Working principle of the circuit: After the voltage of 380 V is reduced to a low voltage of 6.3 V by the transformer T, it
is converted from VD. ~VD. After full-wave rectification and C2 filtering, the working voltage is provided for the base time circuit NE555
; when the water level drops below the sun, pin 2 of NE555 is at low potential , and its internal trigger
circuit flips, and pin 3 outputs high level, and the relay K Get electric action, double knife contact
K. 1. The closed motor is started to pump water, and at the same time K. : closed, the wiring at point C is
short-circuited; when the water level rises to point A, the power supply voltage passes through R. , 4, and four points make the potential of pins 2 and 6 of
NE555 rise to high potential . Pin 6 is the high trigger end of the time base circuit. When
its voltage value reaches 2/3 VOD, the internal circuit flips over, causing the output of pin 3 to turn to
low level, and K loses power and releases Ki_,, K. 1: The motor stops working, the BC connection contact
jumps open, the AB connection is short-circuited, and the circuit enters the waiting state. When the water level is lower than point A
but higher than the mouth point, press button K2 to manually fill the water tank.


EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号