EEWORLDEEWORLDEEWORLD

Part Number

Search

4303.2514.04

Description
Mains Power Connector, 10A, 250VAC, Male, Quick Connect Terminal
CategoryThe connector    The connector   
File Size122KB,3 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

4303.2514.04 Overview

Mains Power Connector, 10A, 250VAC, Male, Quick Connect Terminal

4303.2514.04 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
Reach Compliance Codecompliant
Other featuresSTANDARD: IEC 60320-1/C14, 94V-0
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings10A, 250VAC
Manufacturer's serial numberKEC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeQUICK CONNECT
Total number of contacts3
Base Number Matches1
POWER ENTRY MODULES /
GERÄTESTECKER-KOMBIELEMENTE
Power entry module Type KEC
– Panel mount: screw-on version, front or rear-side / snap-in
version, front-side
– 3 functions: appliance inlet, fuseholder with
interchangeable fuse drawer for 5 x 20 or 6,3 x 32 mm
fuses, with or without voltage selector (step switch)
– Version with line filter/shield see page 110
KEC
Fuse drawer
Standard or
Medical
Fuse drawer
50
75
100
Socket
Characteristics
• Versions available with or without internal connections
• The fuse drawer “Fingergrip” can be removed by hand
• For added safety “Extra-Safe” fuse drawers are available
Extra-safe fuse drawers satisfy international standards for medical
equipment. The drawer can only be removed with the aid of a tool
• The fuseholder is accessible from the equipment front
• Qualified for use in equipment according to IEC/EN 60950
Technical data
Rated voltage
Rated currents
250 VAC
10 A; VDE, SEV, Semko
13 A; UL
16 A; CSA 1-pole
10 A; CSA 2-pole
> 3 kV between L-N
> 4 kV between L/N-PE
Dielectric strength
(50 Hz, 1 Min.)
Allowable ambient air
temperatures T
a
–25 °C to + 70 ºC
Degree of protection (front side) IP40 acc. to IEC 60529
Protection class
suitable for equipment with prot. cl. l,
acc. to IEC 61140
Terminals
quick-connect 4,8 x 0,8 mm/tin-plated
Panel thickness s
screw-on: max. 8 mm
snap-in: 1,5/2/2,5 mm
Materials: Housing
Thermoplastic, black, UL94 V-0
Appliance-inlet
acc. to IEC/EN 60320-1/C14,
protection class I,
pin-temperature 70 °C
(cold condition)
1- or 2-pole, shocksafe category PC2
acc. to IEC/EN 60127-6, for
fuse-links 5 x 20 or 6,3 x 32 mm
5 x 20: 2,5 W (1-pole)/2 W (2-pole) per p.
6,3 x 32: 3,15 W (1-pole)/2,5 W (2-pole)
per pole
see derating curves. Take note of the
information on page 195
optional,
step switch, 2–4 positions
Fuseholder
Rated power acceptance at
ambient air temp. T
a
23 ºC
Admissible power acceptance
at higher T
a
Voltage selector
www.schurter.com
53
The signal strength of the mobile phone is -109dbm, 31asu--- Why is dBm a negative value? -100dbm and -120dbm, which signal is stronger?
The signal strength of a mobile phone is -109dbm, 31asu--- Why is dBm a negative value? -100dbm and -120dbm, which signal is stronger? What does 31asu mean?...
QWE4562009 Test/Measurement
Micrometer based on TI MSP430 microcontroller
...
火辣西米秀 Microcontroller MCU
What is eSIM? What are the key advantages of eSIM for IoT? Truphone experts will answer your questions for free!
eSIM (also known as eUICC) is the next generation of SIM card technology. It evolves the traditional SIM card from a limited "one network" capacity to a smart, rewritable and network-agnostic module. ...
eric_wang Sensor
The east-west direction of the compass is reversed
On the Compass and level app I created, I found that the compass needle was pointing to the west when it should be pointing to the east.Below are two pictures showing the difference in direction betwe...
liangtom125 ST MEMS Sensor Creative Design Competition
Looking for a serial port assistant that can send commands alternately and supports 2400 baud rate
As the title says, I need help finding a serial port assistant that can send commands alternately and supports 2400 baud rate I have a device that can send commands alternately, but it doesn't support...
sint27 MCU
Registration for the first half of 2019 software exam is now open
[i=s]This post was last edited by yilonglucky on 2019-3-12 11:11[/i] The National Computer Technology and Software Professional Technical Qualification (Level) Examination is now open for online regis...
yilonglucky Talking about work

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号