1. On-site requirements: PLC acts as a controller and instrument equipment acts as an execution device. The execution device can respond to the instructions from the PLC in real time and feed back data to the PLC, so that the PLC can control and monitor the instrument equipment and realize precise control of the production process.
2. Solution: Through the connection of Batu Automation Modbus protocol to Profinet protocol gateway module (BT-MDPN100), PLC or controller can realize remote monitoring and data transmission of instrument equipment, improving production efficiency and operation stability. Modbus protocol to Profinet protocol gateway module serves as a bridge to connect devices, converting communications between different protocols to make the information flow of the entire system smoother.
Batu Automation Modbus protocol to PN gateway module
3. Functions and advantages: The main function of the Batu Automation Modbus protocol to Profinet protocol gateway module (BT-MDPN100) is to realize the conversion and communication between the Modbus protocol and the Profinet protocol. The Modbus protocol to Profinet protocol gateway module integrates two protocols, Modbus and Profinet, supports Modbus RTU master/slave, and can be connected to RS485 interface devices. It has its own network port and serial port, which can realize both protocol conversion and interface conversion.
Batu Automation Modbus protocol to PN gateway module
4. Taking TIA Portal as an example, the gateway configuration process is described in detail below
1. Open TIA Portal, create a new project, and modify the IP address.
Batu Automation Modbus protocol to PN gateway module
2. Load the provided GSD file
Batu Automation Modbus protocol to PN gateway module
3. Find the gateway driver, double-click or drag and add it to the TIA Portal
Batu Automation Modbus protocol to PN gateway module
4. Configure the gateway IP address. Please note that the IP addresses of the three (PLC, gateway, and local machine) should be on the same network segment, otherwise the communication will not be able to be connected normally.
Batu Automation Modbus protocol to PN gateway module
5. Connect the gateway to the PLC in the TIA Portal.
Batu Automation Modbus protocol to PN gateway module
6. Open the gateway configuration software, click Profinet in the menu bar, and import the provided GSD file
Batu Automation Modbus protocol to PN gateway module
7. Click the second menu bar and select Modbus RS-485. Note: Except for configuring a 6-channel gateway, you need to configure the communication parameters starting from Modbus 1. For the rest, you need to configure the communication parameters starting from Modbus 3.
Batu Automation Modbus protocol to PN gateway module
8. Click Local IP Configuration in the menu bar, click the drop-down menu of Master-Slave Mode and select Mastor, and keep the rest of the configuration as default.
Batu Automation Modbus protocol to PN gateway module
9. In the menu bar, click Data Mapping, click New Panel, and click Add to add the first slot.
10. Note: Change the slot number to 1, change the Module ID to CH1, and keep the rest as default.
Batu Automation Modbus protocol to PN gateway module
11. Add the second and third slots and other slots, and add read and write instructions according to site needs. Note: The added slots should be consistent with the TIA Portal configuration.
Batu Automation Modbus protocol to PN gateway module
12. Except for the six-channel gateway, the Modbus serial number starts from 3, so this case selects 3
Batu Automation Modbus protocol to PN gateway module
13. Click Configuration Distribution - Connect. The default gateway IP address is 192.168.0.5, and the port remains the default.
Batu Automation Modbus protocol to PN gateway module
14. After the connection is successful, click on the configuration to send. Note: If the configuration is not downloaded successfully, the gateway cannot be searched when TIA Portal assigns the gateway name.
Batu Automation Modbus protocol to PN gateway module
15. Return to TIA Portal and right-click to assign a gateway name
16. Click Update List, select the searched device and click Assign. Click Close when completed.
Batu Automation Modbus protocol to PN gateway module
17. Right-click and select Complete Rebuild of Hardware in Compilation
Batu Automation Modbus protocol to PN gateway module
18. Click the Download button to download the configuration to the gateway: Port subnet connection: Select PNAE_1, click Start Search, select the searched device, click Download, and follow the prompts to complete the download.
Batu Automation Modbus protocol to PN gateway module
19. Create a new monitoring table to monitor the sending and receiving of data, as well as the correctness
Batu Automation Modbus protocol to PN gateway module
In summary, the communication solution between smart instruments and PLCs through the Modbus protocol to Profinet protocol gateway module is an effective solution to optimize industrial control system communication. In this way, the advantages of the Profinet protocol can be fully utilized, the communication efficiency and stability of the system can be improved, and the modernization and upgrading of industrial automation control can be realized.
Previous article:8 Tips to Solve Conducted Interference in EMI
Next article:Batu Automation Profinet protocol to Modbus protocol gateway module connects smart instruments and PLC communications
- Popular Resources
- Popular amplifiers
- "Cross-chip" quantum entanglement helps build more powerful quantum computing capabilities
- Why is the vehicle operating system (Vehicle OS) becoming more and more important?
- Car Sensors - A detailed explanation of LiDAR
- Simple differences between automotive (ultrasonic, millimeter wave, laser) radars
- Comprehensive knowledge about automobile circuits
- Introduction of domestic automotive-grade bipolar latch Hall chip CHA44X
- Infineon Technologies and Magneti Marelli to Drive Regional Control Unit Innovation with AURIX™ TC4x MCU Family
- Power of E-band millimeter-wave radar
- Hardware design of power supply system for automobile controller
Professor at Beihang University, dedicated to promoting microcontrollers and embedded systems for over 20 years.
- Intel promotes AI with multi-dimensional efforts in technology, application, and ecology
- ChinaJoy Qualcomm Snapdragon Theme Pavilion takes you to experience the new changes in digital entertainment in the 5G era
- Infineon's latest generation IGBT technology platform enables precise control of speed and position
- Two test methods for LED lighting life
- Don't Let Lightning Induced Surges Scare You
- Application of brushless motor controller ML4425/4426
- Easy identification of LED power supply quality
- World's first integrated photovoltaic solar system completed in Israel
- Sliding window mean filter for avr microcontroller AD conversion
- What does call mean in the detailed explanation of ABB robot programming instructions?
- RAQ #223: How to measure and determine soft-start timing without a soft-start equation?
- RAQ #223: How to measure and determine soft-start timing without a soft-start equation?
- GigaDevice's full range of automotive-grade SPI NOR Flash GD25/55 wins ISO 26262 ASIL D functional safety certification
- GigaDevice's full range of automotive-grade SPI NOR Flash GD25/55 wins ISO 26262 ASIL D functional safety certification
- New IsoVu™ Isolated Current Probes: Bringing a New Dimension to Current Measurements
- New IsoVu™ Isolated Current Probes: Bringing a New Dimension to Current Measurements
- Infineon Technologies Launches ModusToolbox™ Motor Kit to Simplify Motor Control Development
- Infineon Technologies Launches ModusToolbox™ Motor Kit to Simplify Motor Control Development
- STMicroelectronics IO-Link Actuator Board Brings Turnkey Reference Design to Industrial Monitoring and Equipment Manufacturers
- Melexis uses coreless technology to reduce the size of current sensing devices
- EEWORLD University ---- Amplifier Protection Series
- Introduction to calling DSP functions of TMS320F28335
- Running Debian system on K510 (unsuccessful compilation)
- UWB transceiver DW1000 chip internal diagram
- What RF people must know: A journey of discovery of electromagnetic waves
- Can anyone provide the corresponding Vbe curve of the transistor Vce/Ic amplification, saturation, and cutoff curves?
- If the input signal travels 100 meters, is it better to connect it to the positive pole or the negative pole of the optocoupler?
- Tongzhou Electronics IPO Prospectus
- PADS Rename
- Please teach me the concept of RL78 related timer