Automatic water supply control circuit 3 for simultaneous monitoring of water tower and reservoir

Source: InternetPublisher:supremeOne Keywords: Control circuit BSP transistor Updated: 2021/12/27

29. Automatic water supply<strong>Control circuit</strong>Part 3 for simultaneous monitoring of water tower and reservoir.gif

The electronic control part of the circuit is shown in Figure 11-29. It consists of an inverter (VT±) and a negative NAND gate circuit (VT2,
VT3). The main circuit and control circuit are the same as Figure 11-27 (a).
  This circuit uses two DC power supplies (-12V, -6V). The -6V power supply is used to make the emitters of transistors VT1 ~ VT3 in reverse bias (with a certain positive voltage) when
there is no signal input, so as to obtain Reliable depth cut-off prevents
malfunctions and improves the reliability of the automatic control device.