Lifter brake control circuit
Source: InternetPublisher:同住地球村 Keywords: Brake control circuit BSP motor short circuit protection Updated: 2021/05/17
The braking circuit of the cargo crane is as shown in the figure.
The overload and short-circuit protection of the circuit uses thermal relays
, temperature relays (Kt) and fuses; the short-circuit protection of motor
MJ uses automatic switch QF (with short-circuit
trip coil); the relay itself has a voltage loss protection
function , using the damper switch SF Realize
the protection of air supply stop.
Protection against free fall of goods: When one of the contactors
KM4, KM5, KM6 is disconnected, the time
relay KTs loses power, and its delayed closing normally open contact
opens after a certain delay (about 0.5s), and the system When the dynamic contactor
KMr loses power, it is released, and its normally open contact is disconnected. When the electromagnetic
brake YA loses power, it brakes the motor to prevent the goods
from falling . The function of KTs is that the motor speed
cannot drop immediately after a sudden power outage, and it is not appropriate to brake it
immediately .
- Design of hydroponic farm based on IoT
- How to design a health emergency alert device using MPU6050
- Secret code lock circuit
- Smart transmitter circuit diagram with hart interface
- Two-channel SL320 level indication circuit
- SCR control buzzer circuit
- Remote control fan speed regulator circuit
- Light controlled electronic bird circuit
- Wire break tester
- Automobile fuel tank level measurement circuit
- electromagnetic field sensor
- Self-defense anti-riot circuit
- Bone hyperplasia treatment circuit
- Electronic anti-asthma circuit
- High-efficiency speaker circuit for rural stage
- Rural vegetable greenhouse lighting circuit
- Particle clogging alarm circuit of wheat seeder
- Frequency modulator composed of NE566
- Multi-frequency resonant high-frequency power amplifier circuit for transmitter stage
- Wireless microphone circuit