1. The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency.
2. 26 channels, NTSC frequency raster: T7 - T13 (7.0MHz to 43.0MHz), 2 – 6 (55.25MHz – 83.25MHz), A – 11 (121.25MHz – 199.25MHz), +50dBmV
flat output level.
3. f
1
= 83.25MHz; V
1
= 50dBmV; f
2
= 109.25MHz; V
2
= 50dBmV; f
TEST
= f
1
+ f
2
= 192.5MHz.
4. f
1
= 187.25MHz; V
1
= V
0
; f
2
= 194.25MHz; V
2
= V
1
- 6dB; f
3
= 196.25MHz; V
3
= V
1
- 6dB; f
TEST
= f
1
+ f
2
- f
3
= 185.25MHz according to DIN45004B.
Composite Second Order (CSO) - The CSO parameter (both sum and difference products) is defined by the NCTA.
Composite Triple Beat (CTB) - The CTB parameter is defined by the NCTA.
Cross Modulation (XMOD) - Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the
carrier being tested.
RF Micro Devices Inc. 7628 Thorndike Road, Greensboro, NC 27409-9421
For sales or technical support, contact RFMD at +1.336.678.5570 or
customerservice@rfmd.com.
DS140205
The information in this publication is believed to be accurate. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents or other rights of
third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended
application circuitry and specifications at any time without prior notice.
2 of 3
R2005240P12
Package Drawing
(Dimensions in millimeters)
I
U
123 5 7 89
E
J
S
T
P
K
C
M
R
O
Q
ø
G
N
D
H
L
Nominal
B
0
5 10mm
scale
Min
44,4
Max
44,8
13,8
20,9
8,15
12,75
38,3
4,2
4,2
25,6
-
4,4
27,4
12,1
6,2
0,27
0,48
2,84
3,04
2,79
5,33
5,33
F
A
A
B
C
D
E
44,6
13,6
20,4
8
12,6
38,1
4
4
± 0,2
± 0,2
± 0,5
13,4
44,4
19,9
7,85
12,45
37,9
3,95
3,8
25,2
-
4,0
27,0
11,1
5,4
0,23
0,42
2,24
2,04
2,29
4,83
4,83
± 0,15
± 0,15
± 0,2
Notes:
European
Projection
F
G
H
I
J
K
L
M
+0,2 / -0,05
± 0,2
± 0,2
25,4
4,2
UNC 6-32
± 0,2
± 0,2
± 0,5
27,2
11,6
5,8
0,25
0,45
2,54
2,54
2,54
5,08
5,08
Pinning:
Pin
1
2-3
4
5
6
7-8
9
GND
Output
+VB
N
Name
Input
GND
± 0,4
± 0,02
± 0,03
± 0,3
± 0,5
± 0,25
± 0,25
± 0,25
O
P
Q
R
S
T
U
RF Micro Devices Inc. 7628 Thorndike Road, Greensboro, NC 27409-9421
For sales or technical support, contact RFMD at +1.336.678.5570 or
customerservice@rfmd.com.
DS140205
The information in this publication is believed to be accurate. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents or other rights of
third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended
application circuitry and specifications at any time without prior notice.