Microstructure Pressure Sensors
0 psi to 5 psi through 0 psi to 300 psi
FEATURES
•
Low Cost
•
Small Size
•
Internal Temperature
Compensation
•
Absolute or Gauge
Pressures
•
High-Impedance Bridge
•
Low Power Consumption
TYPICAL APPLICATIONS
•
Pneumatic Controls
•
Automotive Diagnostics
•
Medical Equipment/
Instrumentation
•
Dental Equipment
•
Environmental Controls
•
Barometric Pressure
Measurement
•
Altimeters
•
Pneumatic Controls
•
Battery Powered Equipment
SCC SMT Series
The SCC series sensors offer an extremely low cost sensor element with a
temperature stable output when driven with a constant current source.
These integrated circuit sensors were designed for extremely cost sensitive
applications where precise accuracy over a wide temperature range is not
required.
The SCC series SMT offers a standard surface mount package and is
offered with an optional ported lid to fit in a variety of application. This series
of sensors are designed for measuring absolute and gage pressure ranges
from 0 psi to 5 psi through 0 psi to 300 psi. The absolute devices have an
internal vacuum reference and an output voltage proportional to absolute
pressure. Differential devices allow application of pressure to either side of
the sensing diaphragm and can be used for gauge or differential
measurements.
The SCC series SMT sensors offer a 4-pin closed bridge configuration for
electrical connection with additional pads provided for mechanical support.
Pulsed power is recommended to achieve maximum accuracy and conserve
battery power in portable applications.
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
WARNING
MISUSE OF DOCUMENTATION
•
The information presented in this product sheet is for reference only.
Do not use this document as a product installation guide.
•
Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Sensing and Control
Microstructure Pressure Sensors
0 psi to 5 psi through 0 psi to 300 psi
PRESSURE SENSOR SPECIFICATIONS
(1)
Characteristic
Supply Current, I
S
Compensated Temperature
Operating Temperature
Storage Temperature
Humidity
Lead Temperature (Soldering 2 s to 4 s)
Maximum Ratings
1.5 mA
0 °C to 50 °C [32 °F to 122 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
-55 °C to 125 °C [-67 °F to 257 °F]
0 % to 100 % RH
250 °C [482 °F]
SCC SMT Series
STANDARD PRESSURE RANGES
(1)
Part Number
SCC05GSMT(P)
SCC15(A,G)SMT(P)
SCC30(A,G)SMT(P)
SCC100(A,G)SMT(P)
SCC300ASMT(P)
Operating
Pressure
0 psi to 5 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
0 psi to 300 psi
Maximum
Pressure
20 psi
30 psi
60 psi
150 psi
450 psi
(2)
Operating
Pressure
0 psi to 5 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
0 psi to 300 psi
Sensitivity
Nominal
Std Dev.
7.50
±0.68
4.30
±0.37
2.90
±0.57
1.30
±0.20
0.30
±0.03
(3)
Units
mV/mA/psi
mV/mA/psi
mV/mA/psi
mV/mA/psi
mV/mA/psi
PERFORMANCE SPECIFICATIONS
(1)
Characteristics
Zero Pressure Offset (@ T
A
=25 °C)
(4)
Linearity, Hysteresis, Repeatability
(5)
Temperature Effect on Span
(5)
Temperature Effect on Offset
(6)
Long-Term Stability of Offset and Span
(7)
Response Time (10 % to 90 %)
Input Resistance (@T
A
=25 °C)
Output Impedance
Min
-30.0
-1.0
-1.5
-2.0
–
–
4.00
4.00
Typ
-10.0
0.2
0.25
.5
0.1
0.1
5.00
5.00
Max
20.0
1.0
1.5
2.0
–
–
6.50
6.50
Units
mV
% FSS
% FSS
% FSS
% FSS
ms
kΩ
kΩ
SPECIFICATION NOTES
Note 1:
Note 2:
Note 3:
Reference Conditions: Supply Current, I
S
= 1.0 mA, T
A
= 25 °C to 70 °C [32 °F to 158 °F],
Common-mode Line Pressure = 0 psig, Pressure Applied to P1 unless otherwise noted.
If the maximum pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing
die may fracture.
Sensitivity is the ratio of the output signal voltage change to the corresponding input pressure change. The
sensitivity is characterized by design and periodic production testing. This parameter in not 100 % tested in
production.
Linearity is based on best straight line fit. Hysteresis is the maximum output difference at any point within the
operating pressure range for increasing and decreasing pressure.
Maximum error band of the offset voltage and the error of the band of the span over the compensated
temperature range, relative to the 25 °C reading. Typical temperature coefficients for span and resistance are
-2200
ppm/°C and 2200 ppm/°C respectively. Temperature effects on offset and span are guaranteed by design.
These parameters are not 100 % tested in production.
Long term stability over a one year period.
Response time for 0 psi to full scale span pressure step change.
Note 4:
Note 5:
Note 6:
Note 7:
2 Honeywell
•
Sensing and Control
Microstructure Pressure Sensors
0 psi to 5 psi through 0 psi to 300 psi
DIMENSIONAL DRAWINGS – For Reference Only mm [in]
LOW PROFILE SMT
1,10
O [.05]
3,30
[.13]
3,70
[.14]
O 0,5 [.02]
FOR GAGE PORT (P2)
+ OUT
+ EX
- EX
- OUT
2,00
[.08]
SCC SMT Series
7X 0,76 [.03]
8X 0,76 [.03]
3,80
[.15]
3,30
[.13]
6,60
[.26]
7,60
[.30]
6,60
[.26]
7,60
[.30]
3,30
[.13]
8X 1,27
[.05] ON CENTER
PADS
PORTED “P” SMT
7X
1,01
[.04]
7,61
[.30]
3,3
[.13]
2,3
[.09]
3,3
[.13]
R0,3
[.01]
0,5 [.02]
FOR GAGE PORT (P2)
+ OUT
6,6
[.26] 7,6 + EX
- EX
[.30]
- OUT
8,7
[.34]
2,0
[.08]
3,3
[.13]
0,76
[.03]
8X 0,76
[.03]
R0,3
[.01]
6,6
[.26]
3,8
[.15]
1,27
8X [.05] ON CENTER
PADS
ORDERING INFORMATION
Pressure Range
0 psi to 5 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 100 psi
0 psi to 300 psi
Standard SMT Package
Absolute
Gage
–
SCC05GSMT
SCC15ASMT
SCC15GSMT
SCC30ASMT
SCC30GSMT
SCC100ASMT
SCC100GSMT
SCC300ASMT
SCC3000GSMT
Ported SMT Package
Absolute
Gage
–
SCC05GSMTP
SCC15ASMTP
SCC15GSMTP
SCC30ASMTP
SCC30GSMTP
–
–
–
–
3 Honeywell
•
Sensing and Control
Microstructure Pressure Sensors
0 psi to 5 psi through 0 psi to 300 psi
EQUIVALENT CIRCUITS
Vs
SCC SMT Series
- Out
+Out
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are
returned to Honeywell during the period of coverage,
Honeywell will repair or replace without charge those
items it finds defective.
The foregoing is Buyer’s
sole remedy and is in lieu of all other warranties,
expressed or implied, including those of
merchantability and fitness for a particular
purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and
reliable as of this printing. However, we assume no
responsibility for its use.
While we provide application assistance personally,
through our literature and the Honeywell web site, it
is up to the customer to determine the suitability of
the product in the application.
For application assistance, current specifications, or
name of the nearest Authorized Distributor, contact a
nearby sales office. Or call:
1-800-537-6945 USA/Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com
Sensing and Control
www.honeywell.com/sensing
Honeywell
11 West Spring Street
Freeport, Illinois 61032
008091-1-EN IL50 GLO 1103 Printed in USA
Copyright 2003 Honeywell International Inc. All Rights Reserved.