DC voltmeter and ammeter connection circuit
Source: InternetPublisher:走马观花 Keywords: Voltmeter ammeter DC voltage Updated: 2020/10/30
When measuring the voltage and current of a certain branch, in addition to correctly selecting
the specifications, accuracy and range of the current and voltmeters according to technical requirements, the ammeter and voltmeter should also be connected to
the correct position in the circuit
during wiring. Improper instrument wiring will also cause large measurement errors. For example, when measuring
the current and voltage of the branch in the figure, there are two ways to connect the voltmeter in the line
, such as point A and point B in the figure. At A, the reading of the ammeter is the current
value flowing through the wind, and the reading of the voltmeter contains not only the voltage of the island, but also the voltage value at both ends of the ammeter.
Therefore, the reading of the voltmeter is larger than the actual value. It is obvious that when R. When the internal resistance of the voltmeter is much larger than the internal resistance of the ammeter
, the voltmeter should be connected at point A; when the internal resistance of the voltmeter is much larger than the resistance of the ammeter
, the voltmeter should be connected at point B. During actual measurement, the resistance of a certain branch is often unknown
. Therefore, the position of the voltmeter during measurement can be selected experimentally. When measuring, you can try it at two points A and B respectively. If
there is little or no difference in the readings of the voltmeter between the two connection methods, it can be connected to point A; if there is little or no difference in the readings of the ammeter in the two connection methods,
it can be connected to point B; if If the readings of the ammeter and voltmeter are the same between the two connection methods , the voltmeter can be connected to point A or point B. .
- DIY Multimeter High Frequency Signal Probe
- Design of wireless meter reading system based on DSP
- Using NE555 to make diode and triode detector
- Multi-speed current test circuit of transistor HFE
- Leakage Tester
- An electronic load meter using LM324 operational amplifier as the main control device
- Test of leakage current of switching appliances
- DT8 type 5A current mutual induction three-phase four-wire active energy meter wiring
- High current, high power amplifier circuit
- Tachometer, single pulse generator, power loss detector, peak detector circuit diagram
- LED lighting display detection circuit with overload protection
- Capacitive proximity sensing detection circuit
- Bus door status detection circuit
- Three-phase AC power supply phase sequence detection circuit
- Gas concentration sensing detection circuit
- Light detection circuit with current output
- Tape head detection circuit
- pH value detection circuit
- Film thickness detection circuit using eddy current method
- Direct heating gas-sensitive bridge detection circuit