EEWORLDEEWORLDEEWORLD

Part Number

Search

MB5904D-4P-POE-DB

Description
INDUSTRIAL 4-PORT MODBUS GATEWAY
CategoryModule/solution   
File Size538KB,4 Pages
ManufacturerATOP Technologies
Download Datasheet Parametric Compare View All

MB5904D-4P-POE-DB Overview

INDUSTRIAL 4-PORT MODBUS GATEWAY

MB5904D-4P-POE-DB Parametric

Parameter NameAttribute value
Functiongateway
modulation or protocol-
frequency-
applicationUniversal
interfaceRS-232/422/485
Sensitivity-
Power - output-
Data rate (maximum)921kbps
MB5904D Series
4-Port Advanced Industrial Secure
Modbus TCP/RTU/ASCII Gateway
FEATURE HIGHLIGHTS
 Industrial EMC
protection, wide temperature operation, -40°C~85°C
 2 Fast-Ethernet ports or 100/1000 SFP slots
 4 Software-selectable RS-232/RS-485/RS-422 serial ports, up to 921kbps
 Bi-Directional Modbus TCP/RTU/ASCII conversion from Serial to Ethernet
and viceversa, VirtualCOM support, advanced Modbus Options available
 Isolated Redundant 12~48 VDC Power Inputs or powered (PoE models)
through through the Ethernet cable (802.3af)
 Embedded security with IPsec VPN
 Configuration via Web Browser/ Serial Console/ Telnet Console/ Utility
 Rugged metal case with wall or DIN-Rail mount
PRODUCT DESCRIPTION
Diverse Hardware Infrastructure
Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of-
use configuration utility provided with Modbus Gateway can quickly select the hardware interface , and easily switch to the existing
communication infrastructure. Industrial EMC protection and wide temperature operation capability make MB5904D ready for every
mission. And if cabling is an issue, the PoE-powered version can allow MB5904D to be powered through PoE.
Advanced embedded security
MB5904D embeds IPsec VPN Encryption, that allows you to tunnel your data securely throught the internet and prevent unauthorized
control of your Serial Devices by malicious people.
Switching between Modbus Protocols
Modbus Gateway supports the standard Modbus protocol
and is capable of converting any Modbus protocols
between Modbus TCP, Modbus RTU, and Modbus ASCII
for all supported hardware interfaces. All of this, in bi-
directional mode: Ethernet and Serial ends can selected to
be either master or slave
Modbus ID Routing
Modbus Gateway supports various types of hardware
communication interfaces, Modbus protocol conversion,
and Modbus ID routing. Therefore the Modbus Gateway
can integrate your existing and complex Modbus
hardware configuration into a simple network that can be
easily managed.
TEL :
+ 886 - 3 - 5508137
FAX:
+ 886 - 3 - 5508131
EMAIL:
sales@atop.com.tw
WEB:
http://www.atop.com.tw
v:
0.5

MB5904D-4P-POE-DB Related Products

MB5904D-4P-POE-DB MB5904D-4P-SIS MB5904D-4P-POE-SIS MB5904D-4P-G-SIS-SFP MB5904D-4P-DB MB5904D-4P-TB MB5904D-4P-POE-TB MB5904D-4P-G-DB-SFP MB5904D-4P-G-TB-SFP
Description INDUSTRIAL 4-PORT MODBUS GATEWAY INDUSTRIAL 4-PORT MODBUS GATEWAY INDUSTRIAL 4-PORT MODBUS GATEWAY INDUSTRIAL 4-PORT MODBUS GATEWAY INDUSTRIAL 4-PORT MODBUS GATEWAY INDUSTRIAL 4-PORT MODBUS GATEWAY INDUSTRIAL 4-PORT MODBUS GATEWAY INDUSTRIAL 4-PORT MODBUS GATEWAY INDUSTRIAL 4-PORT MODBUS GATEWAY
Function gateway gateway gateway gateway gateway gateway gateway gateway gateway
application Universal Universal Universal Universal Universal Universal Universal Universal Universal
interface RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485
Data rate (maximum) 921kbps 921kbps 921kbps 921kbps 921kbps 921kbps 921kbps 921kbps 921kbps
Live broadcast at 10 am today [In-depth study of TI's industrial processor chip AM57X with machine learning accelerator]
AM57X is suitable for high-performance scenarios and is TI's first processor chip with a machine learning accelerator for the industrial field. This seminar will discuss the key features of AM57X and ...
EEWORLD社区 TI Technology Forum
Protecting Your IP Cores - Part 1 Soft IP, Section 1: Encryption of HDL Code
Protecting Your IP Cores - Part 1 Soft IP, Section 1: Encryption of HDL CodeIEEE Std 1735 2014 IEEE Recommended Practice for Encryption and Management of IP HDL Source Code ProtectionIEEE Std 1735 201...
modemdesign Integrated technical exchanges
EEWorld 2020 annual summary: useful articles, popular reviews, download top list, and well-received courses, all here!
EEWorld 2020 annual summary: useful articles, popular reviews, download top list, and well-received courses are here!Useful articles"Switching Power Supply Learning Task Post" Author: maychang https:/...
okhxyyo Talking
Hey guys, this is my first time using Cadence's Pspice simulation and I encountered this problem
Schematic diagram, the components in the library are all drawn by me, so will it be impossible to simulate? How can I solve this problem?...
试图成为理工男的文科生 PCB Design
Industrial Control Electronics Popular Data Download Collection
Signals and Systems (Second Edition) Oppenheim https://download.eeworld.com.cn/detail/lcofjp/572880Control System Design Guide https://download.eeworld.com.cn/detail/zhangxu_seu/606616Modern Control T...
arui1999 Download Centre
How to use Bluetooth 4.2 to implement the Internet of Things
In many wireless IoT devices, such as wearable electronics and battery-powered or self-powered sensors, it is critical to keep power consumption to a minimum. Some of the most important applications f...
fish001 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号