Home > Control Circuits > One of the zero-trigger thyristor power adjustment circuits

One of the zero-trigger thyristor power adjustment circuits

Source: InternetPublisher:张小哥 Keywords: Thyristor trigger Updated: 2020/01/28

49. One of the zero<strong>trigger</strong><strong>thyristor</strong>power adjustment<strong>circuit</strong>s.gif

The output waveform of the thyristor zero trigger circuit is a sine wave, so it does not produce electromagnetic interference like the phase shift trigger circuit
.

This is the basic circuit for zero trigger thyristor power regulation . In the figure, the voltage regulator tube VS acts as a clamp and provides a path for charging the capacitor Ci; the function of VD is to prevent the capacitor Cz from reverse charging during the negative half cycle of the power supply; the resistors Rz and R4 are current-limiting resistors to limit the control electrode current. In the figure, the power-on time 1 and the power-off time 2 depend on the opening and closing time of the switch (or control contact) SA. That is, the load power is controlled by SA .