7
> 3 x 10
29 x 10 x 15 mm
10 g
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive AC1
• cos
φ
= 0,4
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storage
• operating
Cover protection category
Environmental protection
Vibration resistance
Solder bath temperature
Soldering time
-40...+80
o
C
-40...+70
o
C
IP 67
RTII
PN-EN 116000-3
10 g
10...100 Hz
max. 270
o
C
max. 5 s
The data in bold type pertain to the standard versions of the relays.
Note:
At IP 67 waterproof version it is recommended that the vent pin is removed after soldering and washing process.
❶
Relays with other rasters available - contact Relpol S.A.
❷
Supply of bistable relays
RMB962
- see page 2
Export Sales Department
Phone +48 68 47 90 832 •
Marketing Department
Phone +48 68 47 90 900
www.relpol.com.pl
RMB962
miniature relays
3
Ordering codes
Cover protection
category
Type
Type of raster
Contact
material
Number and type
of contacts
Connection
mode
Coil code
Coil type
2
- bistable, two coils
Type of raster
❶
see Table 1 page 2
A
- 3,2 / 5,0 mm raster
Contact material
10
- AgCdO
12
- AgCdO/Au 3,5 µm
30 - AgSnO
2
Number and type of contacts
11
- 1 C/O
21
- 1 NO
Cover protection category
3
- in cover, IP 67 waterproof version
Connection mode
5
- for PCB
❶
Relays with other
rasters available
- contact Relpol S.A.
Examples of ordering codes:
RMB962A-3011-35-1012
RMB962A-3021-35-1012
bistable relay
RMB962
with two coils, contact material AgSnO
2
, with one changeover
contact - raster type A (3,2 mm), in cover IP 67, for PCB, voltage version 12 V DC
bistable relay
RMB962
with two coils, contact material AgSnO
2
, with one normally open
contact - raster type A (5,0 mm), in cover IP 67,
for PCB
, voltage version 12 V DC
Export Sales Department