7039WWADX601U732U1202-U1022

Description
Rocker Switch, SPDT, Latched, 4A, 30VDC, Solder Terminal, Small Rocker Actuator, Through Hole-right Angle
Categoryswitch    Become warped plate switch   
File Size567KB,14 Pages
ManufacturerAPEM
Environmental Compliance  
Download Datasheet Parametric View All

7039WWADX601U732U1202-U1022 Overview

Rocker Switch, SPDT, Latched, 4A, 30VDC, Solder Terminal, Small Rocker Actuator, Through Hole-right Angle

7039WWADX601U732U1202-U1022 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAPEM
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeSMALL ROCKER
body width7 mm
body height13.2 mm
Body length or diameter16.8 mm
Contact (AC) maximum rated R load6A@125VAC
Maximum contact current (AC)6 A
Maximum contact current (DC)4 A
Contact (DC) maximum rated R load4A@30VDC
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)30 V
Electrical life50000 Cycle(s)
Manufacturer's serial number7000
Installation featuresTHROUGH HOLE-RIGHT ANGLE
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
method of packingBULK
surface mountNO
Switch actionLATCHED
switch functionSPDT
Switch typeROCKER SWITCH
Termination typeSOLDER
Base Number Matches1
7000 series
Rocker and paddle switches
Distinctive features and specifications
Wide variety of actuators
Many mounting styles for panel or PCB
VDE, UL and CSA approved
ELECTRICAL SPECIFICATIONS
• Current/voltage rating with resistive load :
Contact
Silver A
Silver,
gold plated AD
Brass,
gold plated CD
Maximum
3A 250VAC - 6A 125VAC - 4A 30VDC
3A 250VAC - 6A 125 VAC - 4A 30VDC
Gold plating withstands up to 100mA 30VDC.
0,4 VA at 20VAC or DC
Minimum
50mA 10VDC
10mA 50mV
10µA 5V
10mA 50mV
10µA 5V
Level *
III and IV
I to IV
I and II
D
• For inductive, lamp or capacitive loads, consult factory.
• Initial contact resistance : 10 mΩ
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength :
1.000 Vrms 50 Hz min. between terminals
1.500 Vrms 50 Hz min. between poles
1.500 Vrms 50 Hz min. between terminals and frame
• Contact bounce : 2 ms max.
• Electrical life : 50.000 cycles at full load
* For details, see technical information, end of catalogue.
MATERIALS
GENERAL SPECIFICATIONS
• Case : diallylphthalate (DAP) or
high temperature plastic material
(UL94-V0)
• Actuator : polyamide
• Housing : stainless steel or steel
tin plated
• Bracket : steel, tin plated
• Contacts
A
: silver
AD
: silver, gold plated
CD
: brass, gold plated
• Terminal seal : epoxy
• Mechanical life : 100.000 cycles
• Panel thickness : 1 (.039) to 2,5 mm(.098)
• Operating temperature : -40°C to +85°C
AGENCY APPROVALS
EN 61058-1
For VDE, refer to 57000 series.
Availability
: consult factory for details of approved models.
Marking
: to order switches marked UL or CSA, complete appropriate box of
ordering format.
APEM
www.apem.com
D-23
Most EMI problems are related to clock signals.
[size=4][color=#000000][backcolor=white] With the development of technology, the clock frequency of digital signals is getting higher and higher, and the circuit system has put forward higher and high...
Jacktang Analogue and Mixed Signal
Share: AD batch hide component labels
[i=s]This post was last edited by qwqwqw2088 on 2022-9-16 15:19[/i]AD batch hide component numberWhen we draw PCB, sometimes we don't want to see the component label parameters in actual work, which a...
qwqwqw2088 PCB Design
[Xiao Meige SoC] How to view the number of GPIO added on the FPGA side of the SoC FPGA system and use interrupts
Xiao Mei has been working hard to systematically organize the development methods of Intel SoC FPGA. (YY self-entertainment). Problem Description: I was stuck for several years because of the interrup...
小梅哥 Altera SoC
What are the two parts of RFID?
Radio frequency identification (RFID) technology is a contactless automatic identification technology. Its basic principle is to use radio frequency signals and their spatial coupling and transmission...
Jacktang Wireless Connectivity
How to use the virtual serial port VCOM function of J-Link?
Most modern PCs no longer have physical COM ports. However, many hardware setups still use UART for logging, diagnostics, and application control. The alternative is to use a USB device that appears a...
MamoYU Integrated technical exchanges
HD7279A controls digital tube (IAR environment)
/***************************************************************************IAR environment, HD7279A, P4.0~CS, P4.1~CLK, P4.2~DATA, P4,3~KAY,DATA is the serial port data port, the timing diagram is as...
灞波儿奔 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号