Parameter NameAttribute value
package instruction,
Reach Compliance Codeunknown
JESD-30 codeO-XXSS-P3
Number of functions1
Number of terminals3
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeROUND
Package formSPECIAL SHAPE
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal formPIN/PEG
Terminal locationUNSPECIFIED
Base Number Matches1
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced TRIGARD
®
Approximately 8 mm diameter, 11 mm long
UL Recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Aircraft and military electronics
2026 Series - 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
(1)
100 V/μs
1000 V/μs
(1)
Model No.
2026-07
75 V
275 V
700 V
2026-09
90 V
275 V
600 V
2026-15
150 V
350 V
575 V
2026-20
200 V
425 V
625 V
2026-23
230 V
450 V
650 V
2026-25
250 V
475 V
700 V
2026-26
260 V
475 V
700 V
Model No.
2026-30
300 V
550 V
775 V
ribution.
2026-35
350 V
625 V
875 V
2026-40
400 V
675 V
925 V
2026-42
420 V
725 V
1000 V
2026-47
470 V
800 V
1100 V
2026-60
600 V
925 V
1250 V
Impulse Transverse Delay.............................................1000 V/μs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
10
Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
(2)
...............................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20
μs
(3)
.................................................. 1 operation minimum
20000 A, 8/20
μs
...................................................... > 10 operations
5000 A, 10/350
μs
................................................... 1 operation
1000 A, 10/1000
μs
................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles
(3)
............................................. 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Moisture Sensitivity Level ............................................................................................................................... 1
............................................................................................................................... 6
An optional Switch-Grade Fail-Short device is available. The optional Fail-Short assembly will activate at a temperature of 215 °C – 217 °C
to provide a high conductive path to ground in case of a thermal overload. GDTs equipped with the optional Fail-Short device should be
soldered either manually at a temperature that is below the activation temperature of the Fail-Short mechanism, or using a selective soldering
process that does not exceed 210 °C.
Notes:
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >108
Ω
(-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
(2)
(3)
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
WARNING Cancer and Reproductive Harm
www.P65Warnings.ca.gov
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice. Users should verify actual device performance in their specific
applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the
last page of this document, and at
www.bourns.com/docs/legal/disclaimer.pdf.
Description of the implementation process of the 2019 National Undergraduate Electronic Design Competition
Entrusted by the Department of Higher Education of the Ministry of Education and the Department of Personnel and Education of the Ministry of Industry and Information Technology, the National Undergra...
okhxyyo Electronics Design Contest
Why is the IRQ pin of PN532 useless?
Shouldn't the PN532's IRQ pin generate an interrupt when a card is received? I'm using the serial port mode, but why is it that even though I set the IRQ pin to be enabled, it doesn't work? I can read...
sky999 RF/Wirelessly
Half the size, twice the power! - Gallium nitride technology revolutionizes robotics, renewable energy, telecommunications and more
[align=left][color=rgb(85, 85, 85)][font="][size=14px][color=rgb(170, 102, 102)][url=https://e2echina.ti.com/cfs-file/__key/communityserver-blogs-components-weblogfiles/00-00-0 0-01-15/4645.102418_5F0...
alan000345 TI Technology Forum
[NXP Rapid IoT Review] Sensor data reading and display
[i=s] This post was last edited by shihuntaotie on 2019-1-9 21:39 [/i] [font=宋体][size=4] Read all sensor data of the kit according to the evaluation plan, and still use the online IDE for programming....
shihuntaotie RF/Wirelessly
100 sets of Pingtouge RVB2601 RISC-V boards are coming in the new year, bring creativity~
Attention, friends on the road, at work, and at home, Pingtou Ge's 100 sets of RISC-V ecological development board RVB2601 are worth 390 yuan. The New Year is coming. Submit your ideas now and you wil...
EEWORLD社区 Domestic Chip Exchange
Capsizing in the gutter - copper pouring is risky
I was in a rush to deliver goods. I didn’t have time for the sample. I just made a small batch and poured copper. I made a mistake in a hurry. The ground terminal of the Kelvin sampling was poured. Wh...
PowerAnts PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号