Technical Data Sheet for
LCC12-8
Single-Stage Thermoelectric Module
NOMINAL PERFORMANCE IN NITROGEN
Hot Side Temperature (°C)
Δ Tmax (°C):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
27
66
71
7.4
14.7
1.6
50
74
78
7.4
16.4
---
PRODUCT FEATURES
•
•
•
•
•
•
•
•
•
•
RoHS EU Compliant
Rated operating temperature of 130°C.
Ceramic Material: Aluminum Oxide
Designed for temperature cycling applications.
Porchless configuration for reduced footprint.
Superior nickel diffusion barriers on elements.
High strength for rugged environment.
RTV sealing
option
available.
Lapped option available for multiple module applications.
ACR Matched Set using Alphanumeric code available (see
page 3).
ORDERING OPTIONS
Model Number
LCC12-8-01
LCC12-8-01L
LCC12-8-01S
LCC12-8-01LS
LCC12-8-16LS
Description
Leadwires
Leadwires, Lapped
Leadwires, Sealed
Leadwires, Lapped, Sealed
Leadwires, Lapped, Sealed,
ACR
Matched set of 6
OPERATION CAUTIONS
For maximum reliability, storage and operation below
130°C in a non-condensing
environment is recommended.
To minimize thermal stress, use linear/proportional
temperature control or a
similar method rather than an
ON/OFF method.
INSTALLATION
Recommended mounting methods: Clamp with uniform
pressure to a flat surface with thermal interface material. For
additional information, please refer to our TEC Installation
Guide.
II-VI
Marlow
–
Dallas, TX USA
214-340-4900
877-627-5691
marlow.sales@ii-vi.com
Marlow Industries Europe
GmbH
-
Germany
+49 (0) 6150 5439 - 403
info@marlow-europe.eu
II-VI Japan Inc.
81 43 297 2693 (tel)
center@ii-vi.co.jp
www.ii-vi.co.jp
II-VI
Singapore Pte., Ltd.
(65) 6481 8215 (tel)
info@ii-vi.com.sg
Marlow Industries China, II-VI
Technologies Beijing
86-10-643 98226
info@iivibj.com
MI Form 005-0688 Rev. 4
www.marlow.com
DOC # 102-0412 REV G - PAGE 1 OF 3
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN
TYPICAL PERFORMANCE CURVES
Hot Side Temperature 27°C
80.0
HEAT
LOAD
(WATTS)
0.00
5.00
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
70.0
80.0
Hot Side Temperature 50°C
HEAT
LOAD
(WATTS)
0.00
5.00
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
60.0
T (C)
60.0
T (C)
VOLTAGE (VDC)
40.0
40.0
20.0
20.0
0.0
16.0
VOLTAGE (VDC)
0.0
16.0
12.0
8.0
4.0
0.0
0.0
12.0
8.0
4.0
0.0
0.0
Q=0
T=0
Q=0
T=0
2.0
4.0
6.0
8.0
10.0
2.0
4.0
6.0
8.0
10.0
CURRENT (AMPS)
CURRENT (AMPS)
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at 877-627-5691.
MECHANICAL CHARACTERISTICS
For customer support or general questions please contact a local office or visit our website at
www.marlow.com.
MI Form 005-0688 Rev. 4
All dimensions are in millimeters unless otherwise stated.
www.marlow.com
DOC # 102-0412 REV G - PAGE 2 OF 3