CENTIGRID
®
SURFACE MOUNT
COMMERCIAL RELAYS
DPDT
SERIES
S114
SERIES
DESIGNATION
S114
S114D
S114DD
DPDT basic relay
RELAY TYPE
DPDT relay with internal diode for coil transient suppression
DPDT relay with internal diodes for coil transient suppression and polarity
reversal protection
INTERNAL CONSTRUCTION
UNI-FRAME
DESCRIPTION
The Series S114 Surface Mount Centigrid
®
Relay is an ultraminiature,
hermetically sealed, armature relay. The low profile height (.360") and .100"
ARMATURE
UPPER
STATIONARY
CONTACT
MOVING
CONTACT
LOWER
STATIONARY
CONTACT
lead spacing make it ideal for applications where extreme packaging density
and/or close PC board spacing are required. The specially formed leads are
pre-tinned to make the relays ideal for most types of surface mount solder
reflow processes.
CENTIGRID
®
AND TO-5
The basic design and internal construction are identical to the Series 114
Centigrid
®
relays, and are capable of meeting Teledyne Relays’ T
2
R
®
requirements. The following unique construction features and manufacturing
techniques provide overall high reliability and excellent resistance to
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
–65°C to +125°C
Temperature Storage
(Ambient)
Operating
–55°C to +85°C
Vibration
(General Note 1)
Shock
(General Note 1)
Acceleration
Enclosure
Weight
Reflow Temperature
30 g’s to 3000 Hz
environmental extremes:
• All welded construction.
• Unique uni-frame design providing high magnetic efficiency and mechanical
rigidity.
75 g’s,
6 msec, half-sine
50 g’s
Hermetically sealed
0.07 oz. (1.9g) max.
260°C max. temp.
1 min. max.
• High force/mass ratios for resistance to shock and vibration.
• Advanced cleaning techniques provide maximum assurance of internal
cleanliness.
• Precious metal alloy contact material with gold plating assures excellent
high current and dry circuit switching capabilities.
©2003 TELEDYNE RELAYS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
S114 Page
1
S114/1203/Q1
SERIES S114
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
Contact Arrangement
Rated Duty
Contact Resistance
Contact Load Ratings (DC)
(See Fig. 3 for other DC
resistive voltage/current ratings)
Contact Load Ratings (AC)
Contact Life Ratings
Contact Overload Rating
Contact Carry Rating
Coil Operating Power
Operate Time
Release Time
Contact Bounce
Intercontact Capacitance
Insulation Resistance
Dielectric Strength
Negative Coil Transient (Vdc)
Diode P.I.V. (Vdc)
2 Form C (DPDT)
Continuous
0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header along lead)
Resistive:
Inductive:
Lamp:
Low Level:
Resistive:
1 Amp/28Vdc
200 mA/28Vdc (320 mH)
100 mA/28Vdc
10 to 50 μA/10 to 50mV
250 mA/115Vac, 60 and 400 Hz (Case undergrounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
2A/28Vdc Resistive (100 cycles min.)
Contact factory
450 milliwatts typical at nominal rated voltage at 25°C
2.0 msec max. at nominal rated coil voltage
S114 Series: 1.5 msec max. S114D, S114DD Series: 4.0 msec max.
1.5 msec max.
0.4 pf typical
10,000 megohms min. between mutually isolated terminals
Atmospheric pressure: 500 Vrms/60Hz
70,000 ft.: 125 Vrms/60Hz
S114D, S114DD
1.0 max
S114D, S114DD
100 min.
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
BASE PART
NUMBERS
(See Note 10 for full P/N example)
Coil Voltage (Vdc)
Coil Resistance
(Ohms ±10% @25°C)
Coil Current (mAdc @25°C)
(S114DD Series only)
Pick-up Voltage (Vdc, Max.)
Nom.
Max.
S114, 114D
S114DD (Note 4)
Min.
(Note 5)
Max.
S114, S114D
S114DD
Min.
S114, 114D
Max.
Min.
S114DD
Max.
S114-5
S114-6
S114-9
S114-12
S114-18
S114-26
S114D-5
S114D-6
S114D-9 S114D-12 S114D-18 S114D-26
S114DD-5 S114DD-6 S114DD-9 S114DD-12 S114DD-18 S114DD-26
5.0
5.8
50
39
93.2
128.2
3.5
4.0
0.14
2.3
0.6
2.8
6.0
8.0
98
78
57.8
74.8
4.5
5.0
0.18
3.2
0.7
3.4
9.0
12.0
220
220
33.0
42.9
6.8
7.8
0.35
4.9
0.8
5.3
12.0
16.0
390
390
25.6
32.8
9.0
10.0
0.41
6.5
0.9
6.5
18.0
24.0
880
880
17.5
22.1
13.5
14.5
0.59
10.0
1.1
10.0
26.5
32.0
1560
1560
14.8
18.5
18.0
19.0
0.89
13.0
1.4
13.0
Drop-out Voltage (Vdc)
CENTIGRID
®
AND TO-5
TYPICAL DC CONTACT RATING (RESISTIVE) (Note 2)
300
LOAD VOLTAGE (VDC)
250
200
150
100
50
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
LOAD CURRENT (AMPS DC)
FIGURE 1
S114 Page
2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2003 TELEDYNE RELAYS
S114/1203/Q1
SERIES S114
OUTLINE DIMENSIONS AND RECOMMENDED PAD LAYOUT (Notes 7, 8 & 9)
.335 MAX
(8.51)
TERMINAL LOCATIONS
& SCHEMATIC DIAGRAMS
7
8
1
.275 MAX
(6.99)
.360 MAX
(9.14)
6
2
.378 +.030 TYP
–.020
+.76
9.60 –.51
(
)
Ø.017 REF
(.43)
S114
2° ±2° TYP
5
7
4
3
8 (±) 1
.031 REF (.79)
.035 REF
(.89)
4° MAX TYP
4° MAX TYP
.045 MIN 8 PL
(1.14)
.100 TYP (2.54)
.375 SQ MAX
(9.53)
.200
(5.08)
.410 MIN
(10.41)
.100 4 PL
(2.54)
6
2
S114D
5
7
4 (+) 3
8 (±) 1
.200
(5.08)
(Note 6)
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
.200
(5.08)
6
2
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 msec or transfer in excess of
1 msec.
2. “Typical” characteristics are based on available data and are best estimates. No on-going
verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. For reference only. Coil resistance not directly measurable at relay terminals due to
internal series diode.
5. Measured at nominal voltage for 5 sec. max.
6. Position of leads as they emerge from relay base.
7. Leads will fit noted pad layout with no overhang.
8. Lead ends are coplanar within .008" wide tolerance zone.
9. Terminals coated with SN60 or SN63 solder per QQ-S-571. Kovar exposed at sheared
end of leads.
10.
5
4 (+) 3
S114DD
SCHEMATICS ARE VIEWED
FROM TERMINALS
CENTIGRID
®
AND TO-5
Teledyne Part Numbering System for Surface Mount Relays
S
SURFACE
MOUNT
114
D - 26
SERIES NO.
D = SUPPRESSION DIODE
DD = SUPPRESSION AND POLARITY PROTECTION DIODES
COIL VOLTAGE
11. Add "/R" to end of part number for RoHS compliant solder coated pins (Sn99.3/Cu0.7).
©2003 TELEDYNE RELAYS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
S114 Page
3
S114/1203/Q1
Appendix A: Spacer Pads
Pad designation and
bottom view dimensions
Ø.150
[3.81]
(REF)
Height
For use with the following:
ER411T
ER412, ER412D, ER412DD
712, 712D, 712TN,
RF300, RF310, RF320
ER420, ER422D, ER420DD, 421,
ER421D, ER421DD, ER422, ER422D,
ER422DD, 722, 722D, RF341
ER431T, ER432T,
ER432, ER432D, ER432DD
732, 732D, 732TN, RF303, RF313,
RF323
RF312
ER411, ER411D, ER411DD
Dim. H
Max.
.295 (7.49)
.300 (7.62)
.305 (7.75)
.400 (10.16)
.410 (10.41)
.350 (8.89)
.295 (7.49)
.400 (10.16)
.300 (7.62)
.410 (10.41)
.305 (7.75)
.300 (7.62)
Dim
H
MAX
“M4” Pad for TO-5
Dim
H
MAX
ER431, ER431D, ER431DD
RF311
“M4” Pad for TO-5
RF331
172, 172D
Dim
H
MAX
ER114, ER114D, ER114DD,
J114, J114D, J114DD
ER134, ER134D, ER134DD,
J134, J134D, J134DD
RF100
.400 (10.16)
.315 (8.00)
.420 (10.67)
.320 (8.13)
.300 (7.62)
.400 (10.16)
.325 (8.25)
.305 (7.75)
“M4” Pad for Centigrid
®
.156
[3.96]
(REF)
RF103
122C, A152
Dim
H
MAX
ER116C, J116C
ER136C, J136C
RF180
.256
[6.5]
(REF)
“M9” Pad for Centigrid
®
A150
Notes:
1. Spacer pad material: Polyester ¿lm.
2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering
example in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci¿ed, tolerance is ± .010 (.25).
5. Add 10 m to the contact resistance show in the datasheet.
6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
© 2008 Teledyne Relays
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Appendix A: Spreader Pads
Pad designation and
bottom view dimensions
.370 [9.4]
MAX SQ
.100
[2.54]
Height
For use with the following:
ER411T, J411T, ER412, ER412D
ER412DD, J412, J412D, J412DD
ER412T, J412T
712, 712D, 712TN
ER431T, J431T, ER432, ER432D
ER432DD, J432, J432D, J432DD
ER432T, J432T
732, 732D, 732TN
ER420, J420, ER420D, J420D
ER420DD, J420DD, ER421, J421
ER421D, J421D, ER421DD
J422D, ER422DD, J422DD, 722
ER411T
ER412, ER412D, ER412DD
J412, J412D, J412DD
Dim. H
Max.
.388 (9.86)
.393 (9.99)
.493 (12.52)
.503 (12.78)
.398 (10.11)
Dim
H
MAX
.150
[3.81]
.014
[0.36]
(REF)
.300
[7.62]
.100
[2.54]
.200
[5.08]
.370
[9.4]
MIN
“M” Pad 5/ 6/
.390 [9.91]
SQ
.100
[2.54]
.441 (11.20)
.451 (11.46)
.451 (11.46)
.546 (13.87)
.556 (14.12)
.100
[2.54]
.150
[3.81]
.300
[7.62]
Dim
H
MAX
.300
[7.62]
.150
[3.81]
.130
[3.3]
712, 712D
ER421, ER421D, ER421DD
722, 732D
ER431T
ER432, ER432D, ER432DD
732, 732D
ER411, ER411D, ER411DD
ER411TX
ER412X, ER412DX, ER412DDX
ER412TX
712X, 712DX, 712TNX
ER420X, ER420DX, ER420DDX
ER421X, ER421DX, ER421DDX
ER422X, ER422DX
ER422DDX, 722X, 722DDX
ER431, ER431D, ER431DD
ER431TX
ER432X, ER432DX, ER432DDX
ER432TX
732X, 732DX, 732TNX
“M2” Pad 7/ 8/
.370 [9.4]
MAX SQ
.100
[2.54]
.388 (9.86)
.393 (9.99)
.398 (10.11)
Dim
H
MAX
.150
[3.81]
.300
[7.62]
.100
[2.54]
.014
[0.36]
(REF)
.200
[5.08]
.370
[9.4]
MIN
.493 (12.52)
.503 (12.78)
“M3” Pad 5/ 6/ 9/
Notes:
1. Spreader pad material: Diallyl Phthalate.
2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example
in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci¿ed, tolerance is ± .010” (0.25).
5/. Add 25 m to the contact resistance shown in the datasheet.
6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
7/. Add 50 m to the contact resistance shown in the datasheet.
8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet.
9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.)
(800) 284-7007 • www.teledynerelays.com
+44 (0) 1236 453124 • www.teledyne-europe.com
© 2008 Teledyne Relays