Summary of PLC shortcut keys for Siemens/Mitsubishi/Omron

Publisher:RadiantBeautyLatest update time:2024-08-16 Source: elecfansKeywords:Siemens Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

The masters in the field of programming generally rely on keyboards, and shortcut keys are one of their basic skills.

As the saying goes, speed is of the essence. In many cases, the use of shortcut keys can not only save a certain amount of time, but also make everyone more familiar with computer operations, and also make laymen look at you with new eyes.


Today, the editor has collected the shortcut keys for Siemens and Mitsubishi PLCs. Please save a copy for future study.

1 Siemens shortcut keys

Operation content shortcut key
F1 Get Help
F2 Ladder diagram enters edit mode
F3 Ladder diagram enters running mode
Shift+F3 Ladder diagram enters monitoring mode (can be edited online)
F4 Compiling the Program
F5 Normally open contact input
Shift+F5 Parallel normally open contact input
F6 Normally closed contact input
Shift+F6 Parallel normally closed contact input
F7 Coil output
F8 Function command input
F9 Horizontal line input
Shift+F9 Vertical line input
Ctrl+F10 Remove vertical line
Ctrl+Alt+F10 Invert command input
delete Delete the current component and line
Shift+delete Delete the content of the line where the cursor is located
insert The cursor box changes color to rose red, and a single component can be inserted
Shift+insert Insert a row
ALT+F1 Switch to statement list mode
ALT+1 Soft component test (valid in monitoring mode)
Ctrl+F Finding devices and addresses
HOME Move the cursor to the first column of the same row
END Move the cursor to the last column in the same row
PAGE UP Move vertically up one screen
PAGE DOWN Move vertically down one screen
LEFT ARROW Move the cursor one cell to the left
RIGHT ARROW Move the cursor one cell to the right
UP ARROW Move the cursor up one cell
DOWN ARROW Move the cursor down one cell
CTRL + HOME Move the cursor to the first cell of the first network
CTRL + END Move the cursor to the last cell of the last network
CTRL + PAGE UP Display the next POU and move left to browse the POU markers
CTRL + PAGE DOWN Display the next POU and move right to browse the POU markers
TAB When you select an instruction with a Boolean (bit value) parameter, the TAB key moves to the next Boolean parameter in the instruction (FBD only).
SHIFT + PAGE UP Scaling up network options
SHIFT + PAGE DOWN Expanding network selection downward
CONTROL+SHIFT+HOME Expand selection to first network
CONTROL + SHIFT + END Extend selection to last network
CONTROL + SHIFT + END Select All Networks
CTRL+ X SHIFT + DELETE When a network series is selected, cuts the series; when the cursor is on a network title, cuts the entire network grid content
CTRL + C CTRL + INSERT When a network series is selected, copies the series; when the cursor is on a network title, copies the entire network grid content
CTRL + V SHIFT + INSERT When a network series is selected, paste the series; when the cursor is on a network title, paste the network; when the cursor is before/above the current position of the cursor, paste the selection
SPACEBAR Edit the mnemonic or operand of the current cell
ENTER Edit the mnemonic or operand of the current cell
CTRL + LEFT ARROW Drop a horizontal line and move the cursor one cell to the left
CTRL + RIGHT ARROW Drop a horizontal line and move the cursor one cell to the right
CTRL + UP ARROW Drop a vertical line and move the cursor up one cell
CTRL + DOWN ARROW Drop a vertical line and move the cursor down one cell
BACKSPACE Move the cursor one cell to the left and delete the current cell
SHIFT + LEFT ARROW Select the current network and move the cursor one cell to the left
SHIFT + RIGHT ARROW Select the current network and move the cursor one cell to the right
SHIFT + HOME Select the current network and place the cursor at the first cell in the current row
SHIFT + END Select the current network and place the cursor at the last cell in the current row.
SHIFT+DOWN ARROW Select from Current Network
SHIFT + UP ARROW Select from current network upwards
SHIFT + PAGE UP Select a page of adjacent networks from the current network upwards
SHIFT + PAGE DOWN Select a page of adjacent networks from the current network down
Select all adjacent networks from the top
CTRL + SHIFT + HOME From cursor to POU
CTRL + SHIFT + END Select all adjacent networks from the cursor to the bottom of the POU
CTRL + A CTRL + A Select all networks in the POU
CONTROL+SHIFT+HOME Expand selection to first network
CONTROL+ SHIFT+END Extend selection to last network
CTRL + F Finding a String
CTRL + H Replace String
CTRL + F2 Set as bookmark at the current cursor position
CTRL + F3 Insert Network
CTRL + F4 Deleting a network
SHIFT + BACKSPACE Backspace
ALT + BACKSPACE Revocation
SHIFT + TAB Tab backward

2 Mitsubishi shortcut keys

(Operation) Content Shortcut keys (operation)
Create a new project file Ctrl + N
Open the project file Ctrl + O
Save the project file Ctrl + S
Print Ctrl + P
Undo Ladder Cut/Paste Ctrl + Z
Delete the selected content and save it to the clipboard Ctrl + X
copy Ctrl + C
Paste Ctrl + V
Show/Hide Project File Data Alt + 0
Soft component detection Alt + 1
Jump Alt + 2
Local operation Alt + 3
Single step operation Alt + 4
Remote Operation Alt + 6
Project data list Alt + 7
Network parameter settings Alt + 8
Close the active window Ctrl + F4
Move to the window below Ctrl + F6
End the application Alt + F4
Insert Column Ctrl + Ins
Deleting a column Ctrl + Del
Convert the current (editing) program F4
Convert all current (editing) programs Alt + Ctrl + F4
Write (running status) Shift + F4
Show/Hide Annotations Ctrl + F5
Switch to monitor mode/start monitoring F3
Convert to monitor (write mode) Shift + F3
Start monitoring (write mode) Shift + F3
Move the cursor when entering a ladder diagram. Ctrl + Cursor key
Stop monitoring Alt + F3
Insert Row Shift + Ins
Deleting a row Shift + Del
Write Mode F2
Read Mode Shift + F2
Show/Hide Description Ctrl + F7
Show/Hide Annotations Ctrl + F8
Show/Hide Models Alt + Ctrl + F6
Start monitoring. Ctrl + F3
Stop monitoring. Alt + Ctrl + F3
Convert between ladder diagram and instruction list Alt + F1
Find contacts or relay coils Alt + Ctrl + F7
SFC and ladder diagram conversion Ctrl + J
Insert Row Shift + Ins
Deleting a row Shift + Del
Insert Column Ctrl + Ins
Deleting a column Ctrl + Del
Switch to write mode F2
Switch to read mode Shift + F2
Switch to monitor mode/start monitoring F3
Convert to monitor (write mode) Shift + F3
Start monitoring (write mode) Shift + F3
Stop monitoring Alt + F3
Start monitoring all windows. Ctrl + F3
Stop monitoring all windows. Alt + Ctrl + F3
Convert the current editing module F4
Show/Hide Model Name Alt + Ctrl + F6
Convert all current editing programs Alt + Ctrl + F4
Show/Hide Annotations Ctrl + F5
Move SFC cursor Ctrl + Cursor key
Find contacts or coils Alt + Ctrl + F7
Program presentation (MELSAP-L) Alt + Ctrl + F8
Single Step F5
Block start step (with END check) F6
Block start step (no END check) Shift + F6
Jump F8
END step F7
Dummy Step Shift + F5
transmission F5
Select branch F6
Simultaneous branching F7
Select Focus F8
Concentrate at the same time F9
Vertical Lines Shift + F9
Transform properties to normal Ctrl + 1
Changing properties to store coils Ctrl + 2
Changing properties to store operations Ctrl + 3
Changing properties to store operations Ctrl + 4
Change properties to reset Ctrl + 5
Vertical line (editing line) Alt + F5
Select branch (edit line) Alt + F7
Simultaneous branching (editing lines) Alt + F8
Select Concentration (Edit Line) Alt + F9
Simultaneous concentration (editing line) Alt + F10
Deleting a row Ctrl + F9
Block Pause F5
Step Pause F6
Block operation F8
Step operation F7
Single step operation F9
Run all blocks F10
Force block to stop Shift + F8
Forced step stop Shift + F7
Force reset stop Shift + F9
Move to the first row Ctrl + Home
Move to the last row Ctrl + End
Select all text Ctrl + A
Redo Undo Processing Ctrl + Y
Positioned in the specified row Ctrl + J
Search content Ctrl + F
Next search during search F5
Previous search when searching Shift + F5
Replace text string Ctrl + H
Set/Remove Bookmarks Ctrl + F7
Search for next candidate of bookmark F7
Search for bookmarks Shift + F7
Convert the program being edited F4
Convert all programs in editing Alt + Ctrl + F4
Refilling in RUN Shift + F4
Start temporary control of all windows Ctrl + F3
Stop temporary control of all windows Alt + Ctrl + F3
Start control F3
Stop temporary control Alt + F3
Display the label selection screen F11
Display the function selection dialog Shift + F11
Switch the window split up and down, left and right by ST Shift + Tab

[1] [2] [3]
Keywords:Siemens Reference address:Summary of PLC shortcut keys for Siemens/Mitsubishi/Omron

Previous article:Realize data interaction technology between EtherCAT devices and PROFINET controllers
Next article:The three major binocular stereo vision algorithm principles and their code implementation

Recommended ReadingLatest update time:2024-11-16 11:46

How to realize real-time data collection in PLC in the Internet of Things
Data collection and transmission is very important for subsequent enterprise analysis and decision-making, and real-time data collection can improve the overall production awareness, so as to take more timely and efficient measures. Therefore, PLC real-time data collection has become a basic application of enterpris
[Embedded]
Siemens TIA: Application of Memory Indirect Addressing
In STL, the following options are available for indirect addressing: Memory Indirect Addressing Register indirect internal area addressing Register indirect cross-region addressing Memory Indirect Addressing For memory indirect addressing, you store the address in a variable. The varia
[Embedded]
Mitsubishi FX series PLC to Ethernet via CHNet-FX connection Kingview configuration instructions
Mitsubishi FX1S/1N/2N/3S/3G/3GC/3U/3UC series PLC, and Kingview software Ethernet communication. Convert to Ethernet with Xingda Easy Control CHNet-FX 1. Create a new project and open it. 2. Click "COM1", select "New", select "FX3u_16M_Ethernet----TCP" in the pop-up dialog box, and click "Next".
[Embedded]
Mitsubishi FX series PLC to Ethernet via CHNet-FX connection Kingview configuration instructions
TWS solution based on MAXIM PLC technology
In recent years, the overall market of TWS wireless headsets has continued to grow rapidly, and the market has become increasingly popular. At the same time, the continuous improvement and development of smart terminals, Bluetooth technology, and chip technology have further accelerated the popularization of TWS wir
[Embedded]
TWS solution based on MAXIM PLC technology
50 Mitsubishi PLC FAQs
Which PLC can directly replace Mitsubishi FX1N and 2N? Mitsubishi's official website announced that both 1N and 2N have been discontinued. Some of our equipment uses these two models. We want to quickly find a direct replacement for emergency use. Answer: You can choose FX 3U PLC, but before replacing it, you
[Embedded]
50 Mitsubishi PLC FAQs
Four methods of cross-segment communication between PLCs
1. Implemented through routing mode If two PLCs belong to different network segments and have data communication needs, the most typical application is to achieve it through routing mode. On the PLC side, you need to enable the "use router" function, fill in the corresponding gateway address, and then call the
[Embedded]
Four methods of cross-segment communication between PLCs
Several ways to write one-button start and stop of Siemens SMART200PLC
In production, due to factors such as installation environment, cost control, and ease of operation, one-button start and stop control will be used, such as motor control, valve control, etc. Today I will talk to you about several common writing methods. For the sake of intuitiveness and popularity, we use LAD (ladd
[Embedded]
Several ways to write one-button start and stop of Siemens SMART200PLC
The process of converting traditional electrical diagrams into PLC ladder diagrams
PLC programming generally adopts the intuitive method, that is, it is based on the learning experience of the circuit designer himself, which is more subjective and direct. It is necessary to go through a period of trial and error, and debug the program before it can meet the required functions or action requirement
[Embedded]
The process of converting traditional electrical diagrams into PLC ladder diagrams
Latest Embedded Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号