EEWORLDEEWORLDEEWORLD

Part Number

Search

SE5904D-4P-POE-DB

Description
ETHERNET TO SER RS-232/422/485
CategoryModule/solution   
File Size4MB,2 Pages
ManufacturerATOP Technologies
Download Datasheet Parametric Compare View All

SE5904D-4P-POE-DB Overview

ETHERNET TO SER RS-232/422/485

SE5904D-4P-POE-DB Parametric

Parameter NameAttribute value
typeEthernet to serial port
interfaceRS-232/422/485
Number of ports4
Package Check List
Industrial Modbus Gateway x 1 or
Industrial Modbus Concentrator x 1 or
Industrial Protocol Gateway x 1
Installation Overview
The device’s appearance is as in the figure below.
1. If you have purchased the wall mount kit,
proceed to place the screws on the back of
the device as shown in (Fig. 1)
2. Although internal grounding has been
done inside, in order to ensure overall
maximum performance and protect your
device it is still strongly advised to ground
the device properly; hazardous ESD can
come into contact with it and damage your
equipment. On the power terminal block,
there is a terminal for Frame Ground, you
can choose whether to connect it to the
grounding or you may opt to connect to the
grounding screw next to the terminal block
(the one chosen should be connected at all
times) (Fig. 2).
(Fig. 1)
■ The opening to the sides are for the
device’s heat dissipation please never
obstruct or cover them with any objects or
try to insert them through it.
■ This factory IP by default is
10.0.50.100 you can access the device by
its WebUI once it is connected to a
physical network (or using Management
Utility, for more information on Management
Utility, please refer to its manual).
Please be aware that the PC needed for
this procedure needs to be in the same
subnet, or you may refer yourself to the
device User’s Manual.
console
.
V1–
V1+
Relay
Inside the package you will find the following items:
Industrial Serial Device Server x 1 or
Industrial Serial Device Server
Industrial Modbus Gateway
Industrial Modbus Concentrator
Industrial Protocol Gateway
SE5904D/MB5904D/PG5904D Series
7-Pin 5.08mm Lockable Terminal Block (Already mounted to the device) x 1
5-Pin 3.81mm Lockable Terminal Block x 4 (For TB Models)
DIN-Rail Kit (Already mounted to the device) x 1
Protective caps for all SFP and PoE ports (Depend on purchased model)
Installation Guide with Warranty Card x 1
Never install or work on electrical or cabling during periods of lighting activity.
Never connect or disconnect power when hazardous gases are present.
Warning: Hot Surface Do Not Touch.
Caution: CLASS 1 LASER PRODUCT. Do not stare into the laser!
This equipment should be installed indoor and not connect directly with
equipment installed outdoor and use in ordinary industrial location.
USB
V2–
V2+
!
LED Indicators
Name
P1
console
V1–
V1+
Relay
Indoor
Color
Status
On
Off
Message
Power is being supplied through this power input
Power is not supplied through this power input
Version 1.1
Updated in March 2016
Product Layout
Front View
RJ45 DB9 Type
1
2
5
3 4
1
2
3
4
RJ45 TB5 Type
8
7
1
2
5
9
3 4
1
2
3
4
SFP DB9 Type
8
7
1
2
6
3 4
1
2
3
4
SFP TB5 Type
1
8
7
2
6
3 4
1
2
3
4
3. You can then choose whether to plug in the
I/O ports at this point or do it later depending
8
7
USB
P2
Green
V2–
V2+
!
on the actual location of the device or level of
comfort
for
performing
such
operation.
Remember to plug in the protective caps
for the unused SFP and PoE ports.
RUN
Green
Blinking AP firmware is running normally
On/Off System is not ready or halt
On
Off
On
Off
Alarm is triggered by user defined events
Alarm is not triggered by user defined events
Power is being supplied to a Powered Device(PD)
Power is not supplied to a PD
SFP port is connected
9
10
10
11
12
5
4
3
2
1
5
4
3
2
1
11
5
4
3
2
1
12
5
4
3
2
1
5
4
3
2
1
(Fig. 2)
ALM
Red
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
1
PoE
4. Once the plate has been firmly
Green
1. Reset Button 6. SFP Ports LED 9. 10/100 BASE-T(X) Ports or 10/100/1000 BASE-T(X) Ports
2. PWR1 LED
3. PWR2 LED
4. RUN LED
5. PoE LED
7. Alarm LED
and/or 10/100/1000 BASE-T(X) PoE Port
put in place, proceed to mount the
whole device as shown in (Fig. 3)
Proceed to (Fig. 4) if you want to
remo ve the device from DIN-Rail.
(Fig. 3)
On
SFP
Green
Blinking Data is transmitting on this port
Off
SFP port is disconnected
8.COM Ports LED 10. 100/1000 BASE-X SFP Slots
11. 9-Pin Male D-Sub Connector for RS-232/422/485
12. 5-Pin 3.81mm Terminal Block for RS-232/422/485
Top View
1. Grounding Screw
1
2
1
5. Next we can then proceed to
connect the device to the LAN
(switch or PC, depending on the
case), take care on using the
RJ-45 connector; after this we can
then proceed to the device’s
settings.
LAN
(10/100
Mbps
models)
Amber Blinking Data is transmitting at 10Mbps
Green
Blinking Data is transmitting at 100Mbps
Off
On
Ethernet is disconnected
Ethernet is connected at 10/100Mbps
Ethernet is disconnected
Ethernet is connected at 1000Mbps
Ethernet is disconnected
2. Console
3. Type A USB for storage or Wifi
console
V1–
2
4
V1+
Relay
LAN
Amber
Blinking Data is transmitting at 10/100Mbps
Off
On
Off
3
USB
5
6
7
4. Frame Ground
5. Terminal for Power1
6. Relay Output with current carrying capacity
of 1A@30 VDC (Normal Open)
7. Terminal for Power2
(10/100/
1000Mbps
models) Green
Blinking Data is transmitting at 1000Mbps
V2–
V2+
!
P/N:89900489G
(Fig. 4)
2
COM
Green
Blinking COM port is transmitting data
Off
COM port is not transmitting data

SE5904D-4P-POE-DB Related Products

SE5904D-4P-POE-DB SE5904D-4P-POE-SIS SE5904D-4P-G-SIS-SFP SE5904D-4P-DB SE5904D-4P-TB SE5904D-4P-POE-TB SE5904D-4P-G-DB-SFP SE5904D-4P-G-TB-SFP SE5904D-4P-SIS
Description ETHERNET TO SER RS-232/422/485 ETHERNET TO SER RS-232/422/485 ETHERNET TO SER RS-232/422/485 ETHERNET TO SER RS-232/422/485 ETHERNET TO SER RS-232/422/485 ETHERNET TO SER RS-232/422/485 ETHERNET TO SER RS-232/422/485 ETHERNET TO SER RS-232/422/485 ETHERNET TO SER RS-232/422/485
type Ethernet to serial port Ethernet to serial port Ethernet to serial port Ethernet to serial port Ethernet to serial port Ethernet to serial port Ethernet to serial port Ethernet to serial port Ethernet to serial port
interface RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485
Number of ports 4 4 4 4 4 4 4 4 4
C2000 F2810 The program does not run after encrypting the CSM function
My board is C2000 F2810. When the encryption function is not used, I can debug/run the program in debug/release mode. At least I can see the SCI serial port communication data.However, after adding th...
collean Microcontroller MCU
Usage of DSP C54X ioport
How to access I/O and data space in DSP Accessing I/O SpaceI/O space address declaration To access the io space address in the program, you must first define the address to be accessed using the keywo...
fish001 DSP and ARM Processors
My opinion on 3G network
In recent years, the debate about 3G has been endless. Most manufacturers have been ready to go, and lobbyists have shown their talents, but the government has not moved. Some say it is to wait for TD...
234 RF/Wirelessly
McBSP Serial Interface Technology and Program Design of TMS320VC5410
1. DSP serial interface technology   DSP is a unique microprocessor that processes large amounts of information using digital signals. Its working principle is to receive analog signals and convert th...
Aguilera DSP and ARM Processors
Is this the intention of the forum?
I found a situation like this, as shown in the picture below. Is this intentional?...
tiankai001 Suggestions & Announcements
4G DTU
4G DTU is a transmission device that can send data collected by RS232/485 to the cloud server through 3G/4G for data interaction. It can realize wireless long-distance data transmission of serial port...
wzzlin123 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号