Package Check List
■
Industrial Modbus Gateway x 1 or
■
Industrial Modbus Concentrator x 1 or
■
Industrial Protocol Gateway x 1
Installation Overview
The device’s appearance is as in the figure below.
1. If you have purchased the wall mount kit,
proceed to place the screws on the back of
the device as shown in (Fig. 1)
2. Although internal grounding has been
done inside, in order to ensure overall
maximum performance and protect your
device it is still strongly advised to ground
the device properly; hazardous ESD can
come into contact with it and damage your
equipment. On the power terminal block,
there is a terminal for Frame Ground, you
can choose whether to connect it to the
grounding or you may opt to connect to the
grounding screw next to the terminal block
(the one chosen should be connected at all
times) (Fig. 2).
(Fig. 1)
■ The opening to the sides are for the
device’s heat dissipation please never
obstruct or cover them with any objects or
try to insert them through it.
■ This factory IP by default is
10.0.50.100 you can access the device by
its WebUI once it is connected to a
physical network (or using Management
Utility, for more information on Management
Utility, please refer to its manual).
Please be aware that the PC needed for
this procedure needs to be in the same
subnet, or you may refer yourself to the
device User’s Manual.
console
.
V1–
V1+
Relay
Inside the package you will find the following items:
■
Industrial Serial Device Server x 1 or
Industrial Serial Device Server
Industrial Modbus Gateway
Industrial Modbus Concentrator
Industrial Protocol Gateway
SE5904D/MB5904D/PG5904D Series
■
7-Pin 5.08mm Lockable Terminal Block (Already mounted to the device) x 1
■
5-Pin 3.81mm Lockable Terminal Block x 4 (For TB Models)
■
DIN-Rail Kit (Already mounted to the device) x 1
■
Protective caps for all SFP and PoE ports (Depend on purchased model)
■
Installation Guide with Warranty Card x 1
Never install or work on electrical or cabling during periods of lighting activity.
Never connect or disconnect power when hazardous gases are present.
Warning: Hot Surface Do Not Touch.
Caution: CLASS 1 LASER PRODUCT. Do not stare into the laser!
This equipment should be installed indoor and not connect directly with
equipment installed outdoor and use in ordinary industrial location.
USB
V2–
V2+
!
LED Indicators
Name
P1
console
V1–
V1+
Relay
Indoor
Color
Status
On
Off
Message
Power is being supplied through this power input
Power is not supplied through this power input
Version 1.1
Updated in March 2016
Product Layout
Front View
RJ45 DB9 Type
1
2
5
3 4
1
2
3
4
RJ45 TB5 Type
8
7
1
2
5
9
3 4
1
2
3
4
SFP DB9 Type
8
7
1
2
6
3 4
1
2
3
4
SFP TB5 Type
1
8
7
2
6
3 4
1
2
3
4
3. You can then choose whether to plug in the
I/O ports at this point or do it later depending
8
7
USB
P2
Green
V2–
V2+
!
on the actual location of the device or level of
comfort
for
performing
such
operation.
Remember to plug in the protective caps
for the unused SFP and PoE ports.
RUN
Green
Blinking AP firmware is running normally
On/Off System is not ready or halt
On
Off
On
Off
Alarm is triggered by user defined events
Alarm is not triggered by user defined events
Power is being supplied to a Powered Device(PD)
Power is not supplied to a PD
SFP port is connected
9
10
10
11
12
5
4
3
2
1
5
4
3
2
1
11
5
4
3
2
1
12
5
4
3
2
1
5
4
3
2
1
(Fig. 2)
ALM
Red
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
1
PoE
4. Once the plate has been firmly
Green
1. Reset Button 6. SFP Ports LED 9. 10/100 BASE-T(X) Ports or 10/100/1000 BASE-T(X) Ports
2. PWR1 LED
3. PWR2 LED
4. RUN LED
5. PoE LED
7. Alarm LED
and/or 10/100/1000 BASE-T(X) PoE Port
put in place, proceed to mount the
whole device as shown in (Fig. 3)
Proceed to (Fig. 4) if you want to
remo ve the device from DIN-Rail.
(Fig. 3)
On
SFP
Green
Blinking Data is transmitting on this port
Off
SFP port is disconnected
8.COM Ports LED 10. 100/1000 BASE-X SFP Slots
11. 9-Pin Male D-Sub Connector for RS-232/422/485
12. 5-Pin 3.81mm Terminal Block for RS-232/422/485
Top View
1. Grounding Screw
1
2
1
5. Next we can then proceed to
connect the device to the LAN
(switch or PC, depending on the
case), take care on using the
RJ-45 connector; after this we can
then proceed to the device’s
settings.
LAN
(10/100
Mbps
models)
Amber Blinking Data is transmitting at 10Mbps
Green
Blinking Data is transmitting at 100Mbps
Off
On
Ethernet is disconnected
Ethernet is connected at 10/100Mbps
Ethernet is disconnected
Ethernet is connected at 1000Mbps
Ethernet is disconnected
2. Console
3. Type A USB for storage or Wifi
console
V1–
2
4
V1+
Relay
LAN
Amber
Blinking Data is transmitting at 10/100Mbps
Off
On
Off
3
USB
5
6
7
4. Frame Ground
5. Terminal for Power1
6. Relay Output with current carrying capacity
of 1A@30 VDC (Normal Open)
7. Terminal for Power2
(10/100/
1000Mbps
models) Green
Blinking Data is transmitting at 1000Mbps
V2–
V2+
!
P/N:89900489G
(Fig. 4)
2
COM
Green
Blinking COM port is transmitting data
Off
COM port is not transmitting data
Pin Assignments and Connections
9-Pin Male D-sub Connector for RS-232/422/485
Pin
1
2
12345
3
4
5
6789
6
7
8
9
5-Pin Terminal Block for RS-232/422/485
Pin
1 2 3 4 5
1
2
3
4
1 2 3 4 5
5
RS-232
RxD
CTS
TxD
RTS
SG
RS-422 / 4-W RS-485
TxD+
TxD-
RxD+
RxD-
SG
2-W RS-485
Data+
Data-
-
-
SG
RS-232
DCD
RxD
TxD
DTR
SG
DSR
RTS
CTS
RI
RS-422
-
TxD+
RxD+
-
SG
-
RxD-
TxD-
-
RS-485
-
Data+
-
-
SG
-
-
Data-
-
Tx
Rx
Cable Wiring
Rx
Tx
100/1000 Base-X Fiber Optics SFP Slot
SFP Slot
SFP LC Connector Port Connection for Single-mode & Multi-mode modules
Environmental Limits
■ Operating Temperature: -40 to 85°C (-40 to 185°F)
■ Storage Temperature: -40 to 85°C (-40 to 185°F)
■ Ambient Relative Humidity: 5 to 95%, 55°C (non-condensing)
■ Altitude: up to 2,000 m
Warranty Policy
Warranty Conditions
Products supplied by Atop Technologies are covered in this warranty for sub-standard
performance or defective workmanship. The warranty is not, however, extended to
goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock,earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts
Mechanical Dimensions (Unit=mm)
Front View
RJ45 DB9 Type
RJ45 TB5 Type
SFP DB9 Type
SFP TB5 Type
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized "RMA" number from Atop before shipping
the goods to be repaired to Atop. When in normal use, a sold product shall be replaced
with a new one within 3 months after purchase. The shipping cost from the customer to
Atop will be reimbursed by Atop.
After 3 months and still within the warranty period, it is up to Atop whether to replace the
unit with a new one; normally, as long as a product is under warranty, all parts and labor
are free of charge to the customers.
After the warranty period, the customer shall cover the cost for parts and labor.Three
months after purchase, the shipping cost from the customer to Atop will not be
reimbursed, but the shipping cost from Atop to the customer will be paid by Atop.
Caution
The SFP slot should be used in conjunction with a MSA compliant optical transceiver.
Power Requirements
■ Power input: 12-48VDC, 0.65A max. (No PoE)
■ Relay output: Relay Output with current carrying capacity of 1A@30 VDC,
(Normal Open)
■ PoE PD: 48VDC, 8W max.
All circuit shall be connected to SELV circuit.
Limited Liability
Atop shall not be held responsible for any consequential losses from using Atop’s
product.
Product Categories
Warranty
Product Categories
DIN-Rail Power Supplies
Power Adaptors
Antennas
Other Accessories
Warranty
Top View
Bottom View
Ethernet Switches
Wireless
Serial Device Servers
Protocol Gateways
Media Converters
Embedded Device Servers
10/100/1000 BASE-T(X) Ethernet, PoE and RS-232
Field Maintenance and Service
If the device requires servicing of any kind, you may need to disconnect and
remove it from its mounting. The initial installation should be done in a way that
makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables. Be
RJ-45
1
8
10/100BASE-T(X)
Pin
Signal
Pin
1
Tx+
1
2
Tx -
2
BI_DA-
3
Rx+
4
5
6
Rx -
7
8
careful when handing the so as to not trip over
■ Do not under any circumstance insert foreign objects of any kind into the heat
dissipation holes located in the different faces of the device. This may not only
harm the internal layout but might cause harm to you as well.
■ Do not under any circumstance open the device for any reason. Please contact
your dealer for any repair needed or follow the instructions on section of your
User’s Manual.
Side View
Rear View
54
30
The warranty certification will not be effective until an authorized stamp issued by
Atop’s overseas agents.
Purchase Date:
Serial Number
/
/
(yyyy/mm/dd)
1000BASE-T
3
4
5
BI_DC-
6
7
8
Signal
BI_DA+
BI_DB+ BI_DC+
BI_DB- BI_DD+ BI_DD-
PoE
Pin
DC
1
V+
2
V+
3
V-
4
V+
5
V+
6
V-
7
V-
8
V-
141,8
1. It is recommend to use at least 20 AWG cable and the cable needs to be
resistant to at least 105°C on the power connector.
2. Torque applied to the Terminal block’s screw should be 4.5 in. lb (0.51 Nm)
3. The device needs to be installed inside a Type 1 housing.
4. The device needs to be installed in an area of pollution degree 2 or less.
5. Clean the device with soft cloth with dry or water
6. If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may not be impaired.
177,8
161,8
145
Attention
Atop Customer Services and Supports
1. Please contact your local dealers or Atop Technical Support Center at the
following numbers.
+ 886-3-550-8137 (Atop Taiwan)
+ 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail account
Web Site:www.atop.com.tw, e-mail:service@atop.com.tw
Web Site:www.atop.com.cn, e-mail:service@atop.com.cn
3. Company Addr: 2F, No. 146, Sec. 1, Tung-Hsing Rd., Jubei, Hsinchu 30261,
Taiwan, R.O.C.
Manufacturer Addr: 1F, No.30 R&D Rd. II, Science-Based Industrial Park,
Hsinchu 30076, Taiwan, R.O.C
─ Any changes to this material will be announced on Atop website. ─
50
113
RS-232 Console
Pin
Signal
1
2
3
Tx
4
GND
5
GND
6
Rx
7
8
12,5
46