Home > Control Circuits >Motor Control > Forward and reverse operation energy consumption braking circuit 3

Forward and reverse operation energy consumption braking circuit 3

Source: InternetPublisher:newlandmark Keywords: Energy consumption braking braking circuit BSP electric motor Updated: 2020/10/24

146. Forward and reverse operation<strong>Energy consumption braking</strong>Circuit 3.gif

 The circuit is shown in Figure 3-146. This line eliminates the need for a step-down transformer and uses the principle of capacitor energy storage and discharge to achieve braking. It can be used for motors
with infrequent starts and stops and a power of less than 1kW .     When stopping, the contactor KMi (or KM2) is released, and the capacitor C discharges to the motor stator winding, thereby generating braking torque and stopping the motor quickly.